7SA5221-5PB90-4HA4 L0S
AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) PORT B: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET WITH INTE …
-
-
-
-
7SA5221-6AB90-0CA4 L0R
AUXIL. VOLTAGE:220V TO 250V DC, 115V AC, BINARY INPUT THRESHOLD 176V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) PORT P: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET ELECTRIC …
-
7SA5221-6CB90-0FA4 L0S
AUXIL. VOLTAGE:220V TO 250V DC, 115V AC, BINARY INPUT THRESHOLD 176V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) PORT B: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET WITH INT …
-
7SA5221-6CB90-0NB4 L0S
AUXIL. VOLTAGE:220V TO 250V DC, 115V AC, BINARY INPUT THRESHOLD 176V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) PORT B: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET WITH INT …
-
7SA5221-6UA01-5NR5
AUXIL. VOLTAGE:220V TO 250V DC, 115V AC, BINARY INPUT THRESHOLD 176V REGION DE, LANGUAGE GERMAN (LANGUAGE SELECTABLE) WITHOUT SYSTEM INTERFACE DIGSI/MODEM OPERATING INTERFACE (ON R …
-
7SA5222-5AB22-0HQ4
AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) SYSTEM INTERFACE: IEC 60870-5-103,ELECTRIC. RS485 DIGSI/MO …
-
-
7SA5225-4CB92-4QR4 L0R
AUXIL. VOLTAGE: 60V TO 125V DC BINARY INPUT THRESHOLD 19V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) PORT P: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET ELECTRICAL,DOUBLE,R …
-
7SA5225-5AB92-0HN4 L0R
AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) PORT P: SYSTEM PORT, IEC 61850,100 MBIT ETHERNET ELECTRICA …
-
7SA5225-5AB92-0QM4 L0G
AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) PORT B: SYSTEM PORT, DNP3.0, ELECTRIC RS485 DIGSI/MODEM OP …
-
7SA5225-5CB00-0QP4
AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) WITHOUT SYSTEM INTERFACE NO 2ND OPERATING INTERFACE FUNCTI …
-
7SA5225-5DB20-4NM4
FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER:PHASE = 5A, GROUND(EARTH)= 5A (MIN=0,25A) FLUSH-MOUNTG. HOUSING 1/1 X 19" 24 BI, 32 BO AUXIL. VOLTAGE: 110V TO 250V DC 11 …
-
-
7SA5225-6AB92-1FA4
+L0R FULL SCHEME DISTANCE PROTECTION RELAY, CURRENT TRANSFORMER:PHASE = 5A, GROUND(EARTH)= 5A (MIN=0,25A) FLUSH-MOUNTG. HOUSING 1/2 X 19" 8 BI, 16 BO AUXIL. VOLTAGE:220V TO 250V DC, 115 …
-
7SA5225-6DB02-0QP4
AUXIL. VOLTAGE:220V TO 250V DC, 115V AC, BINARY INPUT THRESHOLD 176V REGION WORLD,LANGUA. UK-ENGLISH (LANGUAGE SELECTABLE) WITHOUT SYSTEM INTERFACE DIGSI/MODEM OPERATING INTERFACE …
-
-
-
7SA6105-5AB31-0CB0
Distance protection 7SA61 operating front with 4-line illuminated display, function keys, numeric operator panel, PC interface MEASURING INPUT (4 X V, 4 XI) IPH = 5A, IE = 5A (MIN …
-
7SA6111-4AB91-0PP4 L0S
MEASURING INPUT (4 X V, 4 X I) IPH = 1A, IE = 1A (MIN = 0.05A) AUXILIARY VOLTAGE: 60 TO 125V DC, BINARY INPUT THRESHOLD 19V HOUSING WIDTH 1/2 19", 14 LEDS 13 BINARY/INDICATION INPU …
-
7SA6111-4AB92-0PQ4 L0R
MEASURING INPUT (4 X V, 4 X I) IPH = 1A, IE = 1A (MIN = 0.05A) AUXILIARY VOLTAGE: 60 TO 125V DC, BINARY INPUT THRESHOLD 19V HOUSING WIDTH 1/2 19", 14 LEDS 13 BINARY/INDICATION INPU …
-
7SA6111-4AB99-1GN0 L0S
