250-1BA00 Yaskawa2501BA00

250-1BA00 - Function modules | Counter modules; Order no. : 250-1BA00; Type : FM 250; Features : 2/4 channels with 32/16 Bit Supply DC 24 V and above backplane bus 24 V outputs (1 A) free configurable Up to 1 MHz; Current consumption from backplane bus : 80 mA; Power loss : 2.5 W; Number of inputs : 6; Cable length, shielded : 1000 m; Cable length, unshielded : 600 m; Rated load voltage : DC 24 V; Reverse polarity protection of rated load voltage : Input voltage for signal "0" : DC 0...5 V; Input voltage for signal "1" : DC 15...28.8 V; Input resistance : 2 kΩ; Input current for signal "1" : 14 mA; Input delay of "0" to "1" : 0.8 µs; Input delay of "1" to "0" : 0.8 µs; Number of simultaneously utilizable inputs horizontal configuration : 6; Number of simultaneously utilizable inputs vertical configuration : 6; Initial data size : 10 Byte; Number of outputs : 2; Cable length, shielded : 1000 m; Cable length, unshielded : 600 m; Rated load voltage : DC 24 V; Reverse polarity protection of rated load voltage : Current consumption from load voltage L+ (without load) : 10 mA; Total current per group, vertical configuration : 2 A; Output voltage signal "1" at min. current : L+ (-125 mV); Output voltage signal "1" at max. current : L+ (-0.8 V); Output current at signal "1", rated value : 1 A; Output delay of "0" to "1" : max. 100 µs; Output delay of "1" to "0" : max. 500 µs; Lamp load : 10 W; Parallel switching of outputs for redundant control of a load : not possible; Parallel switching of outputs for increased power : not possible; Switching frequency with resistive load : max. 1000 Hz; Switching frequency with inductive load : max. 0.5 Hz; Switching frequency on lamp load : max. 10 Hz; Internal limitation of inductive shut-off voltage : L+ (-52 V); Short-circuit protection of output : yes, electronic; Trigger level : 3 A; Output data size : 10 Byte; Number of counters : 2; Counter width : 1x32 Bit / 2x16 Bit; Maximum input frequency : 1 MHz; Maximum count frequency : 1 MHz; Mode incremental encoder : Mode pulse / direction : Mode pulse : Mode frequency counter : Mode period measurement : Gate input available : Reset input available : Counter output available : Status display : yes; Interrupts : no; Process alarm : no; Diagnostic interrupt : no; Diagnostic functions : no; Diagnostics information read-out : none; Supply voltage display : yes; Group error display : red LED; Channel error display : none; Between channels and backplane bus : Insulation tested with : DC 500 V; Input bytes : 10; Output bytes : 10; Parameter bytes : 4; Diagnostic bytes : 0; Material : PPE / PA 6.6; Mounting : Profile rail 35 mm; Dimensions (WxHxD) : 25.4 mm x 76 mm x 78 mm; Net weight : 230 g; Operating temperature : 0 °C to 60 °C; Storage temperature : -25 °C to 70 °C; UL certification : yes