Signal conditioners with functional safety Items 1 - 54 of 54 ⍾ Phoenix Contact ⍾ Last modified
Signal conditioners with functional safety ⍾ Page 1
-
IFS-USB-PROG-ADAPTER
Programming adapter with USB interface, for programming with software. The USB driver is included in the software solutions for the products to be programmed, such as measuring tra …
-
MACX MCR-UI-UI-UP-NC
Isolating amplifier with safe electrical isolation and wide-range power supply (24 V ... 230 V AC/DC). DIP switches on the front, over 1600 signal conversions can be set. Standard …
-
MACX MCR-T-UIREL-UP
Temperature measuring transducer - MACX MCR-T-UIREL-UP - 2811378; Freely programmable temperature transducer with analog output and 3 limit value relays, standard configuration, re …
-
MACX MCR-T-UI-UP
Freely programmable temperature measuring transducer with analog output and 1 limit value relay, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, wide-ra …
-
MACX MCR-UI-UI-NC
Configurable 3-way isolating amplifier with safe electrical isolation, 24 V, power bridging. DIP switches on the front, over 1600 signal conversions can be set. Standard configurat …
-
MACX MCR-UI-UI-SP-NC
Signal conditioner - MACX MCR-UI-UI-SP-NC - 2811556; Configurable 3-way isolating amplifier with safe electrical isolation, 24 V, power bridging. DIP switches on the front, over 16 …
-
MACX MCR-UI-UI-UP-SP-NC
Isolating amplifier with safe electrical isolation and wide-range power supply (24 V ... 230 V AC/DC). DIP switches on the front, over 1600 signal conversions can be set. Standard …
-
MACX MCR-UI-UI-SP
Configurable 3-way isolating amplifier with safe electrical isolation, 24 V, power bridging. DIP switches on the front, over 1600 signal conversions can be set. Order configuration …
-
MACX MCR-T-UIREL-UP-SP
Temperature measuring transducer - MACX MCR-T-UIREL-UP-SP - 2811828; Freely programmable temperature transducer with analog output and 3 limit value relays, standard configuration, …
-
MACX MCR-T-UI-UP-SP
Temperature measuring transducer - MACX MCR-T-UI-UP-SP - 2811860; Freely programmable temperature transducer with analog output and 1 limit value relay, standard configuration, res …
-
IFS-OP-CRADLE
Adapter module - IFS-OP-CRADLE - 2811886; The adapter (IFS-OP-CRADLE) for the operator interface is ideal for use as a remote operator panel and display device for 17.5 mm / 35 mm …
-
IFS-OP-UNIT
Operator interface - IFS-OP-UNIT - 2811899; The operator interface facilitates straightforward parameterization and operation of the MACX MCR(-EX)-...-UI(REL)(-UP) on-site, even wi …
-
MACX MCR-SL-NAM-2RO
Isolation amplifier - MACX MCR-SL-NAM-2RO - 2865010; NAMUR signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level using 2 …
-
MACX MCR-SL-NAM-2T
Isolation amplifier - MACX MCR-SL-NAM-2T - 2865023; NAMUR signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via 2 tr …
-
MACX MCR-SL-2NAM-T
Isolation amplifier - MACX MCR-SL-2NAM-T - 2865036; NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control leve …
-
MACX MCR-SL-2NAM-RO
Isolation amplifier - MACX MCR-SL-2NAM-RO - 2865049; NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transferred to the control lev …
-
MACX MCR-SL-2NAM-R-UP
Isolation amplifier - MACX MCR-SL-2NAM-R-UP - 2865052; 2-channel NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal output …
-
MACX MCR-SL-RTD-I-NC
Temperature measuring transducer - MACX MCR-SL-RTD-I-NC - 2865078; Temperature transducer, converts signals from resistance thermometers and resistors into 0/4 - 20 mA signals. Fre …
