Sensor technology Items 673 - 768 of 784 ⍾ PILZ ⍾ Last modified
Sensor technology ⍾ Page 8
-
PSEN sg2c-5LPLLC switch
Safety gate system, safe interlock and safe guard locking device For; applications up to SIL CL 3 and PL e. Consisting of 5 pushbuttons: 1.; Illuminated pushbutton for activating t …
-
PSEN sg2c-5LPLLC unit
Safety gate system, safe interlock and safe guard locking device For; applications up to SIL CL 3 and PL e. Consisting of 5 pushbuttons: 1.; Illuminated pushbutton for activating t …
-
PSEN sg2c-5LPLLE 2.2 unit
Safety gate system, safe interlock and safe guard locking device For; applications up to SIL CL 3 and PL e. Coding: fully coded. 5; pushbuttons: 1. Illuminated pushbutton for activ …
-
PSEN sg2c-5LPLLE switch
Safety gate system, safe interlock and safe guard locking device For; applications up to SIL CL 3 and PL e. Consisting of 5 pushbuttons: 1.; Illuminated pushbutton for activating t …
-
-
PSEN sg2c-5LPLLS switch
Safety gate system, safe interlock and safe guard locking device For; applications up to SIL CL 3 and PL e. Consisting of 5 pushbuttons: 1.; Illuminated pushbutton for activating t …
-
PSEN sg2c-5LPLLS unit
Safety gate system, safe interlock and safe guard locking device For; applications up to SIL CL 3 and PL e. Consisting of 5 pushbuttons: 1.; Illuminated pushbutton for activating t …
-
-
-
-
-
-
-
PSEN sl-0.5 2.1 1actuator
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: fully coded, IP67, package contents = 1 standard actua …
-
PSEN sl-0.5fm 1.1 1actuator
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: coded,; IP67, package contents = 1 free-moving actuato …
-
PSEN sl-0.5fm 2.1 1actuator
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: fully coded, IP67, package contents = 1 free-moving ac …
-
PSEN sl-0.5n 1.1 1switch
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: coded,; 5-pin M12 connector, 4 LEDs, IP67, package con …
-
PSEN sl-0.5n 1.1 / PSEN sl-0.5 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: coded,; 5-pin M12 connector, 4 LEDs, IP67, package con …
-
PSEN sl-0.5n 1.1 / PSEN sl-0.5fm 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: coded,; 5-pin M12 connector, 4 LEDs, IP67, package con …
-
PSEN sl-0.5n 2.1 1switch
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: fully coded, 5-pin M12 connector, 4 LEDs, IP67, packag …
-
PSEN sl-0.5n 2.1 / PSEN sl-0.5 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: fully coded, 5-pin M12 connector, 4 LEDs, IP67, packag …
-
PSEN sl-0.5n 2.1 / PSEN sl-0.5fm 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: fully coded, 5-pin M12 connector, 4 LEDs, IP67, packag …
-
PSEN sl-0.5n 2.2 / PSEN sl-0.5 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding:unique,; fully coded, 5-pin M12 connector, 4 LEDs, IP67 …
-
PSEN sl-0.5n 2.2 / PSEN sl-0.5fm 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding:unique,; fully coded, 5-pin M12 connector, 4 LEDs, IP67 …
-
PSEN sl-0.5p 1.1 1switch
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: coded,; 8-pin M12 connector, 4 LEDs, IP67, package con …
-
PSEN sl-0.5p 1.1 / PSEN sl-0.5 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: coded,; 8-pin M12 connector, 4 LEDs, IP67, package con …
-
PSEN sl-0.5p 1.1 / PSEN sl-0.5fm 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: coded,; 8-pin M12 connector, 4 LEDs, IP67, package con …
-
PSEN sl-0.5p 2.1 1switch
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: fully coded, 8-pin M12 connector, 4 LEDs, IP67, packag …
-
PSEN sl-0.5p 2.1 / PSEN sl-0.5 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: fully coded, 8-pin M12 connector, 4 LEDs, IP67, packag …
-
PSEN sl-0.5p 2.1 / PSEN sl-0.5fm 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: fully coded, 8-pin M12 connector, 4 LEDs, IP67, packag …
-
PSEN sl-0.5p 2.2 / PSEN sl-0.5 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding:unique,; fully coded, 8-pin M12 connector, 4 LEDs, IP67 …
-
PSEN sl-0.5p 2.2 / PSEN sl-0.5fm 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding:unique,; fully coded, 8-pin M12 connector, 4 LEDs, IP67 …
-
PSEN sl-0.5p 3.1
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: Coded,; add-on function: switch safe semiconductor out …
-
PSEN sl-0.5p 3.1 / PSEN sl-0.5 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: coded, add-on function: switch safe semiconductor outp …
-
PSEN sl-0.5p 3.1 / PSEN sl-0.5fm 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: Coded,; add-on function: switch safe semiconductor out …
-
PSEN sl-0.5p 4.1
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: fully coded, possible to teach-in other actuators (tot …
-
PSEN sl-0.5p 4.1 / PSEN sl-0.5 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: fully coded, possible to teach-in other actuators (tot …
-
PSEN sl-0.5p 4.1 / PSEN sl-0.5fm 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: fully coded, possible to teach-in other actuators (tot …
-
PSEN sl-0.5p 4.2 / PSEN sl-0.5 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding:unique,; fully coded, add-on function: switch safe semi …
-
PSEN sl-0.5p 4.2 / PSEN sl-0.5fm 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding:unique,; fully coded, add-on function: switch safe semi …
-
PSEN sl-0.5p 6.1
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: fully coded, add-on function: Expanded diagnostic func …
-
PSEN sl-0.5p 6.1/PSEN sl-0.5 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: fully coded, add-on function: Expanded diagnostic func …
-
PSEN sl-0.5p 6.1/PSEN sl-0.5fm 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 500N (process protection). Coding: fully coded, add-on function: Expanded diagnostic func …