+M2G MEASURING INPUT (4 X V, 4 X I) IPH = 1A, IE = 1A (MIN = 0.05A) AUXILIARY VOLTAGE: 60 TO 125V DC, BINARY INPUT THRESHOLD 19V HOUSING WIDTH 1/2 19", 14 LEDS 13 BINARY/INDICATION INPU …
-
-
7SA6111-5AB91-7PR4 L0A
DISTANCE PROTECTION RELAY 7SA61 OPERATOR PANEL WITH: 4-LINE BACK-LIT DISPLAY, FUNCTION KEYS,NUMERICAL KEYS, PC-INTERFACE, TRIPPING 3-POLE TRIPPING 1/3-POLE PICKUP I>, PICKUP V/ PIC …
-
7SA6111-5AB92-0GK0 L0S
MEASURING INPUT (4 X V, 4 X I) IPH = 1A, IE = 1A (MIN = 0.05A) AUXILIARY VOLTAGE: 110 TO 250V DC, 115 TO 230V AC, BINARY INPUT THRESHOLD 88V HOUSING WIDTH 1/2 19", 14 LEDS 13 BINAR …
-
7SA6111-5AB92-0PN4 L0S
MEASURING INPUT (4 X V, 4 X I) IPH = 1A, IE = 1A (MIN = 0.05A) AUXILIARY VOLTAGE: 110 TO 250V DC, 115 TO 230V AC, BINARY INPUT THRESHOLD 88V HOUSING WIDTH 1/2 19", 14 LEDS 13 BINAR …
-
7SA6115-4AE22-0GJ0
MEASURING INPUT (4 X V, 4 XI) IPH = 5A, IE = 5A (MIN = 0.25A) AUXILIARY VOLTAGE: 60 TO 125V DC, BINARY INPUT THRESHOLD 19V HOUSING WIDTH 1/2 19", 14 LEDS 13 BINARY/INDICATION INPUT …
-
7SA6115-5AB22-0PK4
DISTANCE PROTECTION RELAY 7SA61 OPERATOR PANEL WITH: 4-LINE BACK-LIT DISPLAY, FUNCTION KEYS,NUMERICAL KEYS, PC-INTERFACE, EARTH-FAULT PROT. DIRECTIONAL, EARTHED NETWORKS MEASURING …
-
7SA6115-5AE92-0DB4 L0R
MEASURING INPUT (4 X V, 4 XI) IPH = 5A, IE = 5A (MIN = 0.25A) AUXILIARY VOLTAGE: 110 TO 250V DC, 115 TO 230V AC, BINARY INPUT THRESHOLD 88V HOUSING WIDTH 1/2 19", 14 LEDS 13 BINARY …
-
7SA6115-5BB22-0DC0
DISTANCE PROTECTION RELAY 7SA61 OPERATOR PANEL WITH: 4-LINE BACK-LIT DISPLAY, FUNCTION KEYS,NUMERICAL KEYS, PC-INTERFACE, MEASURING INPUT (4 X V, 4 XI) IPH = 5A, IE = 5A (MIN = 0.2 …
-
7SA6115-5BB92-7PR4 L0S
DISTANCE PROTECTION RELAY 7SA61 OPERATOR PANEL WITH: 4-LINE BACK-LIT DISPLAY, FUNCTION KEYS,NUMERICAL KEYS, PC-INTERFACE, TRIPPING 3-POLE TRIPPING 1/3-POLE PICKUP I>, PICKUP V/ PIC …
-
7SA6121-4AB02-5GQ0
MEASURING INPUT (4 X V, 4 X I) IPH = 1A, IE = 1A (MIN = 0.05A) AUXILIARY VOLTAGE: 60 TO 125V DC, BINARY INPUT THRESHOLD 19V HOUSING WIDTH 1/1 19", 14 LEDS 21 BINARY/INDICATION INPU …
-
-
-
7SA6121-4MB21-1PR4
MEASURING INPUT (4 X V, 4 X I) IPH = 1A, IE = 1A (MIN = 0.05A) AUXILIARY VOLTAGE: 60 TO 125V DC, BINARY INPUT THRESHOLD 19V HOUSING WIDTH 1/1 19", 14 LEDS 21 BINARY/INDICATION INPU …
-
7SA6121-5AB99-0PP4 L0R
+M2G DISTANCE PROTECTION RELAY 7SA61 OPERATOR PANEL WITH: 4-LINE BACK-LIT DISPLAY, FUNCTION KEYS,NUMERICAL KEYS, PC-INTERFACE, EARTH-FAULT PROT. DIRECTIONAL, EARTHED NETWORKS MEASURING …
-
7SA6121-5BE92-7PR4 L0S
MEASURING INPUT (4 X V, 4 X I) IPH = 1A, IE = 1A (MIN = 0.05A) AUXILIARY VOLTAGE: 110 TO 250V DC, 115 TO 230V AC, BINARY INPUT THRESHOLD 88V HOUSING WIDTH 1/1 19", 14 LEDS 29 BINAR …
-
7SA6121-5MB91-5FR4 L0R
MEASURING INPUT (4 X V, 4 X I) IPH = 1A, IE = 1A (MIN = 0.05A) AUXILIARY VOLTAGE: 110 TO 250V DC, 115 TO 230V AC, BINARY INPUT THRESHOLD 88V HOUSING WIDTH 1/1 19", 14 LEDS 21 BINAR …
-
-
7SA613
Distance protection relay for all voltage levels, Housing width 1/1 19", 14 LEDs.; The SIPROTEC 7SA6 distance protection relay is a universal relay for protection, control and auto …
-
7SA6131-2AB91-7PR4 L0R
MEASURING INPUT (4 X V, 4 X I) IPH = 1A, IE = 1A (MIN = 0.05A) AUXILIARY VOLTAGE: 24 TO 48V DC, BINARY INPUT THRESHOLD 19V HOUSING WIDTH 2/3 19", 21 BINARY/INDICATION INPUTS, 13 SI …
-
7SA6131-2AB91-7PR4
+L0R MEASURING INPUT (4 X V, 4 X I) IPH = 1A, IE = 1A (MIN = 0.05A) AUXILIARY VOLTAGE: 24 TO 48V DC, BINARY INPUT THRESHOLD 19V HOUSING WIDTH 2/3 19", 21 BINARY/INDICATION INPUTS, 13 SI …
-
7SA63
Distance protection relay for all voltage levels.; The SIPROTEC 7SA6 distance protection relay is a universal relay for protection, control and automation. The SIPROTEC 7SA63 is eq …
-
7SA6311-5AB91-5FB4 L0S
MEASURING INPUT (4 X V, 4 X I) IPH = 1A, IE = 1A (MIN = 0.05A) AUXILIARY VOLTAGE: 110 TO 250V DC, 115 TO 230V AC, BINARY INPUT THRESHOLD 88V HOUSING WIDTH 1/2 19", 14 LEDS 13 BINAR …
-
7SA6315-5AB92-4CP4 L0R
MEASURING INPUT (4 X V, 4 XI) IPH = 5A, IE = 5A (MIN = 0.25A) AUXILIARY VOLTAGE: 110 TO 250V DC, 115 TO 230V AC, BINARY INPUT THRESHOLD 88V HOUSING WIDTH 1/2 19", 14 LEDS 13 BINARY …
-
7SA64
Distance protection relay for all voltage levels.; The SIPROTEC 7SA6 distance protection relay is a universal relay for protection, control and automation. The SIPROTEC 7 SA64 is e …
-
7SA84 - Distance Protection
Distance protection, 3-pole, min. tripping time 25 ms, 4 current transformers, 4 voltage transform-ers, 5 binary inputs, 8 binary outputs (1 standard, 7 fast relays). The I/O quant …
-
7SA86 - Distance Protection
Distance Protection, 3-pole, min. tripping time 15 ms, 12 predefined standard variants with 4/4 or 8/8 current/voltage transformers, 5 to 31 binary inputs, 8 to 46 binary outputs o …
-
7SA87 - Distance Protection
Distance Protection, 1- and 3-pole, min. tripping time 15 ms, 12 predefined standard variations with 4/4 or 8/8 current/voltage transformers, 5 to 31 binary inputs, 8 to 46 binary …
-
-
-
-
7SD5221-4AB29-0CK0 M0B
MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 60V TO 125V DC BINARY INPUT THRESHOLD 19V FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/2 X 19", 8 BI, 15 BO, 1 LIVE-STATUS CON …
-
7SD5221-4AB29-4FJ0 M0A
MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 60V TO 125V DC BINARY INPUT THRESHOLD 19V FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/2 X 19", 8 BI, 15 BO, 1 LIVE-STATUS CON …
-
7SD5221-4AB39-9EJ1 M2H
+N0H MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 60V TO 125V DC BINARY INPUT THRESHOLD 19V FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/2 X 19", 8 BI, 15 BO, 1 LIVE-STATUS CON …
-
-
-
-
7SD5221-4CB99-4CJ0 L0A
+M1A MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 60V TO 125V DC BINARY INPUT THRESHOLD 19V FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/1 X 19", 16 BI, 23 BO, 1 LIVE-STATUS CO …
-
7SD5221-4CB99-4CJ0 L0S
+M0A MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 60V TO 125V DC BINARY INPUT THRESHOLD 19V FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/1 X 19", 16 BI, 23 BO, 1 LIVE-STATUS CO …
-
-
7SD5221-4DB29-3BN0 M2A
MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 60V TO 125V DC BINARY INPUT THRESHOLD 19V FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/1 X 19", 24 BI, 31 BO, 1 LIVE-STATUS CO …
-
-
7SD5221-4NB99-9HJ0 L0R