-
MACX MCR-PTB
Power and error message module - MACX MCR-PTB - 2865625; Power and fault signaling module with screw connection, including corresponding ME 17,5 TBUS 1,5/ 5-ST-3,81 GY DIN rail con …
-
MACX MCR-SL-RPSSI-I
Repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4 … 20 mA signals to a load (active or passive). 3-way electrical isolation, SI …
-
MACX MCR-SL-RPSSI-I-UP
Repeater power supply - MACX MCR-SL-RPSSI-I-UP - 2865968; Repeater power supply for supplying 2 and 3-conductor transmitters with HART transmission and wide range power supply, SIL …
-
MACX MCR-SL-IDSI-I
Output signal conditioner - MACX MCR-SL-IDSI-I - 2865971; Output signal conditioner, HART. Isolates and transfers 0/4-20 mA signals to a load (I/P converters, control valves, displ …
-
MACX MCR-SL-NAM-R
Isolation amplifier - MACX MCR-SL-NAM-R - 2865997; NAMUR signal conditioners for operating proximity sensors and switches. The signals are transmitted to the control level via rela …
-
MACX MCR-SL-RPSS-2I-2I
Signal isolator - MACX MCR-SL-RPSS-2I-2I - 2904089; 2-channel repeater power supply for operating 2-wire measuring transducers, input: 4…20 mA (powered), output: 4…20 mA (active), …
-
MACX MCR-SL-RPSS-2I-2I-SP
2-channel repeater power supply for operating 2-conductor measuring transducers, input: 4 ... 20 mA (supplying), output: 4 ... 20 mA (active), bidirectional transmission with digit …
-
TC-C-MAX2-SC-32220000
Cable set - TC-C-MAX2-SC-32220000 - 2904446; Cable set for signal transmission and power supply on the Termination Carrier for signal conditioners from the MACX Analog Ex series. C …
-
TC-C-MAX2-SC-31322122
Cable set - TC-C-MAX2-SC-31322122 - 2904674; Cable set for signal transmission on the Termination Carrier for two-channel modules or modules with double output from the MACX Analog …
-
TC-C-PTB3-SC-SET1
Cable set - TC-C-PTB3-SC-SET1 - 2905216; Cable set for TC-MACX-MCR-PTB power and fault signaling module (Order No. 2904673), for use on the Termination Carrier for signal condition …
-
MACX MCR-SL-I-I-ILP
Input loop-powered passive isolator with increased isolating voltage for electrical isolation of 0 mA/4 mA ... 20 mA signals. Input signal = output signal. number of channels: 1, S …
-
MACX MCR-SL-I-I-ILP-SP
Loop-powered isolators - MACX MCR-SL-I-I-ILP-SP - 2905279; Single-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analo …
-
MACX MCR-SL-2I-2I-ILP
Loop-powered isolators - MACX MCR-SL-2I-2I-ILP - 2905280; Two-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analog si …
-
MACX MCR-SL-2I-2I-ILP-SP
Loop-powered isolators - MACX MCR-SL-2I-2I-ILP-SP - 2905281; Two-channel input loop-powered 2-way isolator with plug-in connection technology for the electrical isolation of analog …
-
MACX MCR-I20
Plug - MACX MCR-I20 - 2905680; Connection terminal block for current signals, +20 mA ... -20 mA, for safe switching of limit values, in combination with MACX ...-T-UI... temperatur …
-
MACX MCR-SL-UI-REL
Limit value switches - MACX MCR-SL-UI-REL - 2906169; Limit value switch with input for active current and voltage signals and a limit-value relay output (changeover contact). Can b …
-
MACX MCR-SL-UI-REL-SP
Limit value switches - MACX MCR-SL-UI-REL-SP - 2906170; Limit value switch with input for active current and voltage signals and a limit-value relay output (changeover contact). Ca …
-
MACX MCR-SL-I-I-HV-ILP
