DFS60B-TH / DFS60 Page 2 from SICK ⍾ Last modified
dfs60b-th / DFS60 ⍾ Page 2
-
DFS60B-THCK02500
Performance: Pulses per revolution: 2,500 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interf …
-
DFS60B-THCL04096
Performance: Pulses per revolution: 4,096 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interface …
-
DFS60B-THCL08192
Performance: Pulses per revolution: 8,192 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interface …
-
DFS60B-THCM01250
Performance: Pulses per revolution: 1,250 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interf …
-
DFS60B-THEA01024
Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interface …
-
DFS60B-THEA01500
Performance: Pulses per revolution: 1,500 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interf …
-
DFS60B-THEA04096
Performance: Pulses per revolution: 4,096 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interface …
-
DFS60B-THEK00128
Performance: Pulses per revolution: 128 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interfaces: …
-
DFS60B-THEK00360
Performance: Pulses per revolution: 360 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfac …
-
DFS60B-THEK04096
Performance: Pulses per revolution: 4,096 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interface …
-
DFS60B-THEL01024
Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interface …
-
DFS60B-THEN00400
Performance: Pulses per revolution: 400 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfac …