Fibre optic sensor Items 1 - 39 de 39 ⍾ Turck ⍾ Última modificación
Fibre optic sensor ⍾ Página 1
-
D12DAB6FP
Photoelectric sensor, base unit for optical fibers. Base unit for optical fiber. Dynamic sensor. Device for DIN rail mounting. 7-segment LED chain indicates received light quantity …
-
D12DAB6FPQ
Photoelectric sensor, base unit for optical fibers. Base unit for optical fiber. Dynamic sensor. Device for DIN rail mounting. 7-segment LED chain indicates received light quantity …
-
D12DAB6FV
Photoelectric sensor, base unit for optical fibers. Base unit for optical fiber. Dynamic sensor. Device for DIN rail mounting. 7-segment LED chain indicates received light quantity …
-
D12DAB6FVQ
Photoelectric sensor, base unit for optical fibers. Base unit for optical fiber. Dynamic sensor. Device for DIN rail mounting. 7-segment LED chain indicates received light quantity …
-
D12EP6FP
Photoelectric sensor, base unit for optical fibers. Base unit for plastic fibers. 7-segment LED chain for indication of excess gain. connection cable, 2 m. Operating voltage 10...3 …
-
D12EP6FV
Photoelectric sensor, base unit for optical fibers. Base unit for glass fibers. 7-segment LED chain for indication of excess gain. connection cable, 2 m. Operating voltage 10...30 …
-
D12SP6FP
Photoelectric sensor, base unit for optical fibers. Base unit for plastic fibers. 7-segment LED chain for indication of excess gain. connection cable, 2 m. Operating voltage 10...3 …
-
D12SP6FPH
Photoelectric sensor, base unit for optical fibers. Base unit for plastic fibers. 7-segment LED chain for indication of excess gain. connection cable, 2 m. Operating voltage 10...3 …
-
D12SP6FPHQ
Photoelectric sensor, base unit for optical fibers. Base unit for plastic fibers. 7-segment LED chain for indication of excess gain. connector 8 mm. Operating voltage 10...30 VDC. …
-
D12SP6FPQ
Photoelectric sensor, base unit for optical fibers. Base unit for plastic fibers. 7-segment LED chain for indication of excess gain. connector 8 mm. Operating voltage 10...30 VDC. …
-
D12SP6FPY
Photoelectric sensor, base unit for optical fibers. Base unit for plastic fibers. 7-segment LED chain for indication of excess gain. connection cable, 2 m. Operating voltage 10...3 …
-
D12SP6FPY1
Photoelectric sensor, base unit for optical fibers. Base unit for plastic fibers. 7-segment LED chain for indication of excess gain. connection cable, 2 m. Operating voltage 10...3 …
-
D12SP6FPY1Q
Photoelectric sensor, base unit for optical fibers. Base unit for plastic fibers. 7-segment LED chain for indication of excess gain. connector 8 mm. Operating voltage 10...30 VDC. …
-
D12SP6FPYQ
Photoelectric sensor, base unit for optical fibers. Base unit for plastic fibers. 7-segment LED chain for indication of excess gain. connector 8 mm. Operating voltage 10...30 VDC. …
-
D12SP6FV
Photoelectric sensor, base unit for optical fibers. Base unit for glass fibers. 7-segment LED chain for indication of excess gain. connection cable, 2 m. Operating voltage 10...30 …
-
D12SP6FVQ
Photoelectric sensor, base unit for optical fibers. Base unit for glass fibers. 7-segment LED chain for indication of excess gain. connector 8 mm. Operating voltage 10...30 VDC. PN …
-
D12SP6FVY
Photoelectric sensor, base unit for optical fibers. Base unit for glass fibers. 7-segment LED chain for indication of excess gain. connection cable, 2 m. Operating voltage 10...30 …
-
D12SP6FVY1
