Monitoring Items 97 - 192 de 265 ⍾ Phoenix Contact ⍾ Última modificación
Monitoring ⍾ Página 2
-
-
-
PACT MCR-V2-3015- 60- 60-5A-1
Current transformer - PACT MCR-V2-3015- 60- 60-5A-1 - 2277815; Window-type current transformer, 60 A AC primary current; 5 A AC secondary current; accuracy class 1; 1.25 VA rated p …
-
PACT MCR-V2-3015- 60- 80-5A-1
Current transformer - PACT MCR-V2-3015- 60- 80-5A-1 - 2277831; Window-type current transformer, 80 A AC primary current; 5 A AC secondary current; accuracy class 1; 1.25 VA rated p …
-
PACT MCR-V2-3015- 60- 150-5A-1
Current transformer - PACT MCR-V2-3015- 60- 150-5A-1 - 2277844; Window-type current transformer, 150 A AC primary current; 5 A AC secondary current; accuracy class 1; 3.75 VA rated …
-
PACT MCR-V2-3015- 60- 200-5A-1
Current transformer - PACT MCR-V2-3015- 60- 200-5A-1 - 2277857; Window-type current transformer, 200 A AC primary current; 5 A AC secondary current; accuracy class 1; 7.5 VA rated …
-
PACT MCR-V2-3015- 60- 250-5A-1
Current transformer - PACT MCR-V2-3015- 60- 250-5A-1 - 2277860; Window-type current transformer, 250 A AC primary current; 5 A AC secondary current; accuracy class 1; 7.5 VA rated …
-
PACT MCR-V2-6015- 85- 200-5A-1
Current transformer - PACT MCR-V2-6015- 85- 200-5A-1 - 2277873; Window-type current transformer, 200 A AC primary current; 5 A AC secondary current; accuracy class 1; 2.5 VA rated …
-
PACT MCR-V2-6015- 85- 400-5A-1
Current transformer - PACT MCR-V2-6015- 85- 400-5A-1 - 2277909; Window-type current transformer, 400 A AC primary current; 5 A AC secondary current; accuracy class 1; 2.5 VA rated …
-
PACT MCR-V2-6015- 85- 500-5A-1
Current transformer - PACT MCR-V2-6015- 85- 500-5A-1 - 2277912; Window-type current transformer, 500 A AC primary current; 5 A AC secondary current; accuracy class 1; 5 VA rated po …
-
PACT MCR-V2-6015- 85- 600-5A-1
Current transformer - PACT MCR-V2-6015- 85- 600-5A-1 - 2277925; Window-type current transformer, 600 A AC primary current; 5 A AC secondary current; accuracy class 1; 10 VA rated p …
-
PACT MCR-V2-6015- 85- 750-5A-1
Current transformer - PACT MCR-V2-6015- 85- 750-5A-1 - 2277938; Window-type current transformer, 750 A AC primary current; 5 A AC secondary current; accuracy class 1; 10 VA rated p …
-
PACT MCR-V2-6015- 85- 800-5A-1
Current transformer - PACT MCR-V2-6015- 85- 800-5A-1 - 2277941; Window-type current transformer, 800 A AC primary current; 5 A AC secondary current; accuracy class 1; 10 VA rated p …
-
PACT MCR-V2-6015- 85-1000-5A-1
Current transformer - PACT MCR-V2-6015- 85-1000-5A-1 - 2277954; Window-type current transformer, 1000 A AC primary current; 5 A AC secondary current; accuracy class 1; 15 VA rated …
-
PACT MCR-V2-6015- 85-1250-5A-1
Current transformer - PACT MCR-V2-6015- 85-1250-5A-1 - 2277967; Window-type current transformer, 1250 A AC primary current; 5 A AC secondary current; accuracy class 1; 15 VA rated …
-
-
-
-
-
-
-
-
-
-
-
-
SOL-SC-4ST-0-DC-1MPPT-2000
String combiner box (SCB) - SOL-SC-4ST-0-DC-1MPPT-2000 - 2403334; String combiner box for photovoltaic systems up to 1000 V DC for the connection of 1x 4 strings. With surge protec …
-
SOL-SC-4ST-0-DC-1MPPT-1011
String combiner box (SCB) - SOL-SC-4ST-0-DC-1MPPT-1011 - 2403335; String combiner box for photovoltaic systems up to 1000 V DC for the connection of 1x 4 strings. With surge protec …
-
SOL-SC-1ST-0-DC-3MPPT-2001
String combiner box (SCB) - SOL-SC-1ST-0-DC-3MPPT-2001 - 2403336; String combiner box for photovoltaic systems up to 1000 V DC for the connection of 3x 1 string. With surge protect …
-
SOL-SC-1ST-0-DC-2MPPT-2001
String combiner box (SCB) - SOL-SC-1ST-0-DC-2MPPT-2001 - 2403337; String combiner box for photovoltaic systems up to 1000 V DC for the connection of 2x 1 string. With surge protect …
-
SOL-SC-1ST-0-DC-1MPPT-2001
String combiner box (SCB) - SOL-SC-1ST-0-DC-1MPPT-2001 - 2403338; String combiner box for photovoltaic systems up to 1000 V DC for the connection of 1x 1 string. With surge protect …
-
SOL-SC-2ST-0-DC-2MPPT-1001
String combiner box (SCB) - SOL-SC-2ST-0-DC-2MPPT-1001 - 2404295; String combiner box for photovoltaic systems up to 1000 V DC for the connection of 2x 2 strings. With surge protec …
-
SOL-SC-4ST-0-DC-1MPPT-1001
String combiner box (SCB) - SOL-SC-4ST-0-DC-1MPPT-1001 - 2404296; String combiner box for photovoltaic systems up to 1000 V DC for the connection of 1x 4 strings. With surge protec …
-
SOL-SC-2ST-0-DC-1MPPT-1101
String combiner box (SCB) - SOL-SC-2ST-0-DC-1MPPT-1101 - 2404297; String combiner box for photovoltaic systems up to 1000 V DC for the connection of 1x 2 strings. With surge protec …
-
SOL-SC-1ST-0-DC-1MPPT-1001
String combiner box (SCB) - SOL-SC-1ST-0-DC-1MPPT-1001 - 2404298; String combiner box for photovoltaic systems up to 1000 V DC for the connection of 1x 1 string. With surge protect …
-
SOL-SC-1ST-0-DC-2MPPT-1001
String combiner box (SCB) - SOL-SC-1ST-0-DC-2MPPT-1001 - 2404299; String combiner box for photovoltaic systems up to 1000 V DC for the connection of 2x 1 string. With surge protect …
-
SOL-SC-1ST-0-DC-3MPPT-1001
String combiner box (SCB) - SOL-SC-1ST-0-DC-3MPPT-1001 - 2404301; String combiner box for photovoltaic systems up to 1000 V DC for the connection of 3x 1 string. With surge protect …
-
SOL-SC-2ST-0-DC-2MPPT-1101
String combiner box (SCB) - SOL-SC-2ST-0-DC-2MPPT-1101 - 2404569; String combiner box for photovoltaic systems up to 1000 V DC for the connection of 2x 2 strings. With surge protec …
-
SOL-SC-3ST-0-DC-1MPPT-1001
String combiner box (SCB) - SOL-SC-3ST-0-DC-1MPPT-1001 - 2404765; String combiner box for photovoltaic systems up to 1000 V DC for the connection of 1x 3 strings. With surge protec …
-
SOL-SC-1ST-0-DC-4MPPT-1000SE
String combiner box (SCB) - SOL-SC-1ST-0-DC-4MPPT-1000SE - 2404842; String combiner box for photovoltaic systems up to 1000 V DC for the connection of 4x 1 string. With surge prote …
-
SOL-SC-1ST-0-DC-6MPPT-1000SE
String combiner box (SCB) - SOL-SC-1ST-0-DC-6MPPT-1000SE - 2404843; String combiner box for photovoltaic systems up to 1000 V DC for the connection of 6x 1 string. With surge prote …
-
LM-S-LS-H
Lightning current measuring system - LM-S-LS-H - 2800616; Optical lightning sensor for the live monitoring system for the continuous detection and evaluation of lightning strikes. …
-
-
LM-S-A/C-3S-ETH
Lightning current measuring system - LM-S-A/C-3S-ETH - 2800618; Evaluation unit for the live monitoring system for the continuous detection and evaluation of lightning strikes. Up …
-
MACX MCR-SL-CAC- 5-I
Current transducers - MACX MCR-SL-CAC- 5-I - 2810612; Current measuring transducer for 1 A and 5 A AC, the output signal 0...20 mA or 4...20 mA, can be configured using a DIP switc …
-
MACX MCR-SL-CAC- 5-I-UP
Transductor de medición de corriente para 1 A y 5 A AC, señal de salida 0...20 mA o 4...20 mA, configurable mediante un interruptor DIP con indicación del modo de operación mediant …
-
MACX MCR-SL-CAC-12-I-UP
Current transducers - MACX MCR-SL-CAC-12-I-UP - 2810638; Current measuring transducer for 5 A and 12 A AC, the output signal 0...20 mA or 4...20 mA, can be configured using a DIP s …
-
MCR-VAC-UI-O-DC
Voltage measuring transducers - MCR-VAC-UI-O-DC - 2811103; MCR voltage measuring transducer, for alternating current voltages from 0..20 V AC to 0..440 V AC, output signal 0..10 V/ …
-
MCR-SL-S-100-U
Current transducers - MCR-SL-S-100-U - 2813457; MCR current measuring transducer, for measuring sinusoidal and non-sinusoidal alternating currents, input current 0...100 A, output …
-
MCR-SL-S-200-U
Current transducers - MCR-SL-S-200-U - 2813460; MCR current measuring transducer, for measuring sinusoidal and non-sinusoidal alternating currents, input current 0...200 A, output …
-
MCR-SL-S-400-U
Current transducers - MCR-SL-S-400-U - 2813473; MCR current measuring transducer, for measuring sinusoidal and non-sinusoidal alternating currents, input current 0...400 A, output …
-
-
MCR-SL-S-200-I-LP
Current transducers - MCR-SL-S-200-I-LP - 2813499; MCR current measuring transducer, for measuring sinusoidal and non-sinusoidal alternating currents, input current 0...200 A, loop …
-
-
-
-
-
MCR-S-1-5-UI-DCI
Transformador de corriente MCR, programable y configurable, para la medición de corrientes continuas, alternas y distorsionadas, corriente de entrada de 0 ... 0,2 A a 0 ... 11 A, c …
-
MCR-S-1-5-UI-SW-DCI
Transformador de corriente MCR, programable y configurable, para la medición de corrientes continuas, alternas y distorsionadas, con salida de relé y transistor, corriente de entra …
-
MCR-S-1-5-UI-DCI-NC
Transformador de corriente MCR, programable y configurable, para la medición de corrientes continuas, alternas y distorsionadas, corriente de entrada 0...0.2 a 0...11 A, no configu …
-
MCR-S10-50-UI-DCI-NC
Current transducers - MCR-S10/50-UI-DCI-NC - 2814728; MCR current measuring transducer, programmable and configurable, for measuring direct, alternating and distorted currents, inp …
-
MCR-S-1-5-UI-SW-DCI-NC
Current transducers - MCR-S-1/5-UI-SW-DCI-NC - 2814731; MCR current transducer, programmable and configurable, for measuring direct, alternating and distorted currents, with relay …
-
MCR-S10-50-UI-SW-DCI-NC
Current transducers - MCR-S10/50-UI-SW-DCI-NC - 2814744; MCR current measuring transducer, programmable and configurable, for measuring direct, alternating and distorted currents, …
-
-
EMD-SL-C-OC-10
Relé de supervisión para la monitorización de corrientes de alterna/continua de 0…10 A AC/DC, protección contra sobrecorriente, voltaje de alimentación seleccionable a través de mó …
-
-
EMD-SL-V-UV-300
