INT TECHNICS Industrial Automation Partner
  • Sobre nosotros
  • Seleccione brand
    ABB BANNER Baumer BECKHOFF Danfoss ifm INNOMOTICS Keyence Murrelektronik OBO Omron Pepperl+Fuchs Phoenix Contact PILZ Schneider Electric SICK SIEMENS Telemecanique Turck Weidmüller WEINTEK Yaskawa
  • Contacto
  • Español Es Español
    English Deutsch Español Polski
  • Añadir a SDC Solicitud de Cotización
  1. Catalogar
  2. SICK
  3. Encoders
Encoders Absolute encoders Incremental encoders Linear encoders Measuring wheel encoders Safety encoders Wire draw encoders Encoder accessories

Encoders Items 6433 - 6528 de 10132 ⍾ SICK ⍾ Última modificación Jun 6, 2026

Catalog up Absolute encoders Incremental encoders Linear encoders Measuring wheel encoders Safety encoders Wire draw encoders Encoder accessories

Encoders ⍾ Página 68

  • « Anterior
  • 1
  • 22
  • 43
  • 64
  • 85
  • 106
  • » Siguiente
  • SICK DFS60I-BEMC65536 (1083937)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BEMC65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-BENK01024 (1091416)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BENK01024

    Performance: Periods per revolution: 1,024; Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; …

  • SICK DFS60I-BEPC65536 (1080553)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BEPC65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-BEPK65536 (1083939)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BEPK65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-BEPM65536 (1083938)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BEPM65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-BFCC36000 (1092427)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BFCC36000

    Performance: Pulses per revolution: 36,000 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± …

  • SICK DFS60I-BFCC65536 (1097193)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BFCC65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-BFEC00350 (1088504)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BFEC00350

    Performance: Pulses per revolution: 350 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0. …

  • SICK DFS60I-BFPC65536 (1091414)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BFPC65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-BFWC01000 (1099061)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BFWC01000

    Codificador incremental, modelo DFS60 (DFS60I-BFWC01000), con eje hueco ciego de 1/2 pulgada y clasificación IP67 en acero inoxidable V2A. Funciona con HTL de 4,5 V a 32 V, interfa …

  • SICK DFS60I-BGNM01024 (1096941)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BGNM01024

    Performance: Periods per revolution: 1,024; Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; …

  • SICK DFS60I-BGPC65536 (1089962)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BGPC65536

    Codificador incremental, modelo DFS60 (DFS60I-BGPC65536), con un eje hueco ciego de 14 mm y clasificación IP67 en acero inoxidable V2A. Soporta una interfaz de comunicación de 4,5  …

  • SICK DFS60I-BGPM65536 (1085770)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BGPM65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-BGPN65536 (1104607)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BGPN65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-BHCC01024 (1099311)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BHCC01024

    Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03 …

  • SICK DFS60I-BHCK01024 (1085559)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BHCK01024

    Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03 …

  • SICK DFS60I-BHEC00100 (1085519)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BHEC00100

    Performance: Pulses per revolution: 100 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0. …

  • SICK DFS60I-BHEC01024 (1099829)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BHEC01024

    Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03 …

  • SICK DFS60I-BHMC65536 (1098278)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BHMC65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-BHNC01024 (1095904)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BHNC01024

    Performance: Periods per revolution: 1,024; Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; …

  • SICK DFS60I-BHPC65536 (1091640)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BHPC65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-BHPK65536 (1085558)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BHPK65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-BHPM65536 (1095705)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BHPM65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-BJEC65536 (1085646)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BJEC65536

    Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03 …

  • SICK DFS60I-BJEK01024 (1101287)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BJEK01024

    Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03 …

  • SICK DFS60I-BJNC01024 (1098157)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BJNC01024

    Performance: Periods per revolution: 1,024; Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; …

  • SICK DFS60I-BJPK65536 (1087382)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BJPK65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-BJWC01000 (1104089)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-BJWC01000

    Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ±  …

  • SICK DFS60I-Q4AC02500 (1083393)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-Q4AC02500

    Performance: Pulses per revolution: 2,500 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ±  …

  • SICK DFS60I-Q4AC08192 (1085776)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-Q4AC08192

    Performance: Pulses per revolution: 8,192 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03 …

  • SICK DFS60I-Q4CC01000 (1092995)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-Q4CC01000

    Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ±  …

  • SICK DFS60I-Q4MC65536 (1083945)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-Q4MC65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-Q4MK65536 (1093571)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-Q4MK65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-Q4PC65536 (1083963)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-Q4PC65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-Q4PK65536 (1083947)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-Q4PK65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-Q4PM65536 (1083946)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-Q4PM65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-S1AC02500 (1083385)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S1AC02500

    Performance: Pulses per revolution: 2,500 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ±  …

  • SICK DFS60I-S1AC65536 (1104736)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S1AC65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-S1CC65536 (1106952)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S1CC65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-S1EK02000 (1087576)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S1EK02000

    Performance: Pulses per revolution: 2,000 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ±  …

  • SICK DFS60I-S1MC65536 (1083964)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S1MC65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-S1PC65536 (1083967)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S1PC65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-S1PK65536 (1083966)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S1PK65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-S1PM65536 (1083965)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S1PM65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-S1VK65536 (1098418)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S1VK65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-S1WC00512 (1106240)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S1WC00512

    Performance: Pulses per revolution: 512 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; …

  • SICK DFS60I-S4AC01024 (1094116)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4AC01024

    Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03 …

  • SICK DFS60I-S4AC02048 (1099033)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4AC02048

    Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03 …

  • SICK DFS60I-S4AC04000 (1092993)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4AC04000

    Performance: Pulses per revolution: 4,000 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ±  …

  • SICK DFS60I-S4AC04096 (1085845)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4AC04096

    Performance: Pulses per revolution: 4,096 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03 …

  • SICK DFS60I-S4AC10000 (1104888)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4AC10000

    Performance: Pulses per revolution: 10,000 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± …

  • SICK DFS60I-S4AC32768 (1103954)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4AC32768

    Performance: Pulses per revolution: 32,768 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-S4AK05000 (1089244)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4AK05000

    Performance: Pulses per revolution: 5,000 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ±  …

  • SICK DFS60I-S4CC01024 (1095706)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4CC01024

    Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03 …

  • SICK DFS60I-S4CC04096 (1101883)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4CC04096

    Performance: Pulses per revolution: 4,096 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03 …

  • SICK DFS60I-S4CM65536 (1100722)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4CM65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-S4CN02048 (1093855)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4CN02048

    Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03 …

  • SICK DFS60I-S4EC00360 (1086935)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4EC00360

    Performance: Pulses per revolution: 360 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0. …

  • SICK DFS60I-S4EC00500 (1097613)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4EC00500

    Performance: Pulses per revolution: 500 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0. …

  • SICK DFS60I-S4EC00900 (1086934)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4EC00900

    Performance: Pulses per revolution: 900 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0. …

  • SICK DFS60I-S4EC01000 (1092527)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4EC01000

    Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ±  …

  • SICK DFS60I-S4EC01024 (1091998)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4EC01024

    Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03 …

  • SICK DFS60I-S4EC01800 (1086933)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4EC01800

    Performance: Pulses per revolution: 1,800 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ±  …

  • SICK DFS60I-S4EK00100 (1105660)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4EK00100

    Performance: Pulses per revolution: 100 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0. …

  • SICK DFS60I-S4EK01800 (1087577)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4EK01800

    Performance: Pulses per revolution: 1,800 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ±  …

  • SICK DFS60I-S4EM00641 (1084885)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4EM00641

    Performance: Pulses per revolution: 641 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0. …

  • SICK DFS60I-S4EM65536 (1100721)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4EM65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-S4MC65536 (1083968)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4MC65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-S4NK01024 (1092426)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4NK01024

    Performance: Periods per revolution: 1,024; Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; …

  • SICK DFS60I-S4NL01024 (1101201)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4NL01024

    Performance: Periods per revolution: 1,024; Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; …

  • SICK DFS60I-S4NM01024 (1096635)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4NM01024

    Performance: Periods per revolution: 1,024; Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; …

  • SICK DFS60I-S4PC01024 (1106600)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4PC01024

    Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03 …

  • SICK DFS60I-S4PC10000 (1104904)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4PC10000

    Performance: Pulses per revolution: 10,000 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± …

  • SICK DFS60I-S4PC32678 (1102682)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4PC32678

    Performance: Pulses per revolution: 32,678 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± …

  • SICK DFS60I-S4PC65536 (1083971)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4PC65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-S4PK65536 (1083970)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4PK65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-S4PL65536 (1104603)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4PL65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-S4PM65536 (1083969)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4PM65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-S4VC65536 (1106364)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4VC65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-S4VK03600 (1090662)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4VK03600

    Performance: Pulses per revolution: 3,600 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ±  …

  • SICK DFS60I-S4WC01000 (1103525)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4WC01000

    Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ±  …

  • SICK DFS60I-S4WC01800 (1087638)
    Detalles Añadir a SDC Añadir a SDC

    DFS60I-S4WC01800

    Performance: Pulses per revolution: 1,800 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ±  …

  • SICK DFS60S-BAOA01024 (1081573)
    Detalles Añadir a SDC Añadir a SDC

    DFS60S-BAOA01024

    Safety-related parameters: Safety integrity level: SIL2 (IEC 61508), SILCL2 (IEC 62061) 1); Performance level: PL d (EN ISO 13849) 1); Category: 3 (EN ISO 13849); PFHD: Probability …

  • SICK DFS60S-BAOJ01024 (1083146)
    Detalles Añadir a SDC Añadir a SDC

    DFS60S-BAOJ01024

    Safety-related parameters: Safety integrity level: SIL2 (IEC 61508), SILCL2 (IEC 62061) 1); Performance level: PL d (EN ISO 13849) 1); Category: 3 (EN ISO 13849); PFHD: Probability …

  • SICK DFS60S-BAOK01024 (1083278)
    Detalles Añadir a SDC Añadir a SDC

    DFS60S-BAOK01024

    Safety-related parameters: Safety integrity level: SIL2 (IEC 61508), SILCL2 (IEC 62061) 1); Performance level: PL d (EN ISO 13849) 1); Category: 3 (EN ISO 13849); PFHD: Probability …

  • SICK DFS60S-BAOL01024 (1084340)
    Detalles Añadir a SDC Añadir a SDC

    DFS60S-BAOL01024

    Safety-related parameters: Safety integrity level: SIL2 (IEC 61508), SILCL2 (IEC 62061) 1); Performance level: PL d (EN ISO 13849) 1); Category: 3 (EN ISO 13849); PFHD: Probability …

  • SICK DFS60S-BBOC01024 (1088523)
    Detalles Añadir a SDC Añadir a SDC

    DFS60S-BBOC01024

    Safety-related parameters: Safety integrity level: SIL2 (IEC 61508), SILCL2 (IEC 62061) 1); Performance level: PL d (EN ISO 13849) 1); Category: 3 (EN ISO 13849); PFHD: Probability …

  • SICK DFS60S-BBOK01024 (1079605)
    Detalles Añadir a SDC Añadir a SDC

    DFS60S-BBOK01024

    Safety-related parameters: Safety integrity level: SIL2 (IEC 61508), SILCL2 (IEC 62061) 1); Performance level: PL d (EN ISO 13849) 1); Category: 3 (EN ISO 13849); PFHD: Probability …

  • SICK DFS60S-BBOL01024 (1103054)
    Detalles Añadir a SDC Añadir a SDC

    DFS60S-BBOL01024

    Safety-related parameters: Safety integrity level: SIL2 (IEC 61508), SILCL2 (IEC 62061) 1); Performance level: PL d (EN ISO 13849) 1); Category: 3 (EN ISO 13849); PFHD: Probability …

