DFS60B-THEC10000 SICK ⍾ 1063532
DFS60, Rotary. Electrical interface: 10 V ... 32 V, HTL/Push pull, Connector M12, 8-pin, radial.
SICK DFS60B-THEC10000 Datasheet PDF Size: 570 KB |
Download |
Related in dfs60b-th / DFS60 ⍾ Page 1
-
DFS60B-THAA02048
Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interface …
-
DFS60B-THAC00720
Performance: Pulses per revolution: 720 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfac …
-
DFS60B-THAC05000
Performance: Pulses per revolution: 5,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interf …
-
DFS60B-THAK00250
Performance: Pulses per revolution: 250 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfac …
-
DFS60B-THAK00S96
Features: Special device: ✔; Specialty: Cable, 8-wire, universal, 1.5 m, customized cable connection (10 cm braided shield); Standard reference device: DFS60B-THAK10000, 1058444; P …
-
DFS60B-THAK02000
Performance: Pulses per revolution: 2,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interf …
-
DFS60B-THAK04096
Performance: Pulses per revolution: 4,096 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interface …
-
DFS60B-THCA02000
Performance: Pulses per revolution: 2,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interf …
-
DFS60B-THCA05000
Performance: Pulses per revolution: 5,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interf …
-
DFS60B-THCC04096
Performance: Pulses per revolution: 4,096 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.05°; Interface …
-
DFS60B-THCC10000
Performance: Pulses per revolution: 10,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Inter …
-
DFS60B-THCK00250
Performance: Pulses per revolution: 250 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.01°; Error limits: ± 0.05°; Interfac …