331-1KF01 Yaskawa ⍾ 3311KF01
331-1KF01 - Signal modules analog | Analog input modules; Order no. : 331-1KF01; Type : SM 331; Features : 8x AI 13 Bit Voltage +/- 10 V, +/- 50 mV, +/- 500 mV, +/- 5 V, 0 V ... +10 V Strom +/- 20 mA, 0/4...20 mA Resistance thermometer For 40 pole front connector; Current consumption from backplane bus : 255 mA; Power loss : 1.3 W; Number of inputs : 8; Cable length, shielded : 50 m; Voltage inputs : Min. input resistance (voltage range) : 100 kΩ; Input voltage ranges : -50 mV ... +50 mV-500 mV ... +500 mV-1 V ... +1 V-5 V ... +5 V0 V ... +10 V-10 V ... +10 V+1 V ... +5 V; Operational limit of voltage ranges : +/-0.5% ... +/-0.6%; Basic error limit voltage ranges : +/-0.3% ... +/-0.4%; Destruction limit voltage : max. 30V; Current inputs : Max. input resistance (current range) : 100 Ω; Input current ranges : -20 mA ... +20 mA0 mA ... +20 mA+4 mA ... +20 mA; Operational limit of current ranges : +/-0.5%; Grundfehlergrenze Strombereiche : +/-0.3%; Destruction limit current inputs (electrical current) : max. 40mA; Destruction limit current inputs (voltage) : max. 15V; Resistance inputs : Resistance ranges : 0 ... 600 Ohm0 ... 6000 Ohm; Operational limit of resistor ranges : +/-0.5%; Basic error limit : +/-0.3%; Destruction limit resistance inputs : max. 15V; Resistance thermometer inputs : Resistance thermometer ranges : Pt100Ni100Ni1000; Operational limit of resistance thermometer ranges : +/-1K ... +/-1.2K; Basic error limit thermoresistor ranges : +/-0.8K; Destruction limit resistance thermometer inputs : max. 15V; Technical unit of temperature measurement : °C, °F, K; Resolution in bit : 13; Measurement principle : Sigma-Delta; Basic conversion time : 61 ms/51 ms / channel; Noise suppression for frequency : 50 Hz/60 Hz; Initial data size : 16 Byte; Status display : none; Interrupts : no; Process alarm : no; Diagnostic interrupt : no; Diagnostic functions : no; Diagnostics information read-out : none; Supply voltage display : none; Group error display : none; Channel error display : none; Between channels and backplane bus : Max. potential difference between inputs (Ucm) : DC 2 V; Max. potential difference between inputs and Mintern (Uiso) : DC 75 V/ AC 50 V; Insulation tested with : DC 500 V; Input bytes : 16; Output bytes : 0; Parameter bytes : 21; Diagnostic bytes : 0; Material : PPE; Mounting : Rail System 300; Dimensions (WxHxD) : 40 mm x 125 mm x 120 mm; Net weight : 260 g; Operating temperature : 0 °C to 60 °C; Storage temperature : -25 °C to 70 °C; UL certification : yes; KC certification : yes