  • SICK DFS60S-BBON01024 (1088500)
    Detalles Añadir a SDC Añadir a SDC

    DFS60S-BBON01024

    Safety-related parameters: Safety integrity level: SIL2 (IEC 61508), SILCL2 (IEC 62061) 1); Performance level: PL d (EN ISO 13849) 1); Category: 3 (EN ISO 13849); PFHD: Probability …

  • SICK DFS60S-BDOA00S01 (1093703)
    Detalles Añadir a SDC Añadir a SDC

    DFS60S-BDOA00S01

    Features: Special device: ✔; Specialty: Long statour coupling premounted; Standard reference device: DFS60S-BDOA01024, 1069535; Safety-related parameters: Safety integrity level: S …

  • SICK DFS60S-BDOA01024 (1069535)
    Detalles Añadir a SDC Añadir a SDC

    DFS60S-BDOA01024

    Safety-related parameters: Safety integrity level: SIL2 (IEC 61508), SILCL2 (IEC 62061) 1); Performance level: PL d (EN ISO 13849) 1); Category: 3 (EN ISO 13849); PFHD: Probability …

  • SICK DFS60S-BDOC01024 (1067915)
    Detalles Añadir a SDC Añadir a SDC

    DFS60S-BDOC01024

    Safety-related parameters: Safety integrity level: SIL2 (IEC 61508), SILCL2 (IEC 62061) 1); Performance level: PL d (EN ISO 13849) 1); Category: 3 (EN ISO 13849); PFHD: Probability …

  • SICK DFS60S-BDOK01024 (1069536)
    Detalles Añadir a SDC Añadir a SDC

    DFS60S-BDOK01024

    Safety-related parameters: Safety integrity level: SIL2 (IEC 61508), SILCL2 (IEC 62061) 1); Performance level: PL d (EN ISO 13849) 1); Category: 3 (EN ISO 13849); PFHD: Probability …

  • SICK DFS60S-BEOA01024 (1069537)
    Detalles Añadir a SDC Añadir a SDC

    DFS60S-BEOA01024

    Safety-related parameters: Safety integrity level: SIL2 (IEC 61508), SILCL2 (IEC 62061) 1); Performance level: PL d (EN ISO 13849) 1); Category: 3 (EN ISO 13849); PFHD: Probability …

  • SICK DFS60S-BEOC01024 (1069538)
    Detalles Añadir a SDC Añadir a SDC

    DFS60S-BEOC01024

    Codificadores de seguridad | DFS60S Pro | DFS60S-BEOC01024 | Nivel de integridad de seguridad: SIL 2 (IEC 61508), SILCL2 (IEC 62061) | Nivel de rendimiento: PL d (EN ISO 13849) | D …

« Anterior Siguiente »

SICK ⍾ Recientemente actualizado

MRA-F080-102D2 MICS3-AAAZ55AZ1P01 KTX-WP92141252ZZZZ KTX-WB9214225AZZZZ DOL-1204-G02MNI BEF-AP8-MPB YM2D24-C50PN1MRJA4 YG2A14-100VB3XLEAX YF8U14-100VA3XLEAX YF8U13-050VA1XLEAX
  • Inicio
  • Sobre nosotros
  • Privacy policy
  • Seleccione brand
    ABB BANNER Baumer BECKHOFF Danfoss ifm INNOMOTICS Keyence Murrelektronik OBO Omron Pepperl+Fuchs Phoenix Contact PILZ Schneider Electric SICK SIEMENS Telemecanique Turck Weidmüller WEINTEK Yaskawa
  • Contacto
  • Español es Español
    English Deutsch Español Polski
  • Añadir a SDC Solicitud de Cotización

© INT TECHNICS Sp. z o.o.

Żadna z przedstawionych w serwisie stron nie jest ofertą w rozumieniu Kodeksu Cywilnego. Jeśli w opisie prezentowanego produktu występuje cena, ma ona wyłącznie charakter orientacyjny. Loga i nazwy firm są własnością ich prawnych właścicieli i zostały użyte tylko w celach informacyjnych.

Spam kieruj na oumuamua@int-technics.pl