OY006S ifmOYA0910-14-4-06-P-1

Safety light curtain; Operating voltage tolerance [%] : 20; Operating voltage [V] : 24 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 2; Type of light : infrared light; Wave length [nm] : 950; Electrical design : PNP; Number of OSSD outputs : 2; Max. current load per OSSD output [mA] : 400; (24 V); Short-circuit protection : yes; Protected area height [mm] : 910; Resolution (detection capacity d) [mm] : 14; Protection area width (low light intensity) [m] : 0...3; Protection area width (high light intensity) [m] : 1...6; Response time [ms] : 13; Applications : class C to EN 60654-1 weatherproof application; Ambient temperature [°C] : -10...55; Max. relative air humidity [%] : 95; ESPE type (IEC 61496-1) : 4; ISO 13849-1 : category 4, PL e; IEC 61508 : SIL 3; IEC 62061 : SIL cl 3; Mission time TM [h] : 175200; Safety-related reliability PFHD [1/h] : 2.3E-08; Materials : housing: aluminium; front lens: PC; Length L [mm] : 963; Items supplied : mounting bracket: 4 | slot nuts: 4 | Nuts

Connection
Connector: 1 x M12
No. of inputs/outputs
Number of digital outputs: 2
Current consumption
42 mA
Voltage supply
24 V
Display
LED, yellow | LED, green | LED, red | LED, blue | LED, orange
Degree of protection
IP 65; IP 67
Weight
3400 g
Dimensions
963 x 28 x 30 mm