Interfejsy sterowania RFID Produkty 1 - 27 z 27 ⍾ Pepperl+Fuchs ⍾ Aktualizowano
Interfejsy sterowania RFID ⍾ Strona 1
-
Base for read/write station U-P6-B6
Base for read/write station U-P6-B6; PROFIBUS DP acc. to EN 50170; 2 PG screw fittings for IN and OUT supply2 EMV PG screw fittings for BUS IN and OUT; Complete read/write function …
-
Base for read/write station U-P6-B5
Base for read/write station U-P6-B5; INTERBUS-remote bus subscriber; 2 PG screw fittings for IN and OUT supply2 EMV PG screw fittings for BUS IN and OUT; Complete read/write functi …
-
-
-
-
-
Base for read/write station U-P6-B5-V
Base for read/write station U-P6-B5-V; Bus subscriber for INTERBUS installation; 500 kBit/s or 2 MBit/s transfer rate (switchable); M23 round connection for BUS and supply; Complet …
-
Control interface unit IC-KP-B6-V15B
Control interface unit IC-KP-B6-V15B; Max. 4 read/write heads connectable; Alternative 2 read/write heads and 2 trigger sensors can be connected; LC display with background lightni …
-
-
Control interface unit IC-KP-R2-V1
Control interface unit IC-KP-R2-V1; Max. 4 read/write heads connectable; Alternative 2 read/write heads and 2 trigger sensors can be connected; LC display with background lightning …
-
Base for read/write station, stainless steel version U-P3V4A-RX
Base for read/write station, stainless steel version U-P3V4A-RX; high-grade steel housing V4A; With serial interfaces RS 232 and RS 485; Degree of protection IP67; Resistant agains …
-
Base for read/write station, stainless steel version U-P6V4A-B6
Base for read/write station, stainless steel version U-P6V4A-B6; PROFIBUS DP acc. to EN 50170; 2 PG screw fittings for IN and OUT supply2 EMV PG screw fittings for BUS IN and OUT; …
-
Control interface unit IC-KP-B6-SUBD
Control interface unit IC-KP-B6-SUBD; Max. 4 read/write heads connectable; Alternative 2 read/write heads and 2 trigger sensors can be connected; LC display with background lightni …
-
Base for read/write station U-P6-B6-V15B
Base for read/write station U-P6-B6-V15B; PROFIBUS DP acc. to EN 50170; M12 round connection for supply; M12 round connection for BUS (B-coded); Complete read/write functionality v …
-
Control interface unit IC-KP-B7-V95
Control interface unit IC-KP-B7-V95; Max. 4 read/write heads connectable; Alternative 2 read/write heads and 2 trigger sensors can be connected; LC display with background lightnin …
-
Base for read/write station, stainless steel version U-P7V4A-R4
Base for read/write station, stainless steel version U-P7V4A-R4; Simple bus system with up to 30 units; high-grade steel housing V4A; Serial interface RS 485, addressable; Degree o …
-
Control interface unit IC-KP-B6-2V15B
Control interface unit IC-KP-B6-2V15B; Max. 4 read/write heads connectable; Alternative 2 read/write heads and 2 trigger sensors can be connected; LC display with background lightn …
-
-
RFID evaluation unit IC-KP2-2HB6-V15B
Control interface unit IC-KP2-2HB6-V15B; LED status indicator of bus communication and read/write heads; Max. 2 read/write heads can be connected; Alternatively 1 read/write head a …
-
-
Control interface unit IC-KP2-2HB17-2V1D
Control interface unit IC-KP2-2HB17-2V1D; LED status indicator of bus communication and read/write heads; Network loop through by means of integrated 2 port switch; Max. 2 read/wri …
-
-
Control interface unit IC-KP2-2HRX-2V1
Control interface unit IC-KP2-2HRX-2V1; LED status indicator of bus communication and read/write heads; Max. 2 read/write heads can be connected; Alternatively 1 read/write head an …
-
RFID evaluation unit IC-KP-B17-AIDA1
Control interface unit IC-KP-B17-AIDA1; Max. 4 read/write heads connectable; Alternative 2 read/write heads and 2 trigger sensors can be connected; LED status indicator of bus comm …
-
-
Control interface unit IC-KP2-2HB18-2V1
Control interface unit IC-KP2-2HB18-2V1; LED status indicator of bus communication and read/write heads; Max. 2 read/write heads can be connected; Alternatively 1 read/write head a …
-
Control interface unit IC-KP2-2HB21-2V1D
Control interface unit IC-KP2-2HB21-2V1D; LED status indicator of bus communication and read/write heads; Max. 2 read/write heads can be connected; Alternatively 1 read/write head …