SIEMENS 3VT2 (to 250 A) to 65 kA Items 1 - 58 de 58 ⍾ SIEMENS ⍾ Última modificación
The SIEMENS 3VT2 (to 250 A) to 65 kA catalog includes electronic trip units, switch disconnectors, and a variety of accessories. Products are designed for motor and transformer protection, installation protection, and feature overload and short-circuit protection. Accessories encompass motorized operating mechanisms, undervoltage trip units, auxiliary switches, and interlocks, catering to diverse operational and safety requirements.
3VT2 (to 250 A) to 65 kA ⍾ Página 1
-
3VT2725-2AA33-0AA0
CIRCUIT BREAKER 3VT2 STANDARD SWITCHING CAPACITY ICU=36KA, 415V AC 3-POLE; CIRCUIT BREAKER W/O ELECTRONIC TRIP UNIT W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXIL …
-
3VT2725-2AA36-0AA0
INTERRUPT. AUTOMAT. 3VT2 PODER DE CORTE ESTANDAR ICU=36KA, 415V AC 3POLOS; INTERRUPT. AUTOMAT. S. DISPARAD. DE SOBREINTENS. S. DISPARADOR AUXILIAR S. CONTACTO AUXIL./ALARMA SIN DIS …
-
3VT2725-2AA43-0AA0
CIRCUIT BREAKER 3VT2 STANDARD SWITCHING CAPACITY ICU=36KA, 415V AC 4-POLE; CIRCUIT BREAKER W/O ELECTRONIC TRIP UNIT N SWITCHED W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WI …
-
3VT2725-2AA46-0AA0
INTERRUPT. AUTOMAT. 3VT2 PODER DE CORTE ESTANDAR ICU=36KA, 415V AC 4POLOS; INTERRUPT. AUTOMAT. S. DISPARAD. DE SOBREINTENS. N CONMUTADO S. DISPARADOR AUXILIAR S. CONTACTO AUXIL./AL …
-
3VT2725-2AA53-0AA0
CIRCUIT BREAKER 3VT2 STANDARD SWITCHING CAPACITY ICU=36KA, 415V AC 4-POLE; CIRCUIT BREAKER W/O ELECTRONIC TRIP UNIT N MEASURED + SWITCHED W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALAR …
-
3VT2725-2AA56-0AA0
INTERRUPT. AUTOMAT. 3VT2 PODER DE CORTE ESTANDAR ICU=36KA, 415V AC 4POLOS; INTERRUPT. AUTOMAT. S. DISPARAD. DE SOBREINTENS. N CONMUTADO + MEDIDO S. DISPARADOR AUXILIAR S. CONTACTO …
-
3VT2725-2DE36-0AA0
INTERRUPT.-SECCIONAD. 3VT2 3POLOS; INTERRUPT.-SECCIONAD. IN= 250A INTENSIDAD ASIGNADA S. DISPARADOR AUXILIAR S. CONTACTO AUXIL./ALARMA SIN DISPARADOR AUXILIAR SIN CONTACTO AUXILIAR …
-
-
3VT2725-3AA33-0AA0
CIRCUIT BREAKER 3VT2 HIGH SWITCHING CAPACITY ICU=65KA, 415V AC 3-POLE; CIRCUIT BREAKER W/O ELECTRONIC TRIP UNIT W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOUT AUXILIARY …
-
3VT2725-3AA36-0AA0
INTERRUPT. AUTOMAT. 3VT2 ELEVADO PODER DE CORTE ICU=65KA, 415V AC 3POLOS; INTERRUPT. AUTOMAT. S. DISPARAD. DE SOBREINTENS. S. DISPARADOR AUXILIAR S. CONTACTO AUXIL./ALARMA SIN DISP …
-
3VT2725-3AA43-0AA0
CIRCUIT BREAKER 3VT2 HIGH SWITCHING CAPACITY ICU=65KA, 415V AC 4-POLE; CIRCUIT BREAKER W/O ELECTRONIC TRIP UNIT N SWITCHED W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SWITCH WITHOU …
-
3VT2725-3AA46-0AA0
INTERRUPT. AUTOMAT. 3VT2 ELEVADO PODER DE CORTE ICU=65KA, 415V AC 4POLOS; INTERRUPT. AUTOMAT. S. DISPARAD. DE SOBREINTENS. N CONMUTADO S. DISPARADOR AUXILIAR S. CONTACTO AUXIL./ALA …
-
3VT2725-3AA53-0AA0
CIRCUIT BREAKER 3VT2 HIGH SWITCHING CAPACITY ICU=65KA, 415V AC 4-POLE; CIRCUIT BREAKER W/O ELECTRONIC TRIP UNIT N MEASURED + SWITCHED W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM SW …
-
3VT2725-3AA56-0AA0
INTERRUPT. AUTOMAT. 3VT2 ELEVADO PODER DE CORTE ICU=65KA, 415V AC 4POLOS; INTERRUPT. AUTOMAT. S. DISPARAD. DE SOBREINTENS. N CONMUTADO + MEDIDO S. DISPARADOR AUXILIAR S. CONTACTO A …
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3VT9210-6AS00
DISIP. DE SOBREINTENS. VT250 3 POLOS, PROTEC. MOTOR/TRANSF. ETU MPS, LSI IR= 40...100A, PROTEC. CONTRA SOBRECARGAS IRM= 3... 9KA PROTEC. CONTRA CORTOCIRCUITO, CONEXIONES POR TORNIL …
-
3VT9210-6BC00
ELECTRONIC TRIP UNIT VT250 4-POLE, SYSTEM PROTECTION ETU DPN, LI IR= 40...100A, OVERLOAD PROTECTION IRM= 4... 8KA SHORT-CIRCUIT PROTECTION, NEUTRAL CONDUCTOR PROTECT. IRN=0.5 TO 1X …
-
-
3VT9216-6AS00
DISIP. DE SOBREINTENS. VT250 3 POLOS, PROTEC. MOTOR/TRANSF. ETU MPS, LSI IR= 63...160A, PROTEC. CONTRA SOBRECARGAS IRM= 3... 9KA PROTEC. CONTRA CORTOCIRCUITO, CONEXIONES POR TORNIL …
-
3VT9216-6BC00
ELECTRONIC TRIP UNIT VT250 4-POLE, SYSTEM PROTECTION ETU DPN, LI IR= 63...160A, OVERLOAD PROTECTION IRM= 4... 8KA SHORT-CIRCUIT PROTECTION, NEUTRAL CONDUCTOR PROTECT. IRN=0.5 TO 1X …
-
-
-
-
-
3VT9225-6BC00
ELECTRONIC TRIP UNIT VT250 4-POLE, SYSTEM PROTECTION ETU DPN, LI IR= 100...250A, OVERLOAD PROTECTION IRM= 4... 8KA SHORT-CIRCUIT PROTECTION, NEUTRAL CONDUCTOR PROTECT. IRN=0.5 TO 1 …
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-