PBSH-RB1X0ST2S0BMA0Z SICK6054503PBSHRB1X0ST2S0BMA0Z

Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 1 bar; Overpressure safety: 2-fold; Process temperature: –20 °C ... +100 °C, +135 °C for max. 1 h; Maximum ohmic load RA: ≤ 0.5 kΩ; Zero point adjustment: Max. + 3 % of span; Output signal: 1 x PNP + 4 mA ... 20 mA; Rotatable housing: Display against housing with electrical connection: 330 °Housing against process connection: 320 °; Display: 14-segment-LED, blue, 4-digits, height 9 mm, electronically turnable by 180°Accuracy: ≤ 1 % of span ± 1 digitUpdate: 1,000, 500, 200, 100 ms (adjustable); EHEDG approval: ✔ 1); Mechanics/electronics: Process connection: Tri-Clamp 2''; Wetted parts: Stainless steel 1.4435 / 316L; Internal transmission fluid: Medical white oil, FDA compliant according to CFR 172.878 and 21 CFR 178.3620(a), compliant to USP, EP, and JP; Housing material: Lower body: stainless steel 304, Plastic head: PC + ABS, Buttons: TPE-E, Display window: PC; Connection type: M12 round connector x 1, 4-pin; Supply voltage: 15 V DC ... 35 V DC; Power consumption: Max. 70 mA; Total current consumption: Max. 320 mA (incl. switching current); Electrical safety: Protection class: IIIOvervoltage protection: 40 V DCShort-circuit protection: QA, Q1, Q2 towards MReverse polarity protection: L+ to M; Isolation voltage: 500 V DC; CE-conformity: EMC directive: 2004/108/EC, EN 61326-2-3; Seal: Without seal; Enclosure rating: IP65 / IP67; Protection class III: ✔; Performance: Non-linearity: ≤ ± 0.5 %, of span (Best Fit Straight Line, BFSL) according to IEC 61298-2; Accuracy: ≤ ± 1 % of the span; Setting accuracy of switching outputs: ≤ ± 0.5 % of span; Response time: 3 ms; Long-term drift/one-year stability : ≤ ± 0.2 % of the span according to IEC 61298-2; Temperature coefficient in rated temperature range: Typical TC of the zero point: in temperature range 0 °C ... 20 °C: 0.7% of the range / 10 K; in temperature range 20 °C ... 80 °C: 0.2% of span / 10 K. Typical TC of span: in temperature range 0 °C ... 80 °C: 0.1% of span / 10 K; Rated temperature range: 0 °C ... +80 °C; Ambient data: Ambient temperature: –20 °C ... +80 °C; Storage temperature: –20 °C ... +80 °C; Relative humidity: 45 % ... 75 %; Shock load: 50 g according to IEC 60068-2-27 (mechanical shock); Vibration load: 10 g according to IEC 60068-2-6 (vibration under resonance); Classifications: ECl@ss 5.0: 27200620; ECl@ss 5.1.4: 27200620; ECl@ss 6.0: 27200620; ECl@ss 6.2: 27200620; ECl@ss 7.0: 27200620; ECl@ss 8.0: 27200620; ECl@ss 8.1: 27200620; ECl@ss 9.0: 27200620; ECl@ss 10.0: 27200620; ECl@ss 11.0: 27200620; ETIM 5.0: EC000243; ETIM 6.0: EC000243; ETIM 7.0: EC000243; UNSPSC 16.0901: 41112409