Process sensors Items 1 - 96 of 1279 ⍾ ifm ⍾ Last modified
Process sensors ⍾ Page 1
-
-
-
-
-
-
-
-
-
-
-
E35210
Welding thermowell for temperature sensors; Probe length L [mm] : 73; Materials : stainless steel (1.4571/316Ti ); Sensor connection : G 1/2; Process connection : welding adapter Ø …
-
E35220
Welding thermowell for temperature sensors; Probe length L [mm] : 173; Materials : stainless steel (1.4571/316Ti ); Sensor connection : G 1/2; Process connection : welding adapter …
-
-
E37210
Thermowell for temperature sensors; Max. permissible flow velocity [m/s] : 45; Materials : stainless steel (1.4404 / 316L); Sensor connection : 1/2" NPS Ø 6 mm suitable for G1/2 an …
-
E37211
Thermowell for temperature sensors; Materials : stainless steel (1.4404 / 316L); Sensor connection : G 1/2 sealing cone Ø 6 mm; Process connection : 1/2" NPT; Installation length E …
-
E37220
Thermowell for temperature sensors; Max. permissible flow velocity [m/s] : 25; Materials : stainless steel (1.4404 / 316L); Sensor connection : 1/2" NPS Ø 6 mm suitable for G1/2 an …
-
E37221
Thermowell for temperature sensors; Materials : stainless steel (1.4404 / 316L); Sensor connection : G 1/2 sealing cone Ø 6 mm; Process connection : 1/2" NPT; Installation length E …
-
E37230
Thermowell for temperature sensors; Max. permissible flow velocity [m/s] : 12; Materials : stainless steel (1.4404 / 316L); Sensor connection : 1/2" NPS Ø 6 mm suitable for G1/2 an …
-
E37250
Thermowell for temperature sensors; Max. permissible flow velocity [m/s] : 6; Materials : stainless steel (1.4404 / 316L); Sensor connection : 1/2" NPS Ø 6 mm suitable for G1/2 and …
-
E37411
Welding thermowell for temperature sensors; Materials : stainless steel (1.4404 / 316L); Sensor connection : G 1/2 sealing cone Ø 6 mm; Process connection : welding adapter Ø 34 mm …
-
E37421
Welding thermowell for temperature sensors; Materials : stainless steel (1.4404 / 316L); Sensor connection : G 1/2 sealing cone Ø 6 mm; Process connection : welding adapter Ø 34 mm …
-
E37430
Welding thermowell for temperature sensors; Max. permissible flow velocity [m/s] : 25; Materials : stainless steel (1.4404 / 316L); Sensor connection : 1/2" NPS Ø 6 mm suitable for …
-
E37431
Welding thermowell for temperature sensors; Materials : stainless steel (1.4404 / 316L); Sensor connection : G 1/2 sealing cone Ø 6 mm; Process connection : welding adapter Ø 34 mm …
-
E37450
Welding thermowell for temperature sensors; Max. permissible flow velocity [m/s] : 13; Materials : stainless steel (1.4404 / 316L); Sensor connection : 1/2" NPS Ø 6 mm suitable for …
-
E37511
Thermowell for temperature sensors; Materials : stainless steel (1.4404 / 316L); Sensor connection : G 1/2 sealing cone Ø 6 mm; Process connection : G 1/2; Surface characteristics …
-
E37521
Thermowell for temperature sensors; Materials : stainless steel (1.4404 / 316L); Sensor connection : G 1/2 sealing cone Ø 6 mm; Process connection : G 1/2; Surface characteristics …
-
E37600
Thermowell for temperature sensors; Materials : stainless steel (1.4571/316Ti ); Sensor connection : G 1/2 Ø 6 mm; Process connection : G 1/2; Installation length EL [mm] : 27; Bor …
-
E37603
Thermowell for temperature sensors; Materials : stainless steel (1.4571/316Ti ); Sensor connection : Ø 6 mm; Process connection : G 1/2; Installation length EL [mm] : 33; Bore leng …
-
E37610
Thermowell for temperature sensors; Materials : stainless steel (1.4571/316Ti ); Sensor connection : G 1/2 Ø 6 mm; Process connection : G 1/2; Installation length EL [mm] : 74; Bor …
-
E37613
Thermowell for temperature sensors; Materials : stainless steel (1.4571/316Ti ); Sensor connection : Ø 6 mm; Process connection : G 1/2; Installation length EL [mm] : 83; Bore leng …
-
E37620
Thermowell for temperature sensors; Materials : stainless steel (1.4571/316Ti ); Sensor connection : G 1/2 Ø 6 mm; Process connection : G 1/2; Installation length EL [mm] : 124; Bo …
-
E37623
Thermowell for temperature sensors; Materials : stainless steel (1.4571/316Ti ); Sensor connection : Ø 6 mm; Process connection : G 1/2; Installation length EL [mm] : 128; Bore len …
-
E37640
Thermowell for temperature sensors; Materials : stainless steel (1.4571/316Ti ); Sensor connection : G 1/2 Ø 6 mm; Process connection : G 1/2; Installation length EL [mm] : 224; Bo …
-
E37643
Thermowell for temperature sensors; Materials : stainless steel (1.4571/316Ti ); Sensor connection : Ø 6 mm; Process connection : G 1/2; Installation length EL [mm] : 233; Bore len …
-
E37663
Thermowell for temperature sensors; Materials : stainless steel (1.4571/316Ti ); Sensor connection : Ø 6 mm; Process connection : G 1/2; Installation length EL [mm] : 333; Bore len …
-
E37810
Thermowell for temperature sensors; Materials : stainless steel (1.4404 / 316L); Sensor connection : 1/2" NPS Ø 6 mm suitable for G1/2 and 1/2" NPT; Process connection : Clamp DN25 …
-
E37820
Thermowell for temperature sensors; Materials : stainless steel (1.4404 / 316L); Sensor connection : 1/2" NPS Ø 6 mm suitable for G1/2 and 1/2" NPT; Process connection : Clamp DN25 …
-
E37830
Thermowell for temperature sensors; Materials : stainless steel (1.4404 / 316L); Sensor connection : 1/2" NPS Ø 6 mm suitable for G1/2 and 1/2" NPT; Process connection : Clamp DN25 …
-
E37850
Thermowell for temperature sensors; Materials : stainless steel (1.4404 / 316L); Sensor connection : 1/2" NPS Ø 6 mm suitable for G1/2 and 1/2" NPT; Process connection : Clamp DN25 …
-
E37910
Thermowell for temperature sensors; Materials : stainless steel (1.4404 / 316L); Sensor connection : 1/2" NPS Ø 6 mm suitable for G1/2 and 1/2" NPT; Process connection : Clamp DN50 …
-
E37920
Thermowell for temperature sensors; Materials : stainless steel (1.4404 / 316L); Sensor connection : 1/2" NPS Ø 6 mm suitable for G1/2 and 1/2" NPT; Process connection : Clamp DN50 …
-
E37930
Thermowell for temperature sensors; Materials : stainless steel (1.4404 / 316L); Sensor connection : 1/2" NPS Ø 6 mm suitable for G1/2 and 1/2" NPT; Process connection : Clamp DN50 …
-
E37950
Thermowell for temperature sensors; Materials : stainless steel (1.4404 / 316L); Sensor connection : 1/2" NPS Ø 6 mm suitable for G1/2 and 1/2" NPT; Process connection : Clamp DN50 …
-
IN5416
Inductive dual sensor for valve actuators; Operating voltage [V] : 10...36 DC; Rated insulation voltage [V] : 250; Protection class : II; Reverse polarity protection : yes; Electri …
-
-
LI2141
Level sensor for limit detection with overspill protection (German Federal Water Act); Medium temperature [°C] : 0...65; Medium temperature [°C] : 0...35; Operating voltage [V] : 1 …
-
LI2142
Level sensor for limit detection with overspill protection (German Federal Water Act); Medium temperature [°C] : 0...65; Medium temperature [°C] : 0...35; Operating voltage [V] : 1 …
-
LI2143
Level sensor for limit detection with overspill protection (German Federal Water Act); Medium temperature [°C] : 0...65; Medium temperature [°C] : 0...35; Operating voltage [V] : 1 …
-
LI2241
Level sensor / leakage sensor (German Federal Water Act); Medium temperature [°C] : 0...65; Medium temperature [°C] : 0...35; Operating voltage [V] : 10...36 DC; (operating voltag …
-
LI2242
Level sensor / leakage sensor (German Federal Water Act); Medium temperature [°C] : 0...65; Medium temperature [°C] : 0...35; Operating voltage [V] : 10...36 DC; (operating voltag …
-
LI2243
