SD0523 ifmSDD11DGXFPKG/US-100

Compressed air meter; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 1; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max. voltage drop switching output DC [V] : 2; Permanent current rating of switching output DC [mA] : 250; (per output); Number of analogue outputs : 1; Analogue current output [mA] : 4...20; (scalable); Max. load [Ω] : 500; Pulse output : consumed quantity meter; Short-circuit protection : yes; Type of short-circuit protection : pulsed; Overload protection : yes; Measuring range : Measuring/setting range; Flow monitoring; The values apply at: Ø 72 mm; Measuring range : 0.5...143.9 m/s: 8...2110 m³/h: 0.12...35.18 m³/min; Display range : 0...172.7 m/s: 0...2532 m³/h: 0...42.22 m³/min; Resolution : 0.1 m/s: 2 m³/h: 0.02 m³/min; Set point SP : 1.2...143.9 m/s: 18...2110 m³/h: 0.28...35.18 m³/min; Reset point rP : 0.5...143.2 m/s: 6...2100 m³/h: 0.12...35 m³/min; Analogue start point ASP : 0...107.9 m/s: 0...1582 m³/h: 0...26.38 m³/min; Analogue end point AEP : 36...143.9 m/s: 528...2110 m³/h: 8.8...35.18 m³/min; In steps of : 0.1 m/s: 2 m³/h: 0.02 m³/min; Pulse value : 1...1000 x 10³; In steps of : 1 Nm³; Pulse length [s] : 0,7...2 (D = 72 mm); Dynamic response T05 / T09 [s] : 30 (Q > 2 Nm³/h); Response time [s] : 0.1; (dAP = 0); Damping for the switching output dAP in steps [s] : 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1; Parameter setting options : Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser; Communication interface : IO-Link; Transmission type : COM2 (38,4 kBaud); IO-Link revision : 1.1; SDCI standard : IEC 61131-9; Profiles : Smart Sensor: Process Data Variable; Device Identification; SIO mode : yes; Required master port type : A; Process data analogue : 3; Process data binary : 2; Min. process cycle time [ms] : 5; Supported DeviceIDs : Type of operation: DeviceID | Default: 381; Ambient temperature [°C] : 0...60; Storage temperature [°C] : -20...85; Max. relative air humidity [%] : 90; Materials : PBT-GF20; PC; stainless steel (1.4301 / 304); FKM; Materials (wetted parts) : stainless steel (1.4401 / 316); stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM; Process connection : threaded connection G 1 internal thread

Tipo
Sensores de caudal / caudalímetros
Conexión
Connector: 1 x M12
Número de entradas/salidas
Number of digital outputs: 2; Number of analogue outputs: 1
Consumo actual
< 110 mA
Suministro de voltaje
24 V
Mostrar
Display unit: 4 x LED, green (Nm³/min, Nm³/h, Nm³, °C) | function display: 1 x LED, green | switching status: 2 x LED, yellow | measured values: alphanumeric display, 4-digit | programming: alphanumeric display, 4-digit
Grado de protección
IP 65
Peso
539.5 g
Dimensiones
Ø 58 / L = 80.2 mm