INT TECHNICS Industrial Automation Partner
  • About us
  • Select brand
    ABB BANNER Baumer BECKHOFF Danfoss ifm INNOMOTICS Keyence Murrelektronik OBO Omron Pepperl+Fuchs Phoenix Contact PILZ Schneider Electric SICK SIEMENS Telemecanique Turck Weidmüller WEINTEK Yaskawa
  • Contacts
  • English En English
    English Deutsch Español Polski
  • Add to RFQ RFQ
  1. Catalog
  2. SICK
  3. Distance Sensors
  4. Short range distance sensors (displacement)
Short range distance sensors (displacement) DT10 DT2 DT20 DT20 Hi OD Hi OD Max OD Mini OD Precision OD Value

Short range distance sensors (displacement) Items 1 - 96 of 176 ⍾ SICK ⍾ Last modified May 28, 2026

Catalog up DT10 DT2 DT20 DT20 Hi OD Hi OD Max OD Mini OD Precision OD Value

Short range distance sensors (displacement) ⍾ Page 1

  • « Previous page
  • 1
  • 2
  • » Next page
  • SICK AOD5-N1 (6035984)
    Product details Add to RFQ Add to RFQ

    AOD5-N1

    OD Precision, RS-232USB. Data interface: 3 x -10 ... +10 V (≥ 10 kΩ), 3 x 4 mA ... 20 mA (≤ 300 Ω), RS-232, USB. Connection type: Terminal board. Housing material: Polycarbonat and …

  • SICK AOD5-P1 (6035985)
    Product details Add to RFQ Add to RFQ

    AOD5-P1

    OD Precision, RS-232USB. Data interface: 3 x -10 ... +10 V (≥ 10 kΩ), 3 x 4 mA ... 20 mA (≤ 300 Ω), RS-232, USB. Connection type: Terminal board. Housing material: Polycarbonat and …

  • SICK AODG-N1 (6030979)
    Product details Add to RFQ Add to RFQ

    AODG-N1

    OD Max, RS-232. Data interface: 2 x -5 ... +5 V (≥ 1 kΩ), 2 x 4 mA ... 20 mA (≤ 300 Ω), RS-232. Connection type: Terminal board. Housing material: Polycarbonat and nylon 66.

  • SICK AODG-P1 (6030978)
    Product details Add to RFQ Add to RFQ

    AODG-P1

    OD Max, RS-232. Data interface: 2 x -5 ... +5 V (≥ 1 kΩ), 2 x 4 mA ... 20 mA (≤ 300 Ω), RS-232. Connection type: Terminal board. Housing material: Polycarbonat and nylon 66.

  • SICK AOD-N1 (6028961)
    Product details Add to RFQ Add to RFQ

    AOD-N1

    OD Max, RS-232. Data interface: 2 x -5 ... +5 V (≥ 1 kΩ), 2 x 4 mA ... 20 mA (≤ 300 Ω), RS-232. Connection type: Terminal board. Housing material: Polycarbonat and nylon 66.

  • SICK AOD-P1 (6028960)
    Product details Add to RFQ Add to RFQ

    AOD-P1

    OD Max, RS-232. Data interface: 2 x -5 ... +5 V (≥ 1 kΩ), 2 x 4 mA ... 20 mA (≤ 300 Ω), RS-232. Connection type: Terminal board. Housing material: Polycarbonat and nylon 66.

  • SICK DT10-N10B5 (1027327)
    Product details Add to RFQ Add to RFQ

    DT10-N10B5

    DT10. Data interface: 4 mA ... 20 mA (≤ 200 Ω). Typ. light spot size (distance): 20 mm x 20 mm (at 400 mm). Resolution: 1.5 mm, 6 % ... 90 % remission. Measuring range: 50 mm ... 5 …

  • SICK DT10-N10D5 (1027328)
    Product details Add to RFQ Add to RFQ

    DT10-N10D5

    DT10. Data interface: 4 mA ... 20 mA (≤ 200 Ω). Typ. light spot size (distance): 20 mm x 20 mm (at 400 mm). Resolution: 1.5 mm, 6 % ... 90 % remission. Measuring range: 50 mm ... 4 …

  • SICK DT10-P10B5 (1027325)
    Product details Add to RFQ Add to RFQ

    DT10-P10B5

    DT10. Data interface: 4 mA ... 20 mA (≤ 200 Ω). Typ. light spot size (distance): 20 mm x 20 mm (at 400 mm). Resolution: 1.5 mm, 6 % ... 90 % remission. Measuring range: 50 mm ... 4 …

  • SICK DT10-P10D5 (1027326)
    Product details Add to RFQ Add to RFQ

    DT10-P10D5

    DT10. Data interface: 4 mA ... 20 mA (≤ 200 Ω). Typ. light spot size (distance): 20 mm x 20 mm (at 400 mm). Resolution: 1.5 mm, 6 % ... 90 % remission. Measuring range: 50 mm ... 4 …

  • SICK DT20-N130B0960 (1029274)
    Product details Add to RFQ Add to RFQ

    DT20-N130B0960

    DT20. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Typ. light spot size (distance): 15 mm x 15 mm (at 1 m). Resolution: 1 mm / 2 mm. Measuring range: 90 mm ... 600 mm, 18 % ... 90 …

  • SICK DT20-N130B1000 (1029275)
    Product details Add to RFQ Add to RFQ

    DT20-N130B1000

    DT20. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Typ. light spot size (distance): 15 mm x 15 mm (at 1 m). Resolution: 1 mm / 2 mm. Measuring range: 100 mm ... 1,000 mm, 18 % ... …

  • SICK DT20-N214B (1040140)
    Product details Add to RFQ Add to RFQ

    DT20-N214B

    The DT20 Hi/DT20-N214B is a laser distance sensor featuring a digital output of 1 x NPN and a current analog output. It offers a measuring range from 100 mm to 600 mm with a linear …

  • SICK DT20-N224B (1044216)
    Product details Add to RFQ Add to RFQ

    DT20-N224B

    The DT20 Hi series laser distance sensor, model DT20-N224B, offers a measurement range of 100 mm to 1,000 mm. It features a current analog output and a typical light spot size of 6 …

  • SICK DT20-N244B (1040713)
    Product details Add to RFQ Add to RFQ

    DT20-N244B

    DT20 Hi. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 1 mm. Typ. light spot size (distance): 3 mm x 6 mm (300 mm). Resolution: 0.2 mm. Measuring range: 100 mm ... 300 …

  • SICK DT20-N254B (1041279)
    Product details Add to RFQ Add to RFQ

    DT20-N254B

    DT20 Hi. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 0.5 mm. Typ. light spot size (distance): 2 mm x 4 mm (150 mm). Resolution: 0.1 mm. Measuring range: 50 mm ... 15 …

  • SICK DT20-P130B0925 (1041759)
    Product details Add to RFQ Add to RFQ

    DT20-P130B0925

    DT20. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Typ. light spot size (distance): 15 mm x 15 mm (at 1 m). Resolution: 1 mm / 2 mm. Measuring range: 90 mm ... 250 mm, 18 % ... 90 …

  • SICK DT20-P130B0960 (1029273)
    Product details Add to RFQ Add to RFQ

    DT20-P130B0960

    DT20. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Typ. light spot size (distance): 15 mm x 15 mm (at 1 m). Resolution: 1 mm / 2 mm. Measuring range: 90 mm ... 600 mm, 18 % ... 90 …

  • SICK DT20-P130B1000 (1028800)
    Product details Add to RFQ Add to RFQ

    DT20-P130B1000

    DT20. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Typ. light spot size (distance): 15 mm x 15 mm (at 1 m). Resolution: 1 mm / 2 mm. Measuring range: 100 mm ... 1,000 mm, 18 % ... …

  • SICK DT20-P130B1025 (1029922)
    Product details Add to RFQ Add to RFQ

    DT20-P130B1025

    DT20. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Typ. light spot size (distance): 15 mm x 15 mm (at 1 m). Resolution: 1 mm / 2 mm. Measuring range: 100 mm ... 250 mm, 18 % ... 9 …

  • SICK DT20-P130B1050 (1027831)
    Product details Add to RFQ Add to RFQ

    DT20-P130B1050

    DT20. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Typ. light spot size (distance): 15 mm x 15 mm (at 1 m). Resolution: 1 mm / 2 mm. Measuring range: 100 mm ... 500 mm, 18 % ... 9 …

  • SICK DT20-P130B1070S01 (1040638)
    Product details Add to RFQ Add to RFQ

    DT20-P130B1070S01

    DT20. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Typ. light spot size (distance): 15 mm x 15 mm (at 1 m). Resolution: 2 mm. Measuring range: 100 mm ... 700 mm, 6 % ... 90 % remi …

  • SICK DT20-P130B1080 (1028720)
    Product details Add to RFQ Add to RFQ

    DT20-P130B1080

    DT20. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Typ. light spot size (distance): 15 mm x 15 mm (at 1 m). Resolution: 1 mm / 2 mm. Measuring range: 100 mm ... 800 mm, 18 % ... 9 …

  • SICK DT20-P130B2070 (1047102)
    Product details Add to RFQ Add to RFQ

    DT20-P130B2070

    DT20. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Typ. light spot size (distance): 15 mm x 15 mm (at 1 m). Resolution: 1 mm / 2 mm. Measuring range: 200 mm ... 700 mm, 18 % ... 9 …

  • SICK DT20-P130B2535 (1028721)
    Product details Add to RFQ Add to RFQ

    DT20-P130B2535

    DT20. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Typ. light spot size (distance): 15 mm x 15 mm (at 1 m). Resolution: 1 mm / 2 mm. Measuring range: 250 mm ... 350 mm, 18 % ... 9 …

  • SICK DT20-P130B2545 (1028724)
    Product details Add to RFQ Add to RFQ

    DT20-P130B2545

    DT20. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Typ. light spot size (distance): 15 mm x 15 mm (at 1 m). Resolution: 1 mm / 2 mm. Measuring range: 250 mm ... 450 mm, 18 % ... 9 …

  • SICK DT20-P130B2560 (1028723)
    Product details Add to RFQ Add to RFQ

    DT20-P130B2560

    DT20. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Typ. light spot size (distance): 15 mm x 15 mm (at 1 m). Resolution: 1 mm / 2 mm. Measuring range: 250 mm ... 600 mm, 18 % ... 9 …

  • SICK DT20-P130B2570 (1040008)
    Product details Add to RFQ Add to RFQ

    DT20-P130B2570

    DT20. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Typ. light spot size (distance): 15 mm x 15 mm (at 1 m). Resolution: 1 mm / 2 mm. Measuring range: 250 mm ... 700 mm, 18 % ... 9 …

  • SICK DT20-P130B3000 (1029970)
    Product details Add to RFQ Add to RFQ

    DT20-P130B3000

    DT20. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Typ. light spot size (distance): 15 mm x 15 mm (at 1 m). Resolution: 1 mm / 2 mm. Measuring range: 300 mm ... 820 mm, 18 % ... 9 …

  • SICK DT20-P130B4000 (1028722)
    Product details Add to RFQ Add to RFQ

    DT20-P130B4000

    DT20. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Typ. light spot size (distance): 15 mm x 15 mm (at 1 m). Resolution: 1 mm / 2 mm. Measuring range: 400 mm ... 1,000 mm, 18 % ... …

  • SICK DT20-P130B4080 (1041497)
    Product details Add to RFQ Add to RFQ

    DT20-P130B4080

    DT20. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Typ. light spot size (distance): 15 mm x 15 mm (at 1 m). Resolution: 1 mm / 2 mm. Measuring range: 400 mm ... 800 mm, 18 % ... 9 …

  • SICK DT20-P130B6009 (1042361)
    Product details Add to RFQ Add to RFQ

    DT20-P130B6009

    DT20. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Typ. light spot size (distance): 15 mm x 15 mm (at 1 m). Resolution: 1 mm / 2 mm. Measuring range: 90 mm ... 600 mm, 18 % ... 90 …

  • SICK DT20-P214B (1040012)
    Product details Add to RFQ Add to RFQ

    DT20-P214B

    The DT20 Hi series laser distance sensor, model DT20-P214B, provides precise distance measurement with a digital PNP output and current analog output. Its measuring range is 100 mm …

  • SICK DT20-P214BS03 (1051547)
    Product details Add to RFQ Add to RFQ

    DT20-P214BS03

    DT20 Hi. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 2 mm. Typ. light spot size (distance): 3 mm x 6 mm (600 mm). Resolution: 0.5 mm. Measuring range: 100 mm ... 600 …

  • SICK DT20-P224B (1040405)
    Product details Add to RFQ Add to RFQ

    DT20-P224B

    The DT20 Hi series laser distance sensor, model DT20-P224B, provides reliable distance measurement for industrial applications. It features a digital PNP output and a current analo …

  • SICK DT20-P244B (1040406)
    Product details Add to RFQ Add to RFQ

    DT20-P244B

    DT20 Hi. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 1 mm. Typ. light spot size (distance): 3 mm x 6 mm (300 mm). Resolution: 0.2 mm. Measuring range: 100 mm ... 300 …

  • SICK DT20-P244BS04 (1052829)
    Product details Add to RFQ Add to RFQ

    DT20-P244BS04

    The DT20 Hi laser distance sensor, model DT20-P244BS04, provides precise distance measurement within a range of 100 to 300 mm. It features a digital PNP output and a current analog …

  • SICK DT20-P254B (1041278)
    Product details Add to RFQ Add to RFQ

    DT20-P254B

    The DT20 Hi series laser distance sensor, model DT20-P254B, provides precise distance measurement within a range of 50 to 150 mm. It features a digital output (1 x PNP) and a curre …

  • SICK DT2-410 (1024093)
    Product details Add to RFQ Add to RFQ

    DT2-410

    This industrial automation product provides advanced control capabilities for complex manufacturing processes. It integrates seamlessly with existing machinery, ensuring high level …

  • SICK DT80-311111 (1118113)
    Product details Add to RFQ Add to RFQ

    DT80-311111

    The Dx80 laser distance sensor (DT80-311111) features an IO-Link communication interface and offers a measuring range from 50 mm up to 80,000 mm. It supports various remission fact …

  • SICK OD1000-6001R15 (1075638)
    Product details Add to RFQ Add to RFQ

    OD1000-6001R15

    The OD1000 laser distance sensor is designed for industrial applications, featuring an IO-Link communication interface and dual digital outputs (2 x push-pull: PNP/NPN). It offers  …

  • SICK OD100-40N152 (6025045)
    Product details Add to RFQ Add to RFQ

    OD100-40N152

    OD Hi. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 800 µm. Typ. light spot size (distance): 1 mm x 1.5 mm (100 mm). Resolution: 35 µm. Measuring range: 60 mm ... 140 …

  • SICK OD100-40N850 (6025046)
    Product details Add to RFQ Add to RFQ

    OD100-40N850

    OD Hi. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 800 µm. Typ. light spot size (distance): 1 mm x 1.5 mm (100 mm). Resolution: 35 µm. Measuring range: 60 mm ... 140 …

  • SICK OD100-40P152 (6025043)
    Product details Add to RFQ Add to RFQ

    OD100-40P152

    OD Hi. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 800 µm. Typ. light spot size (distance): 1 mm x 1.5 mm (100 mm). Resolution: 35 µm. Measuring range: 60 mm ... 140 …

  • SICK OD100-40P850 (6025044)
    Product details Add to RFQ Add to RFQ

    OD100-40P850

    OD Hi. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 800 µm. Typ. light spot size (distance): 1 mm x 1.5 mm (100 mm). Resolution: 35 µm. Measuring range: 60 mm ... 140 …

  • SICK OD1-B015C05I14 (6050519)
    Product details Add to RFQ Add to RFQ

    OD1-B015C05I14

    OD Mini, 1 x 4 mA ... 20 mA (< 300 Ω), OD Mini Prime. Data interface: 1 x 4 mA ... 20 mA (< 300 Ω). Linearity: ± 10 µm. Typ. light spot size (distance): 700 µm x 500 µm (15 mm). Re …

  • SICK OD1-B015C05I25 (6050520)
    Product details Add to RFQ Add to RFQ

    OD1-B015C05I25

    OD Mini, 1 x 4 mA ... 20 mA (< 300 Ω), OD Mini Prime. Data interface: 1 x 4 mA ... 20 mA (< 300 Ω). Linearity: ± 10 µm. Typ. light spot size (distance): 700 µm x 500 µm (15 mm). Re …

  • SICK OD1-B015H05I14 (6050495)
    Product details Add to RFQ Add to RFQ

    OD1-B015H05I14

    OD Mini, 1 x 4 mA ... 20 mA (< 300 Ω), OD Mini Prime. Data interface: 1 x 4 mA ... 20 mA (< 300 Ω). Linearity: ± 10 µm. Typ. light spot size (distance): 700 µm x 500 µm (15 mm). Re …

  • SICK OD1-B015H05I25 (6050496)
    Product details Add to RFQ Add to RFQ

    OD1-B015H05I25

    OD Mini, 1 x 4 mA ... 20 mA (< 300 Ω), OD Mini Prime. Data interface: 1 x 4 mA ... 20 mA (< 300 Ω). Linearity: ± 10 µm. Typ. light spot size (distance): 700 µm x 500 µm (15 mm). Re …

  • SICK OD1-B015H05U14 (6050497)
    Product details Add to RFQ Add to RFQ

    OD1-B015H05U14

    OD Mini, 1 x 0 V ... 10 V (> 10 kΩ), OD Mini Prime. Data interface: 1 x 0 V ... 10 V (> 10 kΩ). Linearity: ± 10 µm. Typ. light spot size (distance): 700 µm x 500 µm (15 mm). Resolu …

  • SICK OD1-B015H05U25 (6050498)
    Product details Add to RFQ Add to RFQ

    OD1-B015H05U25

    OD Mini, 1 x 0 V ... 10 V (> 10 kΩ), OD Mini Prime. Data interface: 1 x 0 V ... 10 V (> 10 kΩ). Linearity: ± 10 µm. Typ. light spot size (distance): 700 µm x 500 µm (15 mm). Resolu …

