M31-1CD50 Yaskawa ⍾ M311CD50
M31-1CD50 - Signal modules analog | Analog input modules; Order no. : M31-1CD50; Type : SM M31; Module ID : 0417 1544; Features : 4x AI 16 Bit Voltage 0...10 V, -10 V…+10 V Current 0/4...20 mA Resistance 0....3000 Ohm, RTD, Pt100, Pt1000, NI100, NI1000 in 2/3/4 conductor measurement TC type J, K, N, R, S, T, B, C, E, L and U +/-80 mV; Current consumption from backplane bus : 150 mA; Power loss : 750 mW; Number of inputs : 4; Cable length, shielded : 200 m; Voltage inputs : Min. input resistance (voltage range) : 100 kΩ; Input voltage ranges : 0 V ... +10 V-10 V ... +10 V-80 mV ... +80 mV; Operational limit of voltage ranges : +/-0.3%; Operational limit of voltage ranges with SFU : +/-0.3%; Basic error limit voltage ranges : +/-0.2%; Basic error limit voltage ranges with SFU : +/-0.2%; Destruction limit voltage : max. 30V; Current inputs : Max. input resistance (current range) : 70 Ω; Input current ranges : 0 mA ... +20 mA+4 mA ... +20 mA; Operational limit of current ranges : +/-0.3%; Operational limit of current ranges with SFU : +/-0.3%; Basic error limit current ranges : +/-0.2%; Radical error limit current ranges with SFU : +/-0.2%; Destruction limit current inputs (voltage) : max. 30V; Destruction limit current inputs (electrical current) : max. 60mA; Resistance inputs : Resistance ranges : 0 ... 60 Ohm0 ... 600 Ohm0 ... 3000 Ohm; Operational limit of resistor ranges : +/-0.3%; Operational limit of resistor ranges with SFU : +/-0.3%; Basic error limit : +/-0.2%; Basic error limit with SFU : +/-0.2%; Destruction limit resistance inputs : max. 30V; Resistance thermometer inputs : Resistance thermometer ranges : Pt100Pt1000Ni100Ni1000; Operational limit of resistance thermometer ranges : +/-0.3%; Operational limit of resistance thermometer ranges with SFU : +/-0.3%; Basic error limit thermoresistor ranges : +/-0.2%; Basic error limit thermoresistor ranges with SFU : +/-0.2%; Destruction limit resistance thermometer inputs : max. 30V; Thermocouple inputs : Thermocouple ranges : type Jtype Ltype Ktype Ntype Rtype Stype Btype Ctype Etype T; Operational limit of thermocouple ranges : for type B: +/-14.6K; for type K, for type N: +/-1.,0K; for type S, for type R: +/-14.1K; for type T: +/-12.0K; for type C: +/-14.0K; for type E: +/-13.0K; for type J: +/-11.0K; for type L: +/-13.5K; Operational limit of thermocouple ranges with SFU : for type B: +/-14.6K; for type K, Typ N: +/-10.0K; for type S, for type R: +/-14.1K; for type T: +/-12.0K; for type C: +/-14.0K; for type E: +/-13.0K; for type J: +/-11.0K; for type L: +/-13.5K; Basic error limit thermoelement ranges : for type B: +/-14.6K; for type K, type N: +/-10.0K; for type S, for type R: +/-14.1K; for type T: +/-12.0K; for type C: +/-14.0K; for type E: +/-13.0K; for type J: +/-11.0K; for type L: +/-13.5K; Basic error limit thermoelement ranges with SFU : for type B: +/-14.6K; for type K, Typ N: +/-10.0K; for type S, type R: +/-14.1K; for type T: +/-12.0K; for type C: +/-14.0K; for type E: +/-13.0K; for type J: +/-11.0K; for type L: +/-13.5K; Destruction limit thermocouple inputs : max. 30V; Internal temperature compensation : Temperature error internal compensation : 8 K; Technical unit of temperature measurement : °C, °F, K; Resolution in bit : 16; Measurement principle : Sigma-Delta; Basic conversion time : 10ms … 200ms (for R/RTD & TC); Noise suppression for frequency : >80dB (UCM
- Type
- SLIO CPU