Temperature measurement Items 385 - 480 of 1363 ⍾ SIEMENS ⍾ Last modified
Temperature measurement ⍾ Page 5
-
7MC3040-2AB35
SPECTRALPYROMETER PA35AF1L ARDOCELL, MEASURING RANGE 600-3000 CEL, DISTANCE RATIO 210:1 (90%), FOCAL RANGE 0,4 M..UNENDL, SPECTRAL RANGE 0,85-0,91 1E-6 M VERSION WITH LASER SPOT …
-
-
7MC3040-2AB43
TWO-COLOUR PYROMETER PA43AF1L ARDOCELL, MEASURING RANGE 650-1700 CEL, DIST. RATIO DV=230:1,DH=45:1, FOCAL RANGE 0,4 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER …
-
-
7MC3040-2AC15
SPECTRALPYROMETER PA15AF2L ARDOCELL, MEASURING RANGE 300-1300CEL, DISTANCE RATIO 40:1 (90%), FOCAL RANGE 0,3M..UNENDL, SPECTRAL RANGE 4,46-4,82 1E-6 M VERSION WITH LASER SPOT LIG …
-
7MC3040-2AC20
SPECTRALPYROMETER PA20AF2L ARDOCELL, MEASURING RANGE 250-2000 CEL, DISTANCE RATIO 150:1 (90%), FOCAL RANGE 0,2 M..0,4 M, SPECTRAL RANGE 1,1-1,7 1E-6 M VERSION WITH LASER SPOT LIG …
-
7MC3040-2AC30
SPECTRALPYROMETER PA30AF2L ARDOCELL, MEASURING RANGE 500-2500 CEL, DISTANCE RATIO 200:1 (90%), FOCAL RANGE 0,2 M..0,4 M, SPECTRAL RANGE 0,78-1,06 1E-6 M VERSION WITH LASER SPOT L …
-
7MC3040-2AC35
SPECTRALPYROMETER PA35AF2L ARDOCELL, MEASURING RANGE 600-3000 CEL, DISTANCE RATIO 200:1 (90%), FOCAL RANGE 0,2 M..0,4 M, SPECTRAL RANGE 0,85-0,91 1E-6 M VERSION WITH LASER SPOT L …
-
-
7MC3040-2AC43
TWO-COLOUR PYROMETER PA43AF2L ARDOCELL, MEASURING RANGE 650-1700 CEL, DIST. RATIO DV=215:1,DH=40:1, FOCAL RANGE 0,2..0,4 M, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER SPO …
-
7MC3040-2AD20
SPECTRALPYROMETER PA20AF3L ARDOCELL, MEASURING RANGE 250-2000 CEL, DISTANCE RATIO 275:1 (90%), FOCAL RANGE 1,2 M..UNENDL, SPECTRAL RANGE 1,1-1,7 1E-6 M VERSION WITH LASER SPOT LI …
-
7MC3040-2AD30
SPECTRALPYROMETER PA30AF3L ARDOCELL, MEASURING RANGE 500-2500 CEL, DISTANCE RATIO 310:1 (90%), FOCAL RANGE 1,2 M..UNENDL, SPECTRAL RANGE 0,78-1,06 1E-6 M VERSION WITH LASER SPOT …
-
7MC3040-2AD35
SPECTRALPYROMETER PA35AF3L ARDOCELL, MEASURING RANGE 600-3000 CEL, DISTANCE RATIO 310:1 (90%), FOCAL RANGE 1,2 M..UNENDL, SPECTRAL RANGE 0,85-0,91 1E-6 M VERSION WITH LASER SPOT …
-
7MC3040-2AD40
TWO-COLOUR PYROMETER PA40AF3L ARDOCELL, MEASURING RANGE 650-1700 CEL, DISTANCE RATIO 120:1, FOCAL RANGE 1,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER SPOT LIG …
-
7MC3040-2AD43
TWO-COLOUR PYROMETER PA43AF3L ARDOCELL, MEASURING RANGE 650-1700 CEL, DIST. RATIO DV=375:1,DH=75:1, FOCAL RANGE 1,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER …
-
7MC3040-2AE20
SPECTRALPYROMETER PA20AF4L ARDOCELL, MEASURING RANGE 250-2000 CEL, DISTANCE RATIO 40:1 (90%), FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 1,1-1,7 1E-6 M VERSION WITH LASER SPOT LIG …
-
7MC3040-2AE30
SPECTRALPYROMETER PA30AF4L ARDOCELL, MEASURING RANGE 500-2500 CEL, DISTANCE RATIO 55:1 (90%), FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 0,78-1,06 1E-6 M VERSION WITH LASER SPOT L …
