7MF4433-1CA02-1AA7-Z Y21 SIEMENS7MF44331CA021AA7ZY21

SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 1 to 60 mbar (0.4015 to 24.09 inH2O), max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18 npt mounting thread: M10 Die-cast aluminium housing, process flange bolts stainless steel Standard design . None explosion protection Electric connection and cable inlet: screwed gland PG 13.5 Housing cover with window customized adjustment supplement Y21 required Adjustment digital indicator specify in plain text Y21: mBar, bar, kpa, mpa, ...