  • SICK OD1-B035C15I14 (6050523)
    Product details Add to RFQ Add to RFQ

    OD1-B035C15I14

    OD Mini, 1 x 4 mA ... 20 mA (< 300 Ω), OD Mini Prime. Data interface: 1 x 4 mA ... 20 mA (< 300 Ω). Linearity: ± 30 µm. Typ. light spot size (distance): 800 µm x 450 µm (35 mm). Re …

  • SICK OD1-B035C15I25 (6050524)
    Product details Add to RFQ Add to RFQ

    OD1-B035C15I25

    OD Mini, 1 x 4 mA ... 20 mA (< 300 Ω), OD Mini Prime. Data interface: 1 x 4 mA ... 20 mA (< 300 Ω). Linearity: ± 30 µm. Typ. light spot size (distance): 800 µm x 450 µm (35 mm). Re …

  • SICK OD1-B035H15I14 (6050503)
    Product details Add to RFQ Add to RFQ

    OD1-B035H15I14

    OD Mini, 1 x 4 mA ... 20 mA (< 300 Ω), OD Mini Prime. Data interface: 1 x 4 mA ... 20 mA (< 300 Ω). Linearity: ± 30 µm. Typ. light spot size (distance): 800 µm x 450 µm (35 mm). Re …

  • SICK OD1-B035H15I25 (6050504)
    Product details Add to RFQ Add to RFQ

    OD1-B035H15I25

    OD Mini, 1 x 4 mA ... 20 mA (< 300 Ω), OD Mini Prime. Data interface: 1 x 4 mA ... 20 mA (< 300 Ω). Linearity: ± 30 µm. Typ. light spot size (distance): 800 µm x 450 µm (35 mm). Re …

  • SICK OD1-B035H15U14 (6050505)
    Product details Add to RFQ Add to RFQ

    OD1-B035H15U14

    OD Mini, 1 x 0 V ... 10 V (> 10 kΩ), OD Mini Prime. Data interface: 1 x 0 V ... 10 V (> 10 kΩ). Linearity: ± 30 µm. Typ. light spot size (distance): 800 µm x 450 µm (35 mm). Resolu …

  • SICK OD1-B035H15U25 (6050506)
    Product details Add to RFQ Add to RFQ

    OD1-B035H15U25

    The OD Mini OD1-B035H15U25 is a laser distance sensor designed for precise, short-range measurements. It features selectable PNP/NPN digital output and voltage analog output. The s …

  • SICK OD1-B100C50I14 (6050527)
    Product details Add to RFQ Add to RFQ

    OD1-B100C50I14

    OD Mini, 1 x 4 mA ... 20 mA (< 300 Ω), OD Mini Prime. Data interface: 1 x 4 mA ... 20 mA (< 300 Ω). Linearity: ± 100 µm. Typ. light spot size (distance): 700 µm x 600 µm (100 mm).  …

  • SICK OD1-B100C50I25 (6050528)
    Product details Add to RFQ Add to RFQ

    OD1-B100C50I25

    OD Mini, 1 x 4 mA ... 20 mA (< 300 Ω), OD Mini Prime. Data interface: 1 x 4 mA ... 20 mA (< 300 Ω). Linearity: ± 100 µm. Typ. light spot size (distance): 700 µm x 600 µm (100 mm).  …

  • SICK OD1-B100H50I14 (6050511)
    Product details Add to RFQ Add to RFQ

    OD1-B100H50I14

    OD Mini, 1 x 4 mA ... 20 mA (< 300 Ω), OD Mini Prime. Data interface: 1 x 4 mA ... 20 mA (< 300 Ω). Linearity: ± 100 µm. Typ. light spot size (distance): 700 µm x 600 µm (100 mm).  …

  • SICK OD1-B100H50I25 (6050512)
    Product details Add to RFQ Add to RFQ

    OD1-B100H50I25

    OD Mini, 1 x 4 mA ... 20 mA (< 300 Ω), OD Mini Prime. Data interface: 1 x 4 mA ... 20 mA (< 300 Ω). Linearity: ± 100 µm. Typ. light spot size (distance): 700 µm x 600 µm (100 mm).  …

  • SICK OD1-B100H50U14 (6050513)
    Product details Add to RFQ Add to RFQ

    OD1-B100H50U14

    OD Mini, 1 x 0 V ... 10 V (> 10 kΩ), OD Mini Prime. Data interface: 1 x 0 V ... 10 V (> 10 kΩ). Linearity: ± 100 µm. Typ. light spot size (distance): 700 µm x 600 µm (100 mm). Reso …

  • SICK OD1-B100H50U25 (6050514)
    Product details Add to RFQ Add to RFQ

    OD1-B100H50U25

    OD Mini, 1 x 0 V ... 10 V (> 10 kΩ), OD Mini Prime. Data interface: 1 x 0 V ... 10 V (> 10 kΩ). Linearity: ± 100 µm. Typ. light spot size (distance): 700 µm x 600 µm (100 mm). Reso …

