DFS60B-S4E / DFS60 Page 1 from SICK ⍾ Last modified
dfs60b-s4e / DFS60 ⍾ Page 1
-
DFS60B-S4EA00015
Performance: Pulses per revolution: 15 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.08°; Error limits: ± 0.05°; Interface …
-
DFS60B-S4EA00016
Performance: Pulses per revolution: 16 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.05°; Error limits: ± 0.05°; Interfaces: C …
-
DFS60B-S4EA00020
Performance: Pulses per revolution: 20 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.08°; Error limits: ± 0.05°; Interface …
-
DFS60B-S4EA00030
Performance: Pulses per revolution: 30 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.08°; Error limits: ± 0.05°; Interface …
-
DFS60B-S4EA00036
Performance: Pulses per revolution: 36 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.08°; Error limits: ± 0.05°; Interface …
-
DFS60B-S4EA00040
Performance: Pulses per revolution: 40 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.08°; Error limits: ± 0.05°; Interface …
-
DFS60B-S4EA00090
Performance: Pulses per revolution: 90 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.08°; Error limits: ± 0.05°; Interface …
-
DFS60B-S4EA00124
Performance: Pulses per revolution: 124 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfac …
-
DFS60B-S4EA00180
Performance: Pulses per revolution: 180 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfac …
-
DFS60B-S4EA00230
Performance: Pulses per revolution: 230 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfac …
-
DFS60B-S4EA00240
Performance: Pulses per revolution: 240 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfac …
-
DFS60B-S4EA00377
Performance: Pulses per revolution: 377 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfac …