050-1BA00 Yaskawa0501BA00

050-1BA00 - Function modules | Counter modules; Order no. : 050-1BA00; Type : FM 050; Module ID : 08C1 3800; Features : 1x Counter 32 Bit (AB), DC 24 VUp to 400 kHz1x DO, DC 24 V0,5 A; Current consumption from backplane bus : 75 mA; Power loss : 1 W; Number of inputs : 5; Cable length, shielded : 100 m; Rated load voltage : DC 20.4...28.8 V; Current consumption from load voltage L+ (without load) : 20 mA; Rated value : DC 20.4...28.8 V; Input voltage for signal "0" : DC 0...5 V; Input voltage for signal "1" : DC 15...28.8 V; Signal logic input : Sinking input; Input current for signal "1" : 3 mA; Connection of Two-Wire-BEROs possible : Max. permissible BERO quiescent current : 0.5 mA; Input delay of "0" to "1" : 0.8 µs; Input delay of "1" to "0" : 0.8 µs; Number of simultaneously utilizable inputs horizontal configuration : 5; Number of simultaneously utilizable inputs vertical configuration : 5; Input characteristic curve : IEC 61131-2, type 1; Initial data size : 12 Byte; Number of outputs : 1; Cable length, shielded : 100 m; Cable length, unshielded : 100 m; Rated load voltage : DC 20.4...28.8 V; Output delay of "0" to "1" : 30 µs; Output delay of "1" to "0" : 30 µs; Lamp load : 10 W; Parallel switching of outputs for redundant control of a load : not possible; Parallel switching of outputs for increased power : not possible; Actuation of digital input : Switching frequency with resistive load : max. 10 kHz; Switching frequency with inductive load : max. 0.5 Hz; Switching frequency on lamp load : max. 10 kHz; Internal limitation of inductive shut-off voltage : L+ (-52 V); Short-circuit protection of output : yes, electronic; Trigger level : 1 A; Output data size : 10 Byte; Number of counters : 1; Counter width : 32 Bit; Maximum input frequency : 100 kHz; Maximum count frequency : 400 kHz; Mode incremental encoder : Mode pulse / direction : Gate input available : Latch input available : Reset input available : Counter output available : Status display : yes; Interrupts : yes, parameterizable; Process alarm : yes, parameterizable; Diagnostic interrupt : yes, parameterizable; Diagnostic functions : yes, parameterizable; Diagnostics information read-out : possible; Module state : green LED; Module error display : red LED; Channel error display : none; Between channels and backplane bus : Insulation tested with : DC 500 V; Input bytes : 12; Output bytes : 10; Parameter bytes : 25; Diagnostic bytes : 20; Material : PPE / PPE GF10; Mounting : Profile rail 35 mm; Dimensions (WxHxD) : 12.9 mm x 109 mm x 76.5 mm; Net weight : 57 g; Weight including accessories : 57 g; Gross weight : 71 g; Operating temperature : 0 °C to 60 °C; Storage temperature : -25 °C to 70 °C; UL certification : yes; KC certification : yes