Relé de monitorización para la supervisión de voltajes monofásicos de 0…300 V AC/DC, detección de subtensión, voltaje de alimentación seleccionable mediante módulo de alimentación, …
-
EMD-FL-V-300
Relé de monitorización para la supervisión de voltajes monofásicos de 0…300 V AC/DC, sobretensión/subtensión o ventana, memoria de errores, amplia fuente de alimentación, 2 contact …
-
EMD-SL-3V-400
Monitoring relay - EMD-SL-3V-400 - 2866051; Monitoring relay for monitoring 3-phase voltages of 280...520 V AC, window, without neutral conductor connection, supply voltage can be …
-
EMD-FL-3V-400
Relé de monitorización para la supervisión de voltajes trifásicos de 280…520 V AC, subtensión, ventana, secuencia de fase, fallo de fase, asimetría, fuente de alimentación de ampli …
-
-
EMD-SL-PTC
Relé de supervisión para el control de temperatura del devanado del motor (máximo 6 PTC), con memoria de errores para sensores de temperatura según DIN 44081, función de prueba con …
-
-
-
-
EMD-SL-C-UC-10
Monitoring relay - EMD-SL-C-UC-10 - 2867937; Monitoring relay for monitoring 1-phase currents of 0...10 A AC/DC, undercurrent, supply voltage can be selected using power module, 1 …
-
EMD-FL-3V-500
Relé de monitoreo para el monitoreo de voltajes trifásicos de 350…650 V AC, subtensión, ventana, secuencia de fase, falla de fase, asimetría, voltaje de alimentación seleccionable …
-
EMD-FL-3V-690
Monitoring relay - EMD-FL-3V-690 - 2885249; Monitoring relay for monitoring 3-phase voltages of 483...897 V AC, undervoltage, window, phase sequence, phase failure, asymmetry, supp …
-
EMD-SL-3V-400-N
Monitoring relay - EMD-SL-3V-400-N - 2885278; Monitoring relay for monitoring 3-phase voltages of 280...520 V AC, window, with neutral conductor connection, supply voltage can be s …
-
-
-
-
-
-
EMD-FL-3V-230
Monitoring relay - EMD-FL-3V-230 - 2885773; Monitoring relay for monitoring 3-phase voltages of 160 ... 300 V AC, undervoltage, window, phase sequence, phase failure, asymmetry, wi …
-
EMD-FL-PF-400
Monitoring relay - EMD-FL-PF-400 - 2885809; Monitoring relay for load monitoring (cos ϕ = 0,1 ... 1) in 1- and 3-phase networks, underload, overload, window, error memory, wide-ran …
-
-
EMD-FL-RP-480
Monitoring relay - EMD-FL-RP-480 - 2900177; Monitoring relay for effective power monitoring in 1- and 3-phase networks of 0...7.2 kW, underload, overload, window, motor winding tem …
-
-
-
-
-
PACT RCP-4000A-1A
Este es un producto individual; por favor, ordene el conjunto completo. El transductor de medición procesa la señal de mV de la bobina de Rogowski anterior. El transductor de medic …
-
SCK-M-I-8S-20A
PV string monitoring module - SCK-M-I-8S-20A - 2903241; SCK measuring module for monitoring photovoltaic systems, 8 x current measurement up to 20 A, 1 x digital input, interface t …
-
SCK-M-I-4S-20A
PV string monitoring module - SCK-M-I-4S-20A - 2903242; SCK measuring module for monitoring photovoltaic systems, 4 x current measurement up to 20 A, 1 x digital input, interface t …
-
EMD-BL-C-10
Monitoring relay - EMD-BL-C-10 - 2903521; Monitoring relay for monitoring single-phase currents of 0 ... 5 A AC or 0 ... 10 A AC, overcurrent/undercurrent or window, 1 PDT, with sc …