-
7MC3040-2AE35
SPECTRALPYROMETER PA35AF4L ARDOCELL, MEASURING RANGE 600-3000 CEL, DISTANCE RATIO 55:1 (90%), FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 0,85-0,91 1E-6 M VERSION WITH LASER SPOT L …
-
7MC3040-2AE40
TWO-COLOUR PYROMETER PA40AF4L ARDOCELL, MEASURING RANGE 750-2400 CEL, DISTANCE RATIO 150:1, FOCAL RANGE 0,4 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER SPOT LIG …
-
7MC3040-2AE43
TWO-COLOUR PYROMETER PA43AF4L ARDOCELL, MEASURING RANGE 750-2400 CEL, DIST. RATIO DV=350:1,DH=50:1, FOCAL RANGE 0,4 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER …
-
7MC3040-2AF20
SPECTRALPYROMETER PA20AF5L ARDOCELL, MEASURING RANGE 350-2500 CEL, DISTANCE RATIO 175:1 (90%), FOCAL RANGE 0,4 M..UNENDL, SPECTRAL RANGE 1,1-1,7 1E-6 M VERSION WITH LASER SPOT LI …
-
-
7MC3040-2AF43
TWO-COLOUR PYROMETER PA43AF5L ARDOCELL, MEASURING RANGE 750-2400 CEL, DIST. RATIO DV=330:1,DH=45:1, FOCAL RANGE 0,2..0,4 M, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER SPO …
-
7MC3040-2AG20
SPECTRALPYROMETER PA20AF6L ARDOCELL, MEASURING RANGE 350-2500 CEL, DISTANCE RATIO 150:1 (90%), FOCAL RANGE 0,2 M..0,4 M, SPECTRAL RANGE 1,1-1,7 1E-6 M VERSION WITH LASER SPOT LIG …
-
7MC3040-2AG40
TWO-COLOUR PYROMETER PA40AF6L ARDOCELL, MEASURING RANGE 750-2400 CEL, DISTANCE RATIO 240:1, FOCAL RANGE 1,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER SPOT LIG …
-
7MC3040-2AG43
TWO-COLOUR PYROMETER PA43AF6L ARDOCELL, MEASURING RANGE 750-2400 CEL, DIST. RATIO DV=580:1,DH=85:1, FOCAL RANGE 1,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER …
-
7MC3040-2AG80
TWO-COLOUR PYROMETER PA80AF6L ARDOCELL, MEASURING RANGE 750-2400 CEL, DISTANCE RATIO 240:1, FOCAL RANGE 1,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER SPOT LIG …
-
7MC3040-2AH20
SPECTRALPYROMETER PA20AF7L ARDOCELL, MEASURING RANGE 350-2500 CEL, DISTANCE RATIO 275:1 (90%), FOCAL RANGE 1,2 M..UNENDL, SPECTRAL RANGE 1,1-1,7 1E-6 M VERSION WITH LASER SPOT LI …
-
7MC3040-2AH40
TWO-COLOUR PYROMETER PA40AF7L ARDOCELL, MEASURING RANGE 850-3000 CEL, DISTANCE RATIO 150:1, FOCAL RANGE 0,4 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER SPOT LIG …
-
7MC3040-2AH43
TWO-COLOUR PYROMETER PA43AF7L ARDOCELL, MEASURING RANGE 850-3000 CEL, DIST. RATIO DV=350:1,DH=50:1, FOCAL RANGE 0,4 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER …
-
7MC3040-2AJ20
SPECTRALPYROMETER PA20AF8L ARDOCELL, MEASURING RANGE 350-2500 CEL, DISTANCE RATIO 40:1 (90%), FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 1,1-1,7 1E-6 M VERSION WITH LASER SPOT LIG …
-
-
7MC3040-2AJ43
TWO-COLOUR PYROMETER PA43AF8L ARDOCELL, MEASURING RANGE 850-3000 CEL, DIST. RATIO DV=330:1,DH=45:1, FOCAL RANGE 0,2..0,4 M, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER SPO …