  • SICK OD2000-0301T15 (6074380)
    Product details Add to RFQ Add to RFQ

    OD2000-0301T15

    The OD2000 laser distance sensor, model OD2000-0301T15, provides precise distance measurement with a range of 25mm to 35mm and linearity of ±10µm. It features an IO-Link communicat …

  • SICK OD2000-2452T15 (6074383)
    Product details Add to RFQ Add to RFQ

    OD2000-2452T15

    The OD2000 laser distance sensor is a high-precision industrial component featuring an IO-Link communication interface and selectable digital outputs (2 x PNP/NPN). It offers versa …

  • SICK OD250-150N152 (6028095)
    Product details Add to RFQ Add to RFQ

    OD250-150N152

    OD Hi. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 6 mm. Typ. light spot size (distance): 1.5 mm x 3 mm (250 mm). Resolution: 75 µm. Measuring range: 100 mm ... 400  …

  • SICK OD250-150N850 (6028097)
    Product details Add to RFQ Add to RFQ

    OD250-150N850

    OD Hi. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 6 mm. Typ. light spot size (distance): 1.5 mm x 3 mm (250 mm). Resolution: 75 µm. Measuring range: 100 mm ... 400  …

  • SICK OD250-150P152 (6028094)
    Product details Add to RFQ Add to RFQ

    OD250-150P152

    OD Hi. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 6 mm. Typ. light spot size (distance): 1.5 mm x 3 mm (250 mm). Resolution: 75 µm. Measuring range: 100 mm ... 400  …

  • SICK OD250-150P850 (6028096)
    Product details Add to RFQ Add to RFQ

    OD250-150P850

    OD Hi. Data interface: 1 x 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 6 mm. Typ. light spot size (distance): 1.5 mm x 3 mm (250 mm). Resolution: 75 µm. Measuring range: 100 mm ... 400  …

  • SICK OD-25-01T1 (6030977)
    Product details Add to RFQ Add to RFQ

    OD-25-01T1

    OD Max. Linearity: ± 2 µm. Typ. light spot size (distance): 25 µm x 35 µm (25 mm). Resolution: 0.1 µm. Measuring range: 24 mm ... 26 mm, 6 % ... 90 % remission. Connection type: 0. …

  • SICK OD2-N120W60A0 (6036624)
    Product details Add to RFQ Add to RFQ

    OD2-N120W60A0

    OD Value, RS-422. Data interface: RS-422. Linearity: ± 120 µm. Typ. light spot size (distance): 1 mm x 1.5 mm (120 mm). Resolution: 30 µm. Measuring range: 60 mm ... 180 mm, 6 % .. …

  • SICK OD2-N120W60A2 (6036620)
    Product details Add to RFQ Add to RFQ

    OD2-N120W60A2

    OD Value, RS-422. Data interface: RS-422. Linearity: ± 120 µm. Typ. light spot size (distance): 1 mm x 1.5 mm (120 mm). Resolution: 30 µm. Measuring range: 60 mm ... 180 mm, 6 % .. …

  • SICK OD2-N120W60C0 (6036623)
    Product details Add to RFQ Add to RFQ

    OD2-N120W60C0

    OD Value. Linearity: ± 120 µm. Typ. light spot size (distance): 1 mm x 1.5 mm (120 mm). Resolution: 30 µm. Measuring range: 60 mm ... 180 mm, 6 % ... 90 % remission. Connection typ …

  • SICK OD2-N120W60C2 (6036619)
    Product details Add to RFQ Add to RFQ

    OD2-N120W60C2

    OD Value. Linearity: ± 120 µm. Typ. light spot size (distance): 1 mm x 1.5 mm (120 mm). Resolution: 30 µm. Measuring range: 60 mm ... 180 mm, 6 % ... 90 % remission. Connection typ …

  • SICK OD2-N120W60I0 (6036621)
    Product details Add to RFQ Add to RFQ

    OD2-N120W60I0

    OD Value, 4 mA ... 20 mA (≤ 300 Ω). Data interface: 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 120 µm. Typ. light spot size (distance): 1 mm x 1.5 mm (120 mm). Resolution: 30 µm. Measu …

  • SICK OD2-N120W60I2 (6036617)
    Product details Add to RFQ Add to RFQ

    OD2-N120W60I2

    OD Value, 4 mA ... 20 mA (≤ 300 Ω). Data interface: 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 120 µm. Typ. light spot size (distance): 1 mm x 1.5 mm (120 mm). Resolution: 30 µm. Measu …

  • SICK OD2-N120W60U0 (6036622)
    Product details Add to RFQ Add to RFQ

    OD2-N120W60U0

    OD Value, 0 V ... 10 V (≥ 10 kΩ). Data interface: 0 V ... 10 V (≥ 10 kΩ). Linearity: ± 120 µm. Typ. light spot size (distance): 1 mm x 1.5 mm (120 mm). Resolution: 30 µm. Measuring …

  • SICK OD2-N120W60U2 (6036618)
    Product details Add to RFQ Add to RFQ

    OD2-N120W60U2

    OD Value, 0 V ... 10 V (≥ 10 kΩ). Data interface: 0 V ... 10 V (≥ 10 kΩ). Linearity: ± 120 µm. Typ. light spot size (distance): 1 mm x 1.5 mm (120 mm). Resolution: 30 µm. Measuring …

  • SICK OD2-N250W150A0 (6036640)
    Product details Add to RFQ Add to RFQ

    OD2-N250W150A0

    OD Value, RS-422. Data interface: RS-422. Linearity: ± 750 µm. Typ. light spot size (distance): 1.8 mm x 3.5 mm (250 mm). Resolution: 75 µm. Measuring range: 100 mm ... 400 mm, 6 % …

  • SICK OD2-N250W150A2 (6036636)
    Product details Add to RFQ Add to RFQ

    OD2-N250W150A2

    OD Value, RS-422. Data interface: RS-422. Linearity: ± 750 µm. Typ. light spot size (distance): 1.8 mm x 3.5 mm (250 mm). Resolution: 75 µm. Measuring range: 100 mm ... 400 mm, 6 % …

  • SICK OD2-N250W150C0 (6036639)
    Product details Add to RFQ Add to RFQ

    OD2-N250W150C0

    OD Value. Linearity: ± 750 µm. Typ. light spot size (distance): 1.8 mm x 3.5 mm (250 mm). Resolution: 75 µm. Measuring range: 100 mm ... 400 mm, 6 % ... 90 % remission. Connection  …

  • SICK OD2-N250W150C2 (6036635)
    Product details Add to RFQ Add to RFQ

    OD2-N250W150C2

    OD Value. Linearity: ± 750 µm. Typ. light spot size (distance): 1.8 mm x 3.5 mm (250 mm). Resolution: 75 µm. Measuring range: 100 mm ... 400 mm, 6 % ... 90 % remission. Connection  …

  • SICK OD2-N250W150I0 (6036637)
    Product details Add to RFQ Add to RFQ

    OD2-N250W150I0

    OD Value, 4 mA ... 20 mA (≤ 300 Ω). Data interface: 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 750 µm. Typ. light spot size (distance): 1.8 mm x 3.5 mm (250 mm). Resolution: 75 µm. Mea …

  • SICK OD2-N250W150I2 (6036633)
    Product details Add to RFQ Add to RFQ

    OD2-N250W150I2

    OD Value, 4 mA ... 20 mA (≤ 300 Ω). Data interface: 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 750 µm. Typ. light spot size (distance): 1.8 mm x 3.5 mm (250 mm). Resolution: 75 µm. Mea …

  • SICK OD2-N250W150U0 (6036638)
    Product details Add to RFQ Add to RFQ

    OD2-N250W150U0

    OD Value, 0 V ... 10 V (≥ 10 kΩ). Data interface: 0 V ... 10 V (≥ 10 kΩ). Linearity: ± 750 µm. Typ. light spot size (distance): 1.8 mm x 3.5 mm (250 mm). Resolution: 75 µm. Measuri …

  • SICK OD2-N250W150U2 (6036634)
    Product details Add to RFQ Add to RFQ

    OD2-N250W150U2

    OD Value, 0 V ... 10 V (≥ 10 kΩ). Data interface: 0 V ... 10 V (≥ 10 kΩ). Linearity: ± 750 µm. Typ. light spot size (distance): 1.8 mm x 3.5 mm (250 mm). Resolution: 75 µm. Measuri …

  • SICK OD2-N30W04A0 (6036575)
    Product details Add to RFQ Add to RFQ

    OD2-N30W04A0

    OD Value, RS-422. Data interface: RS-422. Linearity: ± 8 µm. Typ. light spot size (distance): 0.1 mm x 0.1 mm (30 mm). Resolution: 2 µm. Measuring range: 26 mm ... 34 mm, 6 % ... 9 …

  • SICK OD2-N30W04A2 (6036571)
    Product details Add to RFQ Add to RFQ

    OD2-N30W04A2

    OD Value, RS-422. Data interface: RS-422. Linearity: ± 8 µm. Typ. light spot size (distance): 0.1 mm x 0.1 mm (30 mm). Resolution: 2 µm. Measuring range: 26 mm ... 34 mm, 6 % ... 9 …