Level sensor / leakage sensor (German Federal Water Act); Medium temperature [°C] : 0...65; Medium temperature [°C] : 0...35; Operating voltage [V] : 10...36 DC; (operating voltag …
-
-
-
-
-
-
-
-
LK1022
Electronic level sensor; Medium temperature [°C] : 0...35; (with climatic tube E43100: 35...65 °C); Medium temperature [°C] : 0...70; Medium temperature short time [°C] : 0...90; …
-
LK1023
Electronic level sensor; Medium temperature [°C] : 0...35; (with climatic tube E43101: 35...60 °C); Medium temperature [°C] : 0...70; Medium temperature short time [°C] : 0...90; …
-
LK1024
Electronic level sensor; Medium temperature [°C] : 0...35; (with climatic tube E43102: 35...55 °C); Medium temperature [°C] : 0...70; Medium temperature short time [°C] : 0...90; …
-
LK1222
Continuous level sensor with overspill monitoring; Medium temperature [°C] : 0...35; (with climatic tube E43100: 35...65 °C; not for applications to WHG (German Federal Water Act) …
-
LK1223
Continuous level sensor with overspill monitoring; Medium temperature [°C] : 0...35; (with climatic tube E43101: 35...60 °C; not for applications to WHG (German Federal Water Act) …
-
LK1224
Continuous level sensor with overspill monitoring; Medium temperature [°C] : 0...35; (with climatic tube E43102: 35...55 °C; not for applications to WHG (German Federal Water Act) …
-
LK3122
Electronic level sensor; Medium temperature [°C] : 0...35; (with climatic tube E43100: 35...65 °C); Medium temperature [°C] : 0...70; Medium temperature short time [°C] : 0...90; …
-
LK3123
Electronic level sensor; Medium temperature [°C] : 0...35; (with climatic tube E43101: 35...60 °C); Medium temperature [°C] : 0...70; Medium temperature short time [°C] : 0...90; …
-
LK3124
Electronic level sensor; Medium temperature [°C] : 0...35; (with climatic tube E43102: 35...55 °C); Medium temperature [°C] : 0...70; Medium temperature short time [°C] : 0...90; …
-
LK7022
Electronic level sensor; Medium temperature [°C] : 0...35; (with climatic tube E43100: 35...65 °C); Medium temperature [°C] : 0...70; Medium temperature short time [°C] : 0...90; …
-
LK7023
Electronic level sensor; Medium temperature [°C] : 0...35; (with climatic tube E43101: 35...60 °C); Medium temperature [°C] : 0...70; Medium temperature short time [°C] : 0...90; …
-
LK7024
Electronic level sensor; Medium temperature [°C] : 0...35; (with climatic tube E43102); Medium temperature [°C] : 0...70; Medium temperature short time [°C] : 0...90; (< 1 h); Me …
-
LK8122
Electronic level sensor; Medium temperature [°C] : 0...35; (with climatic tube E43100: 35...65 °C); Medium temperature [°C] : 0...70; Medium temperature short time [°C] : 0...90; …
-
LK8123
Electronic level sensor; Medium temperature [°C] : 0...35; (with climatic tube E43101: 35...60 °C); Medium temperature [°C] : 0...70; Medium temperature short time [°C] : 0...90; …
-
LK8124
Electronic level sensor; Medium temperature [°C] : 0...35; (with climatic tube E43102: 35...55 °C); Medium temperature [°C] : 0...70; Medium temperature short time [°C] : 0...90; …
-
LMC100
Sensor for point level detection; Medium temperature [°C] : -25...100; Operating voltage [V] : 18...30 DC; Protection class : III; Reverse polarity protection : yes; Total number o …
-
LMC110
Sensor for point level detection; Medium temperature [°C] : -25...100; Operating voltage [V] : 18...30 DC; Protection class : III; Reverse polarity protection : yes; Total number o …
-
LMC400
Sensor for point level detection; Medium temperature [°C] : -25...100; Operating voltage [V] : 18...30 DC; Protection class : III; Reverse polarity protection : yes; Total number o …
-
LMC410
