7SD5221-5CB29-0GK0 M0A SIEMENS7SD52215CB290GK0M0A

TWO TERMINAL DIFFERENT. RELAY WITH 4-LINE DISPLAY MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/1 X 19", 16 BI, 23 BO, 1 LIVE-STATUS CONTACT REGION WORLD,LANGUAGE UK-ENGL. (LANGUAGE CHANGEABLE) IEC 60870-5-103,ELECTRIC. RS485 NO DIGSI INTERFACE ON REAR OF DEVICE, PROTECTION INTERFACE 1: OPTICAL 820NM,TWO ST-CONNECTORS FO LENGTH UP TO 1,5KM, FOR MULTIMODE FIBER FOR DIRECT CONNECTION OR COMMUNICATION NETWORKS FUNCTION 1: TRIP MODE 3-POLE ONLY, WITHOUT AUTO RECLOSURE FUNCTION WITHOUT SYNCHRONISM CHECK WITH TIME OVERCURRENT PROTECT. BREAKER FAILUR PROTECTION/ DISTANCE PROTECTION(PICKUP I>, -UI/PHI, -Z<), POLYGON, PARALLEL LINE COMP., POWER SWING DETECTION, DIRECTIONAL GROUND (EARTH)- FAULT PROTECTION WITH 4 REMOTE COMMANDS, WITH 24 REMOTE MESSAGES, WITHOUT TRANSFORMER EXTENSIONS FAULT LOCATOR 1-SIDE MEASURING WITH VOLTAGE-/FREQUENCY PROTEC. W/O MEASURED VALUES EXTENDED, W/O EXTERNAL GPS-SYNCHRONIZAT. WITHOUT CAPACITIVE CURRENT LOAD COMPENSATION

Related in 7SD ⍾ Page 1

  • 7SD5221-4NB99-9HJ0 L0R+M2G+N1G

    TWO TERMINAL DIFFERENT. RELAY WITH 4-LINE DISPLAY MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 60V TO 125V DC BINARY INPUT THRESHOLD 19V WITH 5 FAST TRIP CONTACTS, APPROX.  

  • 7SD5231-5AB09-9CJ4 M2G+N0G

    MULTITERMINAL DIFFERENT. RELAY WITH 4-LINE DISPLAY FOR MULTITERMINALS (3 TO 6) MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD  

  • 7SD5321-5PB99-9HV7 L0S+M3G+N7G

    TWO TERMINAL DIFFERENT. RELAY WITH GRAPHICAL DISPLAY MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V WITH 5 FAST TRIP CONTA 

  • 7SD5322-5DB99-9FP2 L0S+M2A+N0A

    Multi-end differential protection relay for two to six line ends, 4-line backlit display

  • 7SD6101-5BB99-0BJ0 L0R+M1A

    LINE-DIFFERENTIAL PROT. RELAY FOR TWO LINE TERMINALS CURRENT TRANSFORMER: IPH = 1A, IE = 1A AUXILIARY VOLTAGE: 110V-250V DC 115V TO 230V AC, BINARY INPUT THRESHOLD 88V, FLUSH-MOUNT 

  • 7SD6105-5BB99-0CN0 L0R+M2B

    LINE-DIFFERENTIAL PROT. RELAY FOR TWO LINE TERMINALS CURRENT TRANSFORMER: IPH = 5A, IE = 5A AUXILIARY VOLTAGE: 110V-250V DC 115V TO 230V AC, BINARY INPUT THRESHOLD 88V, FLUSH-MOUNT 

  • 7SD8011-5BB20-1FA0

    Line differential protection Enclosure 1/6 19", 4 x I, 3 BI, 5 BQ (2 changeover contacts) 1 live contact Interface FOC for mono (24 km)/multimode fiber (4 km), LC duplex plug Measu 

  • 7SD8031-1EB07-1FA1

    LINE-DIFFERENTIAL PROT. RELAY HOUSING 1/6 19", 4 X I, 5 BI, 8 BO, (2 CHANGEOVER/FORM C) 1 LIVE STATUS CONTACT PROTECTION DATA INTERFACE 2 WIRES COPPER, TWISTED MEASURING INPUTS: IP 

  • 7SD8061-5EB90-1FA0 L0R

    LINE-DIFFERENTIAL PROT. RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER/FORM C) 1 LIVE STATUS CONTACT PROTECTION DATA INTERF. FO FOR MONO- (24 KM) AND MULTIMODE (4 K 

  • 7SD8071-5BB20-1FA0

    Line differential protection Enclosure 1/6 19", 4 x I, 3 x U 5 BI, 8 BQ (2 changeover contacts) 1 live contact Interface copper (2-wire connection, twisted) Measuring inputs: Iph = 

  • 7SD8071-5EB20-1FA0

    Line differential protection Enclosure 1/6 19", 4 x I, 3 x U 5 BI, 8 BQ (2 changeover contacts) 1 live contact Interface copper (2-wire connection, twisted) Measuring inputs: Iph =