-
-
PSEN sl-1.0 2.1 1actuator
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: fully coded, IP67, package contents = 1 standard actu …
-
PSEN sl-1.0fm 1.1 1actuator
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: coded, IP67, package contents = 1 free-moving actuato …
-
PSEN sl-1.0fm 2.1 1actuator
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: fully coded, IP67, package contents = 1 free-moving a …
-
PSEN sl-1.0n 1.1 1switch
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: coded, 5-pin M12 connector, 4 LEDs, IP67, package con …
-
PSEN sl-1.0n 1.1 / PSEN sl-1.0 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: coded, 5-pin M12 connector, 4 LEDs, IP67, package con …
-
PSEN sl-1.0n 1.1 / PSEN sl-1.0fm 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: coded, 5-pin M12 connector, 4 LEDs, IP67, package con …
-
PSEN sl-1.0n 2.1 1switch
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: fully coded, 5-pin M12 connector, 4 LEDs, IP67, packa …
-
PSEN sl-1.0n 2.1 / PSEN sl-1.0 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: fully coded, 5-pin M12 connector, 4 LEDs, IP67, packa …
-
PSEN sl-1.0n 2.1 / PSEN sl-1.0fm 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: fully coded, 5-pin M12 connector, 4 LEDs, IP67, packa …
-
PSEN sl-1.0n 2.2 / PSEN sl-1.0 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding:unique,; fully coded, 5-pin M12 connector, 4 LEDs, IP6 …
-
PSEN sl-1.0n 2.2 / PSEN sl-1.0fm 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding:unique,; fully coded, 5-pin M12 connector, 4 LEDs, IP6 …
-
PSEN sl-1.0p 1.1 1switch
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: coded, 8-pin M12 connector, 4 LEDs, IP67, package con …
-
PSEN sl-1.0p 1.1 / PSEN sl-1.0 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: coded, 8-pin M12 connector, 4 LEDs, IP67, package con …
-
PSEN sl-1.0p 1.1 / PSEN sl-1.0fm 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: coded, 8-pin M12 connector, 4 LEDs, IP67, package con …
-
PSEN sl-1.0p 1.1 VA 1switch
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: coded, 8-pin M12 connector, special model: Stainless …
-
PSEN sl-1.0p 1.1 VA/PSEN sl-1.0 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: coded, 8-pin M12 connector, special model: Stainless …
-
PSEN sl-1.0p 2.1 1switch
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: fully coded, 5-pin M12 connector, 4 LEDs, IP67, packa …
-
-
PSEN sl-1.0p 2.1 / PSEN sl-1.0fm 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: fully coded, 8-pin M12 connector, 4 LEDs, IP67, packa …
-
-
PSEN sl-1.0p 2.2 / PSEN sl-1.0fm 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding:unique,; fully coded, 8-pin M12 connector, 4 LEDs, IP6 …
-
PSEN sl-1.0p 3.1
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: coded, add-on function: switch safe semiconductor out …
-
PSEN sl-1.0p 3.1 / PSEN sl-1.0 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: coded, add-on function: switch safe semiconductor out …
-
PSEN sl-1.0p 3.1 / PSEN sl-1.0fm 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: coded, add-on function: switch safe semiconductor out …
-
PSEN sl-1.0p 4.1
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: fully coded, possible to teach-in other actuators (to …
-
PSEN sl-1.0p 4.1 / PSEN sl-1.0 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: fully coded, possible to teach-in other actuators (to …
-
PSEN sl-1.0p 4.1 / PSEN sl-1.0fm 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: fully coded, possible to teach-in other actuators (to …
-
PSEN sl-1.0p 4.2 / PSEN sl-1.0 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding:unique,; fully coded, add-on function: switch safe sem …
-
PSEN sl-1.0p 4.2 / PSEN sl-1.0fm 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding:unique,; fully coded, add-on function: switch safe sem …
-
PSEN sl-1.0p 6.1
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: fully coded, add-on function: Expanded diagnostic fun …
-
PSEN sl-1.0p 6.1/PSEN sl-1.0 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: fully coded, add-on function: Expanded diagnostic fun …
-
PSEN sl-1.0p 6.1/PSEN sl-1.0fm 1unit
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: fully coded, add-on function: Expanded diagnostic fun …
-
PSEN sl-1.0 VA 1actuator
Magnetic safety gate system for applications up to SIL3/PL; e/Cat4. Magnetic holding force 1000N (process protection). Coding: coded, special model: Stainless steel base plates (1. …
-
PSEN sl2-DL1-N switch
Safety switch with electromagnetic guard locking, coded, for safety guard locking device PSENslock2, guard locking for processprotection, holding force 2000 N, 5-pin M12 male conne …
-
PSEN sl2-DL3-P switch
Safety switch with electromagnetic guard locking, uniquely coded, for safety guard locking device PSENslock2, guard locking for processprotection, holding force 2000 N, 8-pin M12 m …
-
PSEN sl2-DM1-P switch
Safety switch with electromagnetic guard locking, coded, for safety guard locking device PSENslock2, guard locking for processprotection, holding force 1000 N, 8-pin M12 male conne …
-
-
-
-
-
PSEN sl restart interlock (padlock)
Accessories for PSENslock with "restart interlock” function to; protect work within the danger zone of a machine that is shut down.; Mechanical add-on module for attachment to PSEN …
-
-
-
-
-
-
-
-
PSENvip AT spring mount
Adjustment template to position between the upper and lower tool. To; align PSENvip during installation and tool change. PL e, SIL 3.; Approved in accordance with IEC 61496-1 and E …
-
-
-