3WL1106-2DG45-4GA2 SIEMENS3WL11062DG454GA2

withdrawable circuit breaker without guide frame 4-pole, size I, IEC In=630A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated Motorized/manual operating mechanism with memory Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC

Related in 3WL ⍾ Page 1

  • 3WL1106-2AA45-4GA2

    withdraw. non-aut. circuit-b. without guide frame 4-pole, size I, IEC In=630A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal without overcurrent release Motorized/m 

  • 3WL1106-2CB36-1AA2

    withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=630A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection a 

  • 3WL1106-2CB38-4GA4-Z C01+C22+K07+R10+R15+R21+S07

    Draw-out circuit breaker with slide-in module frame 3-pole, Size 1, IEC In=630 A to 690 V, 50/60 Hz AC Icu=55 kA at 500 V with connecting flange Overcurrent release ETU 25 LSI prot 

  • 3WL1106-2DG45-4GA4-Z C22+F23+F40+K07

    withdrawable circuit breaker without guide frame 4-pole, size I, IEC In=630A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protect 

  • 3WL1106-2EB36-1AA2

    withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=630A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection  

  • 3WL1106-2NG32-4GG2

    fixed-mounted circuit breaker 3-pole, size I, IEC In=630A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 76 LSING protection adjustable 0.4- 

  • 3WL1106-2NG47-4GG2

    withdrawable circuit breaker with guide frame 4-pole, size I, IEC In=630A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 76 LSING protection a 

  • 3WL1106-3..31-....

    FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL

  • 3WL1106-3..32-....

    FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL

  • 3WL1106-3..33-....

    FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=66KA AT 500V FRNT.CONN. TOP/BOT. SINGLE-HOLE

  • 3WL1106-3..34-....

    FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=66KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE

  • 3WL1106-3..36-....

    WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL