3VL3725-1TN43-0AA0 SIEMENS ⍾ 3VL37251TN430AA0
Circuit breaker VL250N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU12, LIG In=250A, rated current IR=100...250A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected with box terminal without auxiliary/alarm switch
- Customs tariff number
- 85362090
- Expected origin
- DE
- Weight
- 3.607 kg
SIEMENS 3VL3725-1TN43-0AA0 Datasheet PDF (en) Size: 242 KB |
Download |
Related in 3vl3725-1t / 3VL3 (200 ... 250 A) ⍾ Page 1
-
3VL3725-1TE46-0AB1
CIRCUIT-BREAKER VL 250N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION ELECTRONIC TRIP UNIT ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5 …
-
3VL3725-1TE46-0AD1
CIRCUIT-BREAKER VL 250N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION ELECTRONIC TRIP UNIT ETU20, LSI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5 …
-
3VL3725-1TF46-0AA0
Circuit breaker VL250N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU20, LSI In=250A, rated current IR=100...250A, overload protectio …
-
3VL3725-1TH46-0AA0
Circuit breaker VL250N Standard switching capacity Icu=55 kA, 415V AC 4-pole, system protection Overcurrent release ETU22, LSIG In=250 A, Rated current Ir=100...250 A, Overload pro …
-
3VL3725-1AA36-0AA0
Circuit breaker VL250N without Electronic Trip Unit standard breaking capacity Icu=55kA/415V AC, 3-pole In=< 250A, rated current with screw terminal connections for switching unit …
-
3VL3725-1AA46-0AA0
Circuit breaker VL250N without Electronic Trip Unit standard breaking capacity Icu=55kA/415V AC, 4-pole In=< 250A, rated current without auxiliary release with screw terminal conne …
-
3VL3725-1AP36-0AB1
CIRCUIT-BREAKER VL 250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, MOTOR/ GENERATOR PROTECTION OVERCURRENT RELEASE ETU10M, LI IN=250A, RATED CURRENT IR=100-250A, OVER …
-
3VL3725-1DC33-0AA0
Circuit breaker VL250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=250A, rated current IR=200...250A, overload protection, I …
-
3VL3725-1DC33-0AB1
Circuit breaker VL250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=250A, rated current IR=200...250A, overload protection, I …
-
3VL3725-1DC33-0AD1
CIRCUIT-BREAKER VL 250N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=250A, RATED CURRENT IR=200-250A, OVERLOAD II=1200-2500 …
-
3VL3725-1DC33-2JD1
Circuit breaker VL250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=250A, rated current IR=200...250A, overload protection, II=1200...25 …
-
3VL3725-1DC36-0AA0
Circuit breaker VL250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=250A, rated current IR=200...250A, overload protection, II=1200...25 …