OY902S ifm ⍾ OYD0810-03-4-06-P-1
Safety light grids; Operating voltage tolerance [%] : 20; Operating voltage [V] : 24 DC; Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : < 10; Type of light : infrared light; Wave length [nm] : 950; Electrical design : PNP; Number of OSSD outputs : 2; Max. current load per OSSD output [mA] : 500; (24 V); Short-circuit protection : yes; Protected area height [mm] : 810; Number of beams : 3; Protection area width (low light intensity) [m] : 0...6; Protection area width (high light intensity) [m] : 0...6; Active/passive system : yes; Response time [ms] : 10.5; Applications : class C to EN 60654-1 weatherproof application; Ambient temperature [°C] : -10...55; Max. relative air humidity [%] : 95; ESPE type (IEC 61496-1) : 4; ISO 13849-1 : category 4, PL e; IEC 61508 : SIL 3; IEC 62061 : SIL cl 3; Mission time TM [h] : 175200; Safety-related reliability PFHD [1/h] : 4.9E-09; Materials : housing: aluminium; front lens: PC; Length L [mm] : 1036; Items supplied : mounting bracket: 6 | slot nuts: 6
- Tipo
- Barreras fotoeléctricas de seguridad
- Conexión
- Connector: 1 x M12; Maximum cable length: 100 m; for wire cross-section 1 mm²
- Número de entradas/salidas
- Number of digital outputs: 2
- Consumo actual
- 250 mA
- Suministro de voltaje
- 24 V
- Mostrar
- transmitter: 4 x LED | transmitter: LC display
- Grado de protección
- IP 65
- Peso
- 7290 g
- Dimensiones
- 1036 x 50 x 60 mm