231-1BD53 Yaskawa2311BD53

231-1BD53 - Signal modules analog | Analog input modules; Order no. : 231-1BD53; Type : SM 231; Features : 4x AI 16 Bit Voltage, current Resistance thermometer, thermocouple Parameterizable; Current consumption from backplane bus : 280 mA; Power loss : 1.4 W; Number of inputs : 4; Cable length, shielded : 200 m; Voltage inputs : Min. input resistance (voltage range) : 20 MΩ; Input voltage ranges : -50 mV ... +50 mV-400 mV ... +400 mV-4 V ... +4 V-10 V ... +10 V; Operational limit of voltage ranges : +/-0.3% ... +/-0.6%; Basic error limit voltage ranges : +/-0.2% ... +/-0.4%; Destruction limit voltage : max. 15V; Current inputs : Max. input resistance (current range) : 85 Ω; Input current ranges : -20 mA ... +20 mA0 mA ... +20 mA+4 mA ... +20 mA; Operational limit of current ranges : +/-0.3% ... +/-0.8%; Grundfehlergrenze Strombereiche : +/-0.2% ... +/-0.5%; Destruction limit current inputs (electrical current) : max. 30mA; Resistance inputs : Resistance ranges : 0 ... 60 Ohm0 ... 600 Ohm0 ... 3000 Ohm0 ... 6000 Ohm; Operational limit of resistor ranges : +/-0.4% ... +/-0.8%; Basic error limit : +/-0.2% ... +/-0.4%; Destruction limit resistance inputs : max. 15V; Resistance thermometer inputs : Resistance thermometer ranges : Pt100, Pt1000KTY81-152Ni100, Ni1000Cu50KTY81-110KTY81-120KTY81-121KTY81-122KTY81-150KTY81-151; Operational limit of resistance thermometer ranges : +/-0.4% ... +/-1.4%; Basic error limit thermoresistor ranges : +/-0.2% ... +/-0.7%; Destruction limit resistance thermometer inputs : max. 15V; Thermocouple inputs : Thermocouple ranges : type Jtype Ktype Ntype Rtype Stype Etype T; Operational limit of thermocouple ranges : +/-1.5%; Basic error limit thermoelement ranges : +/-1.0%; Destruction limit thermocouple inputs : max. 15V; Programmable temperature compensation : External temperature compensation : Internal temperature compensation : Temperature error internal compensation : 5 K; Technical unit of temperature measurement : °C; Resolution in bit : 16; Measurement principle : Sigma-Delta; Basic conversion time : 7 ms ... 272 ms; Noise suppression for frequency : none; Initial data size : 8 Byte; Status display : none; Interrupts : yes; Process alarm : no; Diagnostic interrupt : yes, parameterizable; Diagnostic functions : yes; Diagnostics information read-out : possible; Supply voltage display : none; Group error display : none; Channel error display : red LED per channel; Between channels and backplane bus : Max. potential difference between inputs (Ucm) : DC 4 V; Max. potential difference between inputs and Mintern (Uiso) : DC 75 V/ AC 50 V; Insulation tested with : DC 500 V; Input bytes : 8; Output bytes : 0; Parameter bytes : 12; Diagnostic bytes : 12; Material : PPE / PA 6.6; Mounting : Profile rail 35 mm; Dimensions (WxHxD) : 25.4 mm x 76 mm x 88 mm; Net weight : 100 g; Operating temperature : 0 °C to 60 °C; Storage temperature : -25 °C to 70 °C; UL certification : yes