PILZ PNOZ X - safety relays / PNOZ Page 2 ⍾ PILZ ⍾ Last modified
The PILZ PNOZ X catalog features standalone safety relays designed for various applications. These relays offer 1- or 2-channel wiring options, with or without short-circuit detection, and typically include automatic or monitored start functions. They commonly provide 3 N/O and 1 N/C outputs, with some models offering additional outputs and semiconductor outputs. Operating voltage ranges from 24 V DC to 240 V AC/DC, and widths vary from 22.5 mm to 90 mm. Various terminal types are available, including screw and spring-loaded terminals.
PNOZ / PNOZ X - safety relays ⍾ Page 2
-
PNOZ X2.7P C 24-240VAC/DC 3n/o 1n/c
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 3 N/O, 1 N/C. Monitored; start UB 24 - 240 V AC/DC, width: 22.5 mm, …
-
PNOZ X2.8P C 24-240VAC/DC 3n/o 1n/c
Safety relay (standalone), inputs: 1/2-channel wiring; with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,; automatic/manual start, UB 24 - 240 V AC/DC, width: …
-
PNOZ X3.10P 24VACDC 3n/o 1n/c 1so
Safety relay (standalone), inputs: 1/2-channel wiring; with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,1 SC,; automatic/monitored start, UB 24 V AC/DC, widt …
-
PNOZ X3 24VAC 24VDC 3n/o 1n/c 1so
Safety relay (standalone), inputs: 1/2-channel wiring; with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,1 SC,; automatic/monitored start, UB 24 V AC/DC, widt …
-
PNOZ X9 24VAC 24VDC 7n/o 2 n/c 2so
Safety relay (standalone), inputs: 1/2-channel wiring; with/without detection of shorts across contacts, outputs: 7 N/O, 2 N/C,2 SC; automatic/manual/monitored start and automatic …
-
PNOZ XV3.1 30/24VDC 3n/o 1n/c 2n/o t
Safety relay (standalone), inputs: 1/2-channel wiring; with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,2 STD, UB 24 V DC,; width: 90 mm, screw terminals int …
-
PNOZ XV3.1P 3/24VDC 3n/o 1n/c 2n/o t
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 3 N/O, 1 N/C, 2 N/O (t =; 0 - 300 s). Automatic/monitored start UB …
-
PNOZ 11 110-120VAC 24VDC 7n/o 1n/c
Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 7 N/O, 1 N/C,1 SC, automatic/manual/monitored start, start-up test, …
-
PNOZ 11 230-240VAC 24VDC 7n/o 1n/c
Safety relay (standalone), inputs: 1/2-channel wiring with detection of shorts across contacts, outputs: 3 N/O, 1 N/C, 1 SC, automatic/manual/monitored start, UB 230 - 240 V AC/24 …
-
PNOZ X10 110-120VAC 6n/o 4n/c 3LED
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 6 N/O, 4 N/C. Automatic/monitored start UB 110 - 120 V AC, width: 9 …
-
PNOZ X10.11P C 24VDC 6n/o 4n/c 6LED
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 7 N/O, 2 N/C, 2; semiconductor. Automatic/monitored start UB 24 V D …
-
PNOZ X10 230-240VAC 6n/o 4n/c 3LED
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 6 N/O, 4 N/C. Automatic/monitored start UB 230 - 240 V AC, width: 9 …
-
PNOZ X3.10P C 24VACDC 3n/o 1n/c 1so
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 3 N/O, 1 N/C, 1; semiconductor. Automatic/monitored start UB 24 V A …
-
PNOZ X3 110VAC 24VDC 3n/o 1n/c 1so
Safety relay (standalone), inputs: 1/2-channel wiring; with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,1 SC,; automatic/monitored start, UB 110 V AC/24 V DC …
-
PNOZ X3 115VAC 24VDC 3n/o 1n/c 1so
Safety relay (standalone), inputs: 1/2-channel wiring; with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,1 SC,; automatic/monitored start, UB 115 V AC/24 V DC …
-
PNOZ X3 120VAC 24VDC 3n/o 1n/c 1so
Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,1 SC, automatic/monitored start, UB 120 V AC/24 V DC, …
-
PNOZ X3 230VAC 24VDC 3n/o 1n/c 1so
Safety relay (standalone), inputs: 1/2-channel wiring; with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,1 SC,; automatic/monitored start, UB 230 V AC/24 V DC …
-
PNOZ X3P 24-240VACDC 3n/o 1n/c 1so
Safety relay (standalone), inputs: 1/2-channel wiring; with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,1 SC,; automatic/monitored start, UB 24 - 240V AC/DC, …
-
PNOZ X3P 24VDC 24VAC 3n/o 1n/c 1so
Safety relay (standalone), inputs: 1/2-channel wiring; with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,1 SC,; automatic/monitored start, UB 24 V AC/DC, widt …
-
PNOZ XV2.1 3/24-240VACDC 2n/o 2n/o t
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 2 N/O, 2 N/O delayed UB; 24-240 V AC/DC, width: 90 mm, integral scr …
-
PNOZ XV3.1 300/24VDC 3n/o 1n/c 2n/o t
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 3 N/O, 1 N/C, 2 N/O; delayed UB 24 V DC, width: 90 mm, integral scr …
-
PNOZ XV3.1P 30/24VDC 3n/o 1n/c 2n/o t
Safety relay (standalone), inputs: 1/2-channel wiring; with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/O(t = 0 - 30 s),; automatic/monitored start, UB 24 V DC …
-
PNOZ XV3.1P C 3/24VDC 3n/o 1n/c 2n/o t
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 3 N/O, 1 N/C, 2 N/O (t =; 0 - 3 s). Automatic/monitored start UB 24 …
-
PNOZ X10.1 230-240VAC 6n/o 4n/c 6LED
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 6 N/O, 4 N/C.; Automatic/monitored start UB 230 - 240 V AC, width: …
-
PNOZ X11P 24VAC 24VDC 7n/o 1n/c 2so
Safety relay (standalone), inputs: 1/2-channel wiring; with/without detection of shorts across contacts, outputs: 7 N/O, 1 N/C,2 SC,; automatic/manual/monitored start and automatic …
-
PNOZ X11P C 230-240VAC 7n/o 1n/c 2so
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 7 N/O, 1 N/C, 2; semiconductor. Automatic/monitored start UB 230 - …
-
PNOZ X3.1 230VAC 24VDC 3n/o 1n/c 1so
Safety relay (standalone) Inputs: 1- / 2-channel wiring with detection; of shorts across contacts Outputs: 3 N/O, 1 N/C, 1 semiconductor.; Automatic/monitored start UB 230 V AC/24 …
-
PNOZ X3.1 240VAC 24VDC 3n/o 1n/c 1so
Safety relay (standalone) Inputs: 1- / 2-channel wiring with detection; of shorts across contacts Outputs: 3 N/O, 1 N/C, 1 semiconductor.; Automatic/monitored start UB 240 V AC/24 …
-
PNOZ X3.2 230VAC 24VDC 3n/o 1n/c 1so
Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,1 SC, automatic/monitored start, UB = 230 V AC/24 V DC …
-
PNOZ X3P C 24-240VACDC 3n/o 1n/c 1so
Safety relay (standalone), inputs: 1/2-channel wiring; with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,1 SC; automatic/monitored start, UB 24 - 240 V AC/DC, …
-
PNOZ X3P C 24VDC 24VAC 3n/o 1n/c 1so
Safety relay (standalone), inputs: 1/2-channel wiring; with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,1 SC,; automatic/monitored start, UB 24 V AC/DC, widt …
-
PNOZ XV2.1 30/24-240VACDC 2n/o 2n/o t
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 2 N/O, 2 N/O delayed UB; 24-240 V AC/DC, width: 90 mm, integral scr …
-
PNOZ XV2.1P 3/24-240VACDC 2n/o 2n/o t
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 2 N/O, 2 N/O (t = 0 - 3 s); . Automatic/monitored start UB 24 - 240 …
-
PNOZ XV3.1P C 30/24VDC 3n/o 1n/c 2n/o t
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 3 N/O, 1 N/C, 2 N/O (t =; 0 - 30 s). Automatic/monitored start UB 2 …
-
PNOZ X11P C 24VAC 24VDC 7n/o 1n/c 2so
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 7 N/O, 1 N/C, 2; semiconductor. Automatic/monitored start UB 24 V A …
-
PNOZ XV2.1 300/24-240VACDC 2n/o 2n/o t
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 2 N/O, 2 N/O delayed. UB; 24-240 V AC/DC, width: 90 mm, integral sc …
-
PNOZ XV2.1P 30/24-240VACDC 2n/o 2n/o t
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 2 N/O, 2 N/O (t = 0 - 30; s). Automatic/monitored start UB 24 - 240 …
-
PNOZ XV2.1P C 3/24-240VACDC 2n/o 2n/o t
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 2 N/O, 2 N/O (t = 0 - 3 s); . Automatic/monitored start UB 24 - 240 …
-
PNOZ X9 100-120VAC 24VDC 7n/o 2n/c 2so
Safety relay (standalone) Inputs: 1- / 2-channel wiring with detection; of shorts across contacts Outputs: 7 N/O, 2 N/C, 2 semiconductor.; Automatic/monitored start UB 100 - 120 V …
-
PNOZ X9 200-230VAC 24VDC 7n/o 2n/c 2so
Safety relay (standalone), inputs: 1/2-channel wiring; with/without detection of shorts across contacts, outputs: 7 N/O, 2 N/C,2 SC; automatic/manual/monitored start and automatic …
-
PNOZ XV2.1P 300/24-240VACDC 2n/o 2n/o t
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 2 N/O, 2 N/O (t = 0 - 300; s). Automatic/monitored start UB 24 - 24 …
-
PNOZ XV2.1P C 300/24-240VACDC 2n/o 2n/o
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 2 N/O, 2 N/O (t = 0 - 300; s). Automatic/monitored start UB 24 - 24 …
-
PNOZ XV3.1 3/24-240VACDC 3no 1nc 2no t
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 3 N/O, 1 N/C, 2 N/O; delayed UB 24-240 V AC/DC, width: 90 mm, integ …
-
PNOZ X9P 24DC 24-240VACDC 7no 2nc 2so
Safety relay (standalone), inputs: 1/2-channel wiring; with/without detection of shorts across contacts, outputs: 7 N/O, 2 N/C,2 SC; automatic/monitored start, UB 24 - 240 V AC/DC, …
-
PNOZ XV3.1 30/24-240VACDC 3no 1nc 2no t
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 3 N/O, 1 N/C, 2 N/O; delayed UB 24-240 V AC/DC, width: 90 mm, integ …
-
PNOZ XV3.1P 3/24-240VACDC 3no 1nc 2no t
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 3 N/O, 1 N/C, 2 N/O (t =; 0 - 30 s). Automatic/monitored start UB 2 …
-
PNOZ XV3.1P C 3/24-240VACDC 3no 1nc 2no
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 3 N/O, 1 N/C, 2 N/O (t =; 0 - 3 s). Automatic/monitored start UB 24 …
-
PNOZ X11P 110-120VAC 24VDC 7n/o 1n/c 2so
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts. Outputs: 7 N/O, 1 N/C, 2; semiconductor. Automatic/monitored start UB 110 - …
-
PNOZ X11P 230-240VAC 24VDC 7n/o 1n/c 2so
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts. Outputs: 7 N/O, 1 N/C, 2; semiconductor. Automatic/monitored start UB 230 - …
-
PNOZ X9P C 24DC 24-240VACDC 7no 2nc 2so
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 7 N/O, 2 N/C, 2; semiconductor. Automatic/monitored start UB 24 V D …
-
PNOZ XV3.1 300/24-240VACDC 3no 1nc 2no t
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 3 N/O, 1 N/C, 2 N/O; delayed UB 24 - 240 V AC/DC, width: 90 mm, int …
-
PNOZ XV3.1P 300/24-240VACDC 3no 1nc 2no
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 3 N/O, 1 N/C, 2 N/O (t =; 0 - 300 s). Automatic/monitored start UB …
-
PNOZ XV3.1P 30/24-240VACDC 3no 1nc 2no t
Safety relay (standalone) Inputs: 1-/2-channel wiring with/without; detection of shorts across contacts Outputs: 3 N/O, 1 N/C, 2 N/O (t =; 0 - 30 s). Automatic/monitored start UB 2 …
-
PNOZ XV3.1P C 30/24-240VACDC 3no 1nc 2no
Safety relay (standalone), inputs: 1/2-channel wiring; with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,2 N/O (t = 0 - 30 s),; automatic/monitored start, UB …
-
-
-
-
-
-