-
7MC3040-2AK40
TWO-COLOUR PYROMETER PA40AF9L ARDOCELL, MEASURING RANGE 850-3000 CEL, DISTANCE RATIO 240:1, FOCAL RANGE 1,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER SPOT LIG …
-
7MC3040-2AK43
TWO-COLOUR PYROMETER PA43AF9L ARDOCELL, MEASURING RANGE 850-3000 CEL, DIST. RATIO DV=580:1,DH=85:1, FOCAL RANGE 1,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER …
-
7MC3040-2BA40
TWO-COLOUR PYROMETER PA40AF10L ARDOCELL, MEASURING RANGE 650-1700 CEL, DISTANCE RATIO 20:1, FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER SPOT LIG …
-
7MC3040-2BA43
TWO-COLOUR PYROMETER PA43AF10L ARDOCELL, MEASURING RANGE 650-1700 CEL, DIST. RATIO DV=55:1,DH=10:1, FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER …
-
7MC3040-2BB40
TWO-COLOUR PYROMETER PA40AF11L ARDOCELL, MEASURING RANGE 750-2400 CEL, DISTANCE RATIO 35:1, FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER SPOT LIG …
-
7MC3040-2BB43
TWO-COLOUR PYROMETER PA43AF11L ARDOCELL, MEASURING RANGE 750-2400 CEL, DIST. RATIO DV=85:1,DH=11:1, FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER …
-
7MC3040-2BC40
TWO-COLOUR PYROMETER PA40AF12L ARDOCELL, MEASURING RANGE 850-3000 CEL, DISTANCE RATIO 35:1, FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER SPOT LIG …
-
7MC3040-2BC43
TWO-COLOUR PYROMETER PA43AF12L ARDOCELL, MEASURING RANGE 850-3000 CEL, DIST. RATIO DV=85:1,DH=11:1, FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER …
-
7MC3040-2BD43
TWO-COLOUR PYROMETER PA43AF13L ARDOCELL, MEASURING RANGE 650-1700 CEL, DIST. RATIO DV=150:1,DH=30:1, FOCAL RANGE 0,3 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER …
-
7MC3040-2BE43
TWO-COLOUR PYROMETER PA43AF14L ARDOCELL, MEASURING RANGE 750-2400 CEL, DIST. RATIO DV=230:1,DH=34:1, FOCAL RANGE 0,3 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER …
-
7MC3040-2BF43
TWO-COLOUR PYROMETER PA43AF15L ARDOCELL, MEASURING RANGE 850-3000 CEL, DIST. RATIO DV=230:1,DH=34:1, FOCAL RANGE 0,3 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER …
-
7MC3040-2CA40
TWO-COLOUR PYROMETER PA40AF20L ARDOCELL, MEASURING RANGE 500-1400 CEL, DISTANCE RATIO 55:1, FOCAL RANGE 0,3 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH LASER SPOT LIG …
-
-
-
-
-
-
-
-
7MC3040-3AB43
TWO-COLOUR PYROMETER PA43AF1C ARDOCELL, MEASURING RANGE 650-1700 CEL, DIST. RATIO DV=230:1,DH=45:1, FOCAL RANGE 0,4 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH CAMERA …
-
7MC3040-3AB83
TWO-COLOUR PYROMETER PA83AF1C ARDOCELL, MEASURING RANGE 650-1700 CEL, DIST. RATIO DV=230:1,DH=45:1, FOCAL RANGE 0,4 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH CAMERA …
-
-
-
-
-
-
-
7MC3040-3AC43
TWO-COLOUR PYROMETER PA43AF2C ARDOCELL, MEASURING RANGE 650-1700 CEL, DIST. RATIO DV=215:1,DH=40:1, FOCAL RANGE 0,2..0,4 M, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH CAMERA RE …