Sensor for point level detection; Medium temperature [°C] : -25...100; Operating voltage [V] : 18...30 DC; Protection class : III; Reverse polarity protection : yes; Total number o …
-
LMC500
Sensor for point level detection; Medium temperature [°C] : -25...100; Operating voltage [V] : 18...30 DC; Protection class : III; Reverse polarity protection : yes; Total number o …
-
LMC502
Sensor for point level detection; Medium temperature [°C] : -20...100; Medium temperature short time [°C] : -20...150; (1 h); Operating voltage [V] : 18...30 DC; Protection class …
-
LMC510
Sensor for point level detection; Medium temperature [°C] : -25...100; Operating voltage [V] : 18...30 DC; Protection class : III; Reverse polarity protection : yes; Total number o …
-
LMT01A
Sensor for point level detection in hazardous areas; Operating voltage [V] : 18...30 DC; Protection class : III; Reverse polarity protection : yes; Measuring principle : capacitive …
-
LMT03A
Sensor for point level detection in hazardous areas; Operating voltage [V] : 18...30 DC; Protection class : III; Reverse polarity protection : yes; Measuring principle : capacitive …
-
LMT04A
Sensor for point level detection in hazardous areas; Operating voltage [V] : 18...30 DC; Protection class : III; Reverse polarity protection : yes; Measuring principle : capacitive …
-
LMT100
Sensor for point level detection; Medium temperature [°C] : -40...100; Medium temperature short time [°C] : -40...150; (1 h); Operating voltage [V] : 18...30 DC; Protection class …
-
LMT102
Sensor for point level detection; Medium temperature [°C] : -20...100; Medium temperature short time [°C] : -20...150; (1 h); Operating voltage [V] : 18...30 DC; Protection class …
-
LMT104
Sensor for point level detection; Medium temperature [°C] : -20...100; Medium temperature short time [°C] : -20...150; (1 h); Operating voltage [V] : 18...30 DC; Protection class …
-
LMT105
Sensor for point level detection; Medium temperature [°C] : -20...100; Medium temperature short time [°C] : -20...150; (1 h); Operating voltage [V] : 18...30 DC; Protection class …
-
LMT110
Sensor for point level detection; Medium temperature [°C] : -40...100; Medium temperature short time [°C] : -40...150; (1 h); Operating voltage [V] : 18...30 DC; Protection class …
-
LMT121
Sensor for point level detection; Medium temperature [°C] : -40...100; Medium temperature short time [°C] : -40...150; (1 h); Operating voltage [V] : 18...30 DC; Protection class …
-
LMT191
Level sensor for limit detection with overspill protection (German Federal Water Act); Medium temperature [°C] : -40...100; (applications subject to the German Federal Water Act …
-
LMT192
Level sensor for limit detection with overspill protection (German Federal Water Act); Medium temperature [°C] : -25...100; (applications subject to the German Federal Water Act …
-
LMT194
Level sensor for limit detection with overspill protection (German Federal Water Act); Medium temperature [°C] : -25...100; (applications subject to the German Federal Water Act …
-
LMT195
Level sensor for limit detection with overspill protection (German Federal Water Act); Medium temperature [°C] : -25...100; (applications subject to the German Federal Water Act …
-
LMT202
Sensor for point level detection; Medium temperature [°C] : -20...100; Medium temperature short time [°C] : -20...150; (1 h); Operating voltage [V] : 18...30 DC; Protection class …
-
LMT292
Sensor for point level detection; Medium temperature [°C] : -25...100; (applications subject to the German Federal Water Act 0...100 °C); Medium temperature short time [°C] : -25 …
-
LMT302
Sensor for point level detection; Medium temperature [°C] : -20...100; Medium temperature short time [°C] : -20...150; (1 h); Operating voltage [V] : 18...30 DC; Protection class …