7MF4033-1BA00-2EB7-Z C11+C12+C20+Y01+Y21
SIEMENS ⍾ 7MF40331BA002EB7ZC11C12C20Y01Y21
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,01 ... 1 bar g (0.15 ... 14.5 psi g), overload limit 6 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing International design english inscription and documentation as cd Ex nA/ic - Use in Zone 2 Electric connection and cable inlet: cable gland M20 x 1.5 Housing cover with window (digital indicator visible, customized adjustment supplement Y21 required) Test certificate according to standard IEC 60770-2 Inspection certificate EN 10204-3.1: certificate pressurised parts Functional safety SIL2. Devices suitable for use according to IEC 61508 and IEC 61511. Includes SIL conformity declaration. Range (linear characteristic) specify in plain text:, Y01:... to ...mBar,kpa,mpa,... Adjustment digital indicator specify plain text Y21: mBar, bar, kpa, mpa,...
- Typ
- Przetworniki ciśnienia DSIII