SU7001 ifm ⍾ SUR34HGBFRKG/W/US-100-IPF
Ultrasonic flow meter; Operating voltage [V] : 19...30 DC; (according to EN 50178 SELV/PELV); Min. insulation resistance [MΩ] : 100; (500 V DC); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 10; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max. voltage drop switching output DC [V] : 2; Permanent current rating of switching output DC [mA] : 250; (per output); Number of analogue outputs : 1; Analogue current output [mA] : 4...20; (scalable); Max. load [Ω] : 500; Analogue voltage output [V] : 0...10; (scalable); Min. load resistance [Ω] : 2000; Pulse output : flow rate meter; Short-circuit protection : yes; Type of short-circuit protection : pulsed; Overload protection : yes; Measuring range : 0...792.5 gph: 0...13.21 gpm; Display range : 0...951 gph: 0...15.86 gpm; Resolution : 1 gph: 0.02 gpm; Set point SP : 1...793 gph: 0.02...13.22 gpm; Reset point rP : 0...791 gph: 0...13.2 gpm; Analogue start point ASP : 0...637 gph: 0...10.62 gpm; Analogue end point AEP : 156...793 gph: 2.6...13.22 gpm; Max. flow rate : 951 gph: 15.86 gpm; In steps of : 1 gph: 0.02 gpm; Pulse value : 0.02...9000 * 10³ gal; In steps of : 0.02 gal; Pulse length [s] : 0,6...2; Dynamic response T05 / T09 [s] : T09 = 70 (Q > 1 gpm); (water); Response time [s] : 0.25; (dAP = 0); Delay time programmable dS, dr [s] : 0...50; Damping for the switching output dAP [s] : 0...1; Parameter setting options : Flow monitoring; quantity meter; Preset counter; Temperature monitoring; Ambient temperature [°F] : 14...140; Storage temperature [°F] : -13...176; Materials : housing: AlMgSi0,5 anodised; Sealing: FKM; PA 6.6; cover film: PA; Materials (wetted parts) : stainless steel (1.4404 / 316L); FKM; PES; Centellen 200; Process connection : threaded connection G 3/4 flat seal; Items supplied : sealings: 2, Centellen; Accessories (optional) : adapter for pipe: 1 x 1/2" NPT, stainless steel, E40191 | adapter for pipe: 1 x 1/2" NPT, brass, E40154
- Type
- Flow sensors / flow meters
- Connection
- Connector: 1 x M12; Moulded body: brass, Optalloy-plated; Contacts: gold-plated
- No. of inputs/outputs
- Number of digital outputs: 2; Number of analogue outputs: 1
- Current consumption
- 100 mA
- Voltage supply
- 24 V
- Display
- Display unit: 5 x LED, green (gpm, gph, gal, °F, 10³) | switching status: 2 x LED, yellow | measured values: alphanumeric display, 4-digit | programming: alphanumeric display, 4-digit
- Degree of protection
- IP 67
- Weight
- 1505.5 g
- Dimensions
- 104.5 x 32.5 x 113.6 mm