250-1BS00 Yaskawa ⍾ 2501BS00
250-1BS00 - Function modules | SSI modules; Order no. : 250-1BS00; Type : FM 250S; Features : 1 SSI channel RS42212/24 Bit Direct power supply to the SSI transducer Baud rate: 100/300/600 Kbit/s (default: 300 Kbit/s)2x parameterizable DO, DC 24 V, 1 A One may be used as hold input; Current consumption from backplane bus : 120 mA; Power loss : 1 W; Number of inputs : 1; Cable length, shielded : 1000 m; Cable length, unshielded : 600 m; Rated load voltage : DC 24 V; Reverse polarity protection of rated load voltage : Current consumption from load voltage L+ (without load) : 5 mA; Rated value : DC 20.4...28.8 V; Input voltage for signal "0" : DC 0...5 V; Input voltage for signal "1" : DC 15...28.8 V; Input current for signal "1" : 7 mA; Input delay of "0" to "1" : 3 ms; Input delay of "1" to "0" : 3 ms; Number of simultaneously utilizable inputs horizontal configuration : 1; Number of simultaneously utilizable inputs vertical configuration : 1; Input characteristic curve : IEC 61131-2, type 1; Initial data size : 4 Byte; Number of outputs : 2; Cable length, shielded : 1000 m; Cable length, unshielded : 600 m; Rated load voltage : DC 24 V; Reverse polarity protection of rated load voltage : Current consumption from load voltage L+ (without load) : 5 mA; Total current per group, horizontal configuration, 40°C : 2 A; Total current per group, horizontal configuration, 60°C : 2 A; Total current per group, vertical configuration : 2 A; Output voltage signal "1" at min. current : L+ (-0.8 V); Output voltage signal "1" at max. current : L+ (-125 mV); Output current at signal "1", rated value : 1 A; Output delay of "0" to "1" : max. 100 µs; Output delay of "1" to "0" : max. 350 µs; Lamp load : 5 W; Parallel switching of outputs for redundant control of a load : not possible; Parallel switching of outputs for increased power : not possible; Switching frequency with resistive load : max. 1000 Hz; Switching frequency with inductive load : max. 0.5 Hz; Switching frequency on lamp load : max. 10 Hz; Internal limitation of inductive shut-off voltage : L+ (-52 V); Short-circuit protection of output : yes, electronic; Trigger level : 1.8 A; Output data size : 4 Byte; Status display : yes; Interrupts : no; Process alarm : no; Diagnostic interrupt : no; Diagnostic functions : no; Diagnostics information read-out : none; Supply voltage display : yes; Group error display : yes; Channel error display : none; Between channels and backplane bus : Insulation tested with : DC 500 V; Interfaces type : RS422; Encoder frequency / baud rate : parameterizable (100k, 300kHz); SSI pause time : 35µs; Bit length encoder data : 24 Bit; Mode master : Shift direction MSB first : Binary code : Gray code : Input bytes : 4; Output bytes : 4; Parameter bytes : 6; Diagnostic bytes : 0; Material : PPE / PA 6.6; Mounting : Profile rail 35 mm; Dimensions (WxHxD) : 25.4 mm x 76 mm x 78 mm; Net weight : 100 g; Operating temperature : 0 °C to 60 °C; Storage temperature : -25 °C to 70 °C; UL certification : yes