+M2G +N1G MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 60V TO 125V DC BINARY INPUT THRESHOLD 19V WITH 5 FAST TRIP CONTACTS, APPROX. 1MS, FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1 …
-
-
7SD5221-5AB99-0HK4 L0S
+M0A MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/2 X 19", 8 BI, 15 BO, 1 LIVE- …
-
7SD5221-5AB99-9EL4
+M2G +N0G +L0S TWO TERMINAL DIFFERENT. RELAY; WITH 4-LINE DISPLAY; MEASUREMENT INPUT: IPH = 1A; IE = 1A; AUXIL. VOLTAGE: 110V TO 250V DC; 115V AC,; BINARY INPUT THRESHOLD 88V; FLUSH-MOUNTING HOUS …
-
-
-
7SD5221-5CB29-0GK0 M0A
MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/1 X 19", 16 BI, 23 BO, 1 LIVE …
-
-
7SD5221-5CB99-9HL4 L0S
+M0G +N0G MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/1 X 19", 16 BI, 23 BO, 1 LIVE …
-
7SD5221-5DB99-7HK1 L0S
+M2G MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/1 X 19", 24 BI, 31 BO, 1 LIVE …
-
7SD5221-5NB99-7HJ4 L0S
+M0H MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V WITH 5 FAST TRIP CONTACTS, APPROX. 1MS, FLUSH-MOUNTING HOUSING WITH SCREW T …
-
-
7SD5221-5NB99-9GM7 L0S
+M2A +N7A MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V WITH 5 FAST TRIP CONTACTS, APPROX. 1MS, FLUSH-MOUNTING HOUSING WITH SCREW T …
-
-
-
7SD5221-5PB99-9HL5 L0S
+M2A +N2A MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V WITH 5 FAST TRIP CONTACTS, APPROX. 1MS, FLUSH-MOUNTING HOUSING WITH SCREW T …
-
7SD5221-5PB99-9HL5 L0S
+M2A +N7A MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V WITH 5 FAST TRIP CONTACTS, APPROX. 1MS, FLUSH-MOUNTING HOUSING WITH SCREW T …
-
7SD5221-5PB99-9HM4 L0S
+M0A +N0A MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V WITH 5 FAST TRIP CONTACTS, APPROX. 1MS, FLUSH-MOUNTING HOUSING WITH SCREW T …
-
7SD5221-5PB99-9HM4 L0S
+M0S +N2S MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V WITH 5 FAST TRIP CONTACTS, APPROX. 1MS, FLUSH-MOUNTING HOUSING WITH SCREW T …
-
-
7SD5221-5PB99-9HV7 L0S
+M2J +N7A MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V WITH 5 FAST TRIP CONTACTS, APPROX. 1MS, FLUSH-MOUNTING HOUSING WITH SCREW T …
-
7SD5221-5PB99-9HV7 L0S
+M3A +N7J MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V WITH 5 FAST TRIP CONTACTS, APPROX. 1MS, FLUSH-MOUNTING HOUSING WITH SCREW T …
-
-
-
7SD5221-6AB99-9HL1
+L0R +M0G +N0G TWO TERMINAL DIFFERENT. RELAY WITH 4-LINE DISPLAY MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 220V TO 250V DC 115V AC,BINARY INPUT THRESHOLD 176V FLUSH-MOUNTING HOUSING WI …
-
7SD5221-6CB99-9HL4 L0S
+M0A +N2G MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 220V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 176V FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/1 X 19", 16 BI, 23 BO, 1 LIV …
-
7SD5221-6NB29-9HJ4 M2H
+N2H MEASUREMENT INPUT: IPH = 1A; IE = 1A AUXIL. VOLTAGE: 220V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 176V WITH 5 FAST TRIP CONTACTS, APPROX. 1MS, FLUSH-MOUNTING HOUSING WITH SCREW …
-
-
7SD5222-5CB99-9HA5 L0S
+M0A +N0A MEASUREMENT INPUT: IPH = 1A, IE = SENSITIVE (MIN. = 0.003A) AUXIL. VOLTAGE: 110V TO 250V DC 115V AC, BINARY INPUT THRESHOLD 88V FLUSH-MOUNTING HOUSING WITH SCREW TERMINALS 1/1 X 19 …
-
7SD5225-2AB99-9CJ0 L0S