  • SICK OD2-N30W04C0 (6036574)
    Product details Add to RFQ Add to RFQ

    OD2-N30W04C0

    OD Value. Linearity: ± 8 µm. Typ. light spot size (distance): 0.1 mm x 0.1 mm (30 mm). Resolution: 2 µm. Measuring range: 26 mm ... 34 mm, 6 % ... 90 % remission. Connection type:  …

  • SICK OD2-N30W04C2 (6036570)
    Product details Add to RFQ Add to RFQ

    OD2-N30W04C2

    OD Value. Linearity: ± 8 µm. Typ. light spot size (distance): 0.1 mm x 0.1 mm (30 mm). Resolution: 2 µm. Measuring range: 26 mm ... 34 mm, 6 % ... 90 % remission. Connection type:  …

  • SICK OD2-N30W04I0 (6036572)
    Product details Add to RFQ Add to RFQ

    OD2-N30W04I0

    OD Value, 4 mA ... 20 mA (≤ 300 Ω). Data interface: 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 8 µm. Typ. light spot size (distance): 0.1 mm x 0.1 mm (30 mm). Resolution: 2 µm. Measuri …

  • SICK OD2-N30W04I2 (6036568)
    Product details Add to RFQ Add to RFQ

    OD2-N30W04I2

    OD Value, 4 mA ... 20 mA (≤ 300 Ω). Data interface: 4 mA ... 20 mA (≤ 300 Ω). Linearity: ± 8 µm. Typ. light spot size (distance): 0.1 mm x 0.1 mm (30 mm). Resolution: 2 µm. Measuri …

  • SICK OD2-N30W04U0 (6036573)
    Product details Add to RFQ Add to RFQ

    OD2-N30W04U0

    OD Value, 0 V ... 10 V (≥ 10 kΩ). Data interface: 0 V ... 10 V (≥ 10 kΩ). Linearity: ± 8 µm. Typ. light spot size (distance): 0.1 mm x 0.1 mm (30 mm). Resolution: 2 µm. Measuring r …

  • SICK OD2-N30W04U2 (6036569)
    Product details Add to RFQ Add to RFQ

    OD2-N30W04U2

    OD Value, 0 V ... 10 V (≥ 10 kΩ). Data interface: 0 V ... 10 V (≥ 10 kΩ). Linearity: ± 8 µm. Typ. light spot size (distance): 0.1 mm x 0.1 mm (30 mm). Resolution: 2 µm. Measuring r …

  • SICK OD2-N50W10A0 (6036591)
    Product details Add to RFQ Add to RFQ

    OD2-N50W10A0

    OD Value, RS-422. Data interface: RS-422. Linearity: ± 20 µm. Typ. light spot size (distance): 0.5 mm x 1 mm (50 mm). Resolution: 5 µm. Measuring range: 40 mm ... 60 mm, 6 % ... 90 …

  • SICK OD2-N50W10A2 (6036587)
    Product details Add to RFQ Add to RFQ

    OD2-N50W10A2

    OD Value, RS-422. Data interface: RS-422. Linearity: ± 20 µm. Typ. light spot size (distance): 0.5 mm x 1 mm (50 mm). Resolution: 5 µm. Measuring range: 40 mm ... 60 mm, 6 % ... 90 …

« Prev page Next page »

SICK ⍾ Recently updated

YF2L15-020UH1XLEAX YF2A15-200UB5M2A15 YF2A15-150UB5M2A15 YF2A15-050UB5M2A15 YF2A15-020UB5XLEAX YF2A14-050UB3XLEAX YF2A14-010UB3M2A14 STE-1204-G BEF-AP-W280 FBM-H11
  • Home
  • About us
  • Privacy policy
  • Select brand
    ABB BANNER Baumer BECKHOFF Danfoss ifm INNOMOTICS Keyence Murrelektronik OBO Omron Pepperl+Fuchs Phoenix Contact PILZ Schneider Electric SICK SIEMENS Telemecanique Turck Weidmüller WEINTEK Yaskawa
  • Contacts
  • English en English
    English Deutsch Español Polski
  • Add to RFQ RFQ

© INT TECHNICS Sp. z o.o.

Żadna z przedstawionych w serwisie stron nie jest ofertą w rozumieniu Kodeksu Cywilnego. Jeśli w opisie prezentowanego produktu występuje cena, ma ona wyłącznie charakter orientacyjny. Loga i nazwy firm są własnością ich prawnych właścicieli i zostały użyte tylko w celach informacyjnych.

Spam kieruj na oumuamua@int-technics.pl