SIEMENS, Schneider Electric, Omron, Danfoss, IFM, WEINTEK components. Looking for other brand? Contact us.

Make :
SIEMENS
MPN :
7SK8042-5EB96-1HE0 L0D
Product ID :
7SK80425EB961HE0L0D

MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/ 0,005 TO 8A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V, AC 115V/ 230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) MODBUS, ELECTRICAL RS485 INTERFACE, PORT A (ON BOTTOM OF DEVICE) WITH ETHERNET INTERFACE (DIGSI, RTD BOX, NOT IEC61850) RJ45 CONNECTOR METERING: FAULT RECORDING FUNKTIONALITY: TOC PHASE OVERCURRENT (50/51) I>, I>>,I>>>,IP TIME OVERCURR.PROTECTION GROUND 50N/51N, IE>,IE>>,IE>>>,IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP, OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION LOCK OUT (86) STARTING TIME SUPERVISION (48) UNDERCURRENT MONITORING (37) RESTART INHIBIT (66/86) LOCKED ROTOR PROTECTION (14) LOAD JAM PROTECTION (51M) ADDITIONAL FUNCTIONS: DIRECT. SENSITIVE GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION

< 7SK8042-5EB90-3HE0 L0A | 7SK8042-5EB96-3HE0 L0A >

Related in 7SK80 • Page 1

7SK8011-5EB00-1HD0

SIEMENS 7SK8011-5EB00-1HD0

MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IE = 1A / 5A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V, AC 115V [...]

Read more
7SK8011-5EB26-1HD0

SIEMENS 7SK8011-5EB26-1HD0

MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IE = 1A / 5A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V, AC 115V [...]

Read more
7SK8012-5EB00-3HD0

SIEMENS 7SK8012-5EB00-3HD0

MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/ 0,005 TO 8A RATED AUXILIARY VOLTAGE D [...]

Read more
7SK8021-5EG16-1HD0

SIEMENS 7SK8021-5EG16-1HD0

MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IE = 1A / 5A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V, AC 115V [...]

Read more
7SK8022-5EB00-1HD0

SIEMENS 7SK8022-5EB00-1HD0

MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/ 0,005 TO 8A RATED AUXILIARY VOLTAGE D [...]

Read more
7SK8031-5EB90-1HE0 L0A

SIEMENS 7SK8031-5EB90-1HE0 L0A

MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 3 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IE = 1A / 5A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V,  [...]

Read more
7SK8031-5EB96-3HE0 L0A

SIEMENS 7SK8031-5EB96-3HE0 L0A

MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 3 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IE = 1A / 5A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V,  [...]

Read more
7SK8041-5EB10-1HE0

SIEMENS 7SK8041-5EB10-1HE0

MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IE = 1A / 5A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V,  [...]

Read more
7SK8041-5EB90-3HE0 L0A

SIEMENS 7SK8041-5EB90-3HE0 L0A

MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IE = 1A / 5A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V,  [...]

Read more
7SK8041-5EB96-1HE0

SIEMENS 7SK8041-5EB96-1HE0

MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT

Read more
7SK8041-5EB96-1HE0 L0A

SIEMENS 7SK8041-5EB96-1HE0 L0A

MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IE = 1A / 5A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V,  [...]

Read more
7SK8041-5EB96-3HD0

SIEMENS 7SK8041-5EB96-3HD0

MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT

Read more
7SK8041-5EB96-3HE0 L0R

SIEMENS 7SK8041-5EB96-3HE0 L0R

MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IE = 1A / 5A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/ 220V,  [...]

Read more
7SK8042-5EB90-1HE0 L0A

SIEMENS 7SK8042-5EB90-1HE0 L0A

MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/ 0,005 TO 8A RATED AUXILIARY VO [...]

Read more
7SK8042-5EB90-3HE0 L0A

SIEMENS 7SK8042-5EB90-3HE0 L0A

MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/ 0,005 TO 8A RATED AUXILIARY VO [...]

Read more
7SK8042-5EB96-3HE0 L0A

SIEMENS 7SK8042-5EB96-3HE0 L0A

MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/ 0,005 TO 8A RATED AUXILIARY VO [...]

Read more
7SK8042-5EB96-3HE0 L0S

SIEMENS 7SK8042-5EB96-3HE0 L0S

MOTOR PROTECTION RELAY HOUSING 1/6 19&quot;, 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/ 0,005 TO 8A RATED AUXILIA [...]

Read more
7SK8051-5EB26-1HD0

SIEMENS 7SK8051-5EB26-1HD0

MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 BI, 5 BO, (2 CHANGEOVER) 5 RTD INPUTS 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IE = 1A / 5A RATED AUXILIARY VOLTAGE DC 60V/ 110V / 125V/  [...]

Read more
7SK8052-5EB00-1HD0

SIEMENS 7SK8052-5EB00-1HD0

MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 BI, 5 BO, (2 CHANGEOVER) 5 RTD INPUTS 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/ 0,005 TO 8A RATED AUXILI [...]

Read more
7SK8062-1EC90-3HE0 L0D

SIEMENS 7SK8062-1EC90-3HE0 L0D

MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 3 BI, 5 BO, (2 CHANGEOVER) 5 RTD INPUTS 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/ 0,005 TO 8A RATED [...]

Read more
7SK8062-5EB90-3HE0 L0R

SIEMENS 7SK8062-5EB90-3HE0 L0R

MOTOR PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 3 BI, 5 BO, (2 CHANGEOVER) 5 RTD INPUTS 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A / 5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/ 0,005 TO 8A RATED [...]

Read more