Loop-powered isolators - MACX MCR-SL-I-I-HV-ILP - 2907704; Single-channel input loop-powered 2-way isolator with increased cut-off voltage and plug-in connection technology for the …
-
MACX MCR-SL-I-I-HV-ILP-SP
Loop-powered isolators - MACX MCR-SL-I-I-HV-ILP-SP - 2907705; Single-channel input loop-powered 2-way isolator with increased cut-off voltage and plug-in connection technology for …
-
MACX MCR-SL-2I-2I-HV-ILP
Loop-powered isolators - MACX MCR-SL-2I-2I-HV-ILP - 2907706; Two-channel input loop-powered 2-way isolator with increased cut-off voltage and plug-in connection technology for the …
-
MACX MCR-SL-2I-2I-HV-ILP-SP
Loop-powered isolators - MACX MCR-SL-2I-2I-HV-ILP-SP - 2907707; Two-channel input loop-powered 2-way isolator with increased cut-off voltage and plug-in connection technology for t …
-
-
MACX MCR-SL-RPSSI-I-SP
Repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0/4 … 20 mA signals to a load (active or passive). 3-way electrical isolation, SI …
-
MACX MCR-SL-RPSSI-I-UP-SP
Repeater power supply - MACX MCR-SL-RPSSI-I-UP-SP - 2924210; Repeater power supply for supplying 2 and 3-conductor transmitters with HART transmission and wide range power supply, …
-
MACX MCR-SL-IDSI-I-SP
Output signal conditioner - MACX MCR-SL-IDSI-I-SP - 2924223; Output signal conditioner, HART. Isolates and transmits 0/4-20 mA signals to a load (I/P converters, control valves, di …
-
MACX MCR-SL-NAM-R-SP
Isolation amplifier - MACX MCR-SL-NAM-R-SP - 2924252; NAMUR isolation amplifier for operating proximity sensors and switches. The signals are transferred to the control level using …
-
MACX MCR-SL-NAM-2RO-SP
Isolation amplifier - MACX MCR-SL-NAM-2RO-SP - 2924265; NAMUR signal conditioner for operating proximity sensors and switches. The signals are transferred to the control level usin …
-
MACX MCR-SL-NAM-2T-SP
Isolation amplifier - MACX MCR-SL-NAM-2T-SP - 2924278; NAMUR signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via 2 …
-
MACX MCR-SL-2NAM-T-SP
Isolation amplifier - MACX MCR-SL-2NAM-T-SP - 2924281; NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control l …
-
MACX MCR-SL-2NAM-RO-SP
Isolation amplifier - MACX MCR-SL-2NAM-RO-SP - 2924294; NAMUR 2-channel signal conditioner for operating proximity sensors and switches. The signals are transferred to the control …
-
MACX MCR-SL-2NAM-R-UP-SP
Isolation amplifier - MACX MCR-SL-2NAM-R-UP-SP - 2924304; 2-channel NAMUR signal conditioner with wide range power supply for proximity sensors and switches. In terms of signal out …
-
MACX MCR-SL-RTD-I-SP-NC
Temperature measuring transducer - MACX MCR-SL-RTD-I-SP-NC - 2924320; Temperature transducer, converts signals from resistance thermometers and resistors into 0/4 - 20 mA signals. …
-
MACX MCR-SL-TC-I-NC
Temperature measuring transducer - MACX MCR-SL-TC-I-NC - 2924346; Temperature transducer, converts signals from thermocouples and linear mV sources into 0/4-20 mA signals. Freely p …
-
MACX MCR-SL-RPSSI-2I
Measuring transducer repeater power supply and input signal conditioner transmits supplied or active 0 mA/4 mA ... 20 mA electrically isolated signals from the field to two loads. …
-
MACX MCR-SL-RPSSI-2I-SP
Repeater power supply - MACX MCR-SL-RPSSI-2I-SP - 2924838; Measuring transducer repeater power supply and input signal conditioner, HART-transparent. Transmits supplied or active 0 …
-
MACX MCR-CJC
Plug - MACX MCR-CJC - 2924993; Plug for cold junction compensation for thermocouples, for safe switching of limit values, in combination with MACX ...-T-UI... temperature transduce …