Photoelectric sensor, base unit for optical fibers. Base unit for glass fibers. 7-segment LED chain for indication of excess gain. connection cable, 2 m. Operating voltage 10...30 …
-
D12SP6FVY1Q
Photoelectric sensor, base unit for optical fibers. Base unit for glass fibers. 7-segment LED chain for indication of excess gain. connector 8 mm. Operating voltage 10...30 VDC. PN …
-
D12SP6FVYQ
Photoelectric sensor, base unit for optical fibers. Base unit for glass fibers. 7-segment LED chain for indication of excess gain. connector 8 mm. Operating voltage 10...30 VDC. PN …
-
-
-
MIAD9F
Photoelectric sensor, base unit for glass fibers. ATEX II 1 G approval. Acc. to EN 60947-5-6 (NAMUR). Cable, PVC, 2 m. Protection class IP67. Sensitivity adjusted via potentiometer …
-
MIAD9FQ
Photoelectric sensor, base unit for glass fibers. ATEX II 1 G approval. Acc. to EN 60947-5-6 (NAMUR). Metallic optical fibers must be grounded. Male M12 x 1, 4-pin. Protection clas …
-
Q45AD9F
Photoelectric sensor, base unit for glass fibers. ATEX category II 1 G, Ex zone 0. Cable, PVC, 2 m. Protection class IP67. Sensitivity adjusted via potentiometer. Operating voltage …
-
Q45AD9FP
Photoelectric sensor, base unit for optical fibers. ATEX category II 1 G, Ex zone 0. Cable, PVC, 2 m. Protection class IP67. Sensitivity adjusted via potentiometer. Operating volta …
-
Q45AD9FPQ
Photoelectric sensor, base unit for optical fibers. ATEX category II 1 G, Ex zone 0. Male M12 x 1. Protection class IP67. Sensitivity adjusted via potentiometer. Operating voltage: …
-
Q45AD9FQ
Photoelectric sensor, base unit for glass fibers. ATEX category II 1 G, Ex zone 0. Male M12 x 1. Protection class IP67. Sensitivity adjusted via potentiometer. Operating voltage: 5 …
-
Q45BB6F
Photoelectric sensor, base unit for glass fibers. Cable, PVC, 2 m. Protection class IP67. Connecting cable, 2 m. Operating voltage: 10...30 VDC. Switching output, bipolar. Light or …
-
Q45BB6FP
Photoelectric sensor, base unit for optical fibers. Base unit for optical fiber. Rectangular plastic housing, lateral light emission. High excess gain. Sensitivity adjusted via pot …
-
Q45BB6FPQ5
Photoelectric sensor, base unit for optical fibers. Male M12 x 1. Protection class IP67. Male connector,. Operating voltage: 10...30 VDC. Switching output, bipolar. Light or dark o …
-
Q45BB6FQ5
Photoelectric sensor, base unit for glass fibers. Male M12 x 1. Protection class IP67. Sensitivity adjusted via potentiometer. Operating voltage: 10...30 VDC. Switching output, bip …
-
QM42VN6FP
Photoelectric sensor, base unit for plastic fibers. Cable, PVC, 2 m, 4-wire. Metal housing, ZN, black. Protection class IP67. Sensitivity adjusted via potentiometer. Operating volt …
-
QM42VN6FPQ
Photoelectric sensor, base unit for plastic fibers. Male M12 x 1, 4-pin. Metal housing, ZN, black. Protection class IP67. Sensitivity adjusted via potentiometer. Operating voltage …
-
QM42VP6FP
Photoelectric sensor, base unit for plastic fibers. Cable, PVC, 2 m, 4-wire. Metal housing, ZN, black. Protection class IP67. Sensitivity adjusted via potentiometer. Operating volt …
-
QM42VP6FPQ
Photoelectric sensor, base unit for plastic fibers. Male M12 x 1, 4-pin. Metal housing, ZN, black. Protection class IP67. Sensitivity adjusted via potentiometer. Operating voltage …
-
-
-
SME312FQD
Photoelectric sensor, base unit for glass fibers. Male M12 x 1, 5-pin. Protection class IP67. Teach-in function. Operating voltage: 10...30 VDC. Switching output, bipolar. Light/da …