-
-
-
-
-
7MC3040-3AD43
TWO-COLOUR PYROMETER PA43AF3C ARDOCELL, MEASURING RANGE 650-1700 CEL, DIST. RATIO DV=375:1,DH=75:1, FOCAL RANGE 1,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH CAMERA …
-
7MC3040-3AD83
TWO-COLOUR PYROMETER PA83AF3C ARDOCELL, MEASURING RANGE 650-1700 CEL, DIST. RATIO DV=375:1,DH=75:1, FOCAL RANGE 1,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH CAMERA …
-
-
-
-
-
7MC3040-3AE43
TWO-COLOUR PYROMETER PA43AF4C ARDOCELL, MEASURING RANGE 750-2400 CEL, DIST. RATIO DV=350:1,DH=50:1, FOCAL RANGE 0,4 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH CAMERA …
-
-
-
7MC3040-3AF43
TWO-COLOUR PYROMETER PA43AF5C ARDOCELL, MEASURING RANGE 750-2400 CEL, DIST. RATIO DV=330:1,DH=45:1, FOCAL RANGE 0,2..0,4 M, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH CAMERA RE …
-
-
-
7MC3040-3AG43
TWO-COLOUR PYROMETER PA43AF6C ARDOCELL, MEASURING RANGE 750-2400 CEL, DIST. RATIO DV=580:1,DH=85:1, FOCAL RANGE 1,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH CAMERA …
-
-
-
-
7MC3040-3AH43
TWO-COLOUR PYROMETER PA43AF7C ARDOCELL, MEASURING RANGE 850-3000 CEL, DIST. RATIO DV=350:1,DH=50:1, FOCAL RANGE 0,4 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH CAMERA …
-
-
-
7MC3040-3AJ43
TWO-COLOUR PYROMETER PA43AF8C ARDOCELL, MEASURING RANGE 850-3000 CEL, DIST. RATIO DV=330:1,DH=45:1, FOCAL RANGE 0,2..0,4 M, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH CAMERA RE …
-
-
7MC3040-3AK43
TWO-COLOUR PYROMETER PA43AF9C ARDOCELL, MEASURING RANGE 850-3000 CEL, DIST. RATIO DV=580:1,DH=85:1, FOCAL RANGE 1,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH CAMERA …
-
-
7MC3040-3BA43
TWO-COLOUR PYROMETER PA43AF10C ARDOCELL, MEASURING RANGE 650-1700 CEL, DIST. RATIO DV=55:1,DH=10:1, FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH CAMERA …
-
7MC3040-3BA83
TWO-COLOUR PYROMETER PA83AF10C ARDOCELL, MEASURING RANGE 650-1700 CEL, DIST. RATIO DV=55:1,DH=10:1, FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH CAMERA …
-
-
7MC3040-3BB43
TWO-COLOUR PYROMETER PA43AF11C ARDOCELL, MEASURING RANGE 750-2400 CEL, DIST. RATIO DV=85:1,DH=11:1, FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH CAMERA …
-
-
7MC3040-3BC43
TWO-COLOUR PYROMETER PA43AF12C ARDOCELL, MEASURING RANGE 850-3000 CEL, DIST. RATIO DV=85:1,DH=11:1, FOCAL RANGE 0,2 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH CAMERA …
-
7MC3040-3BD43
TWO-COLOUR PYROMETER PA43AF13C ARDOCELL, MEASURING RANGE 650-1700 CEL, DIST. RATIO DV=150:1,DH=30:1, FOCAL RANGE 0,3 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH CAMER …
-
7MC3040-3BD83
TWO-COLOUR PYROMETER PA83AF13C ARDOCELL, MEASURING RANGE 650-1700 CEL, DIST. RATIO DV=150:1,DH=30:1, FOCAL RANGE 0,3 M..UNENDL, SPECTRAL RANGE 0,95/1,05 1E-6 M VERSION WITH CAMER …