Murrelektronik I/O-Systems / MASI67 Page 1 ⍾ Murrelektronik ⍾ Last modified
The Murrelektronik MASI67 product line offers a range of accessories, installation technology, and I/O modules designed for AS-Interface applications. Products typically operate on a bus voltage of 26.5...31.6 V DC and feature DIN-rail or screw mounting options. Many models incorporate M12 connectors and offer addressable functionality within a range of 1...62.
MASI67 / I/O-Systems ⍾ Page 1
-
55033
MASI67 INSTALLATION TECHNOLOGY; Operating voltage : max. 36 V DC; Total current : max. 8 A; Test isolation voltage : AS-Interface/Power 200 V, (EN 60664-1); Protection : IP67; Moun …
-
55034
MASI67 INSTALLATION TECHNOLOGY; Operating voltage : max. 36 V DC; Total current : max. 8 A; Test isolation voltage : AS-Interface/Power 200 V, (EN 60664-1); Protection : IP67; Moun …
-
55035
MASI67 INSTALLATION TECHNOLOGY; Operating voltage : max. 36 V DC; Total current : max. 8 A; Test isolation voltage : AS-Interface/Power 200 V, (EN 60664-1); Protection : IP67; Moun …
-
55036
MASI67 INSTALLATION TECHNOLOGY; Operating voltage : max. 36 V DC; Total current : max. 8 A; Test isolation voltage : AS-Interface/Power 200 V, (EN 60664-1); Protection : IP67; Moun …
-
55037
MASI67 INSTALLATION TECHNOLOGY; Operating voltage : max. 36 V DC; Total current : max. 4 A; Test isolation voltage : AS-Interface/Power 200 V, (EN 60664-1); Protection : IP67; Moun …
-
55038
MASI67 INSTALLATION TECHNOLOGY; Operating voltage : max. 36 V DC; Total current : max. 4 A; Mounting method : DIN-rail mountable (EN 60715) or screw fixing; Temperature range : -20 …
-
-
-
-
-
56400
MASI67 I/O MODULE; PIN 2 and PIN 4 of M12 female bridged : yes; Bus voltage (AS-Interface) : 26.5...31.6 V DC; Profile (IO/ID/ID2 code) : S-0.A.0; Addressing : via built-in address …
-
56401
MASI67 I/O MODULE; PIN 2 and PIN 4 of M12 female bridged : no; Bus voltage (AS-Interface) : 26.5...31.6 V DC; Profile (IO/ID/ID2 code) : 2× S-0.A.2; Addressing : via built-in addre …
-
56404
MASI67 I/O MODULE; Bus voltage (AS-Interface) : 26.5...31.6 V DC; Profile (IO/ID/ID2 code) : S-7.F.E; Addressing : via built-in address port or master; Address range : 1...31; Doub …
-
56405
MASI67 I/O MODULE; Total current (AS-Interface) : max. 250 mA; Bus voltage (AS-Interface) : 26.5...31.6 V DC; Profile (IO/ID/ID2 code) : S-0.A.0; Addressing : via built-in address …
-
56406
MASI67 I/O MODULE; Total current (AS-Interface) : max. 290 mA; Bus voltage (AS-Interface) : 26.5...31.6 V DC; Profile (IO/ID/ID2 code) : 2× S-0.A.0; Addressing : via built-in addre …
-
56408
MASI67 I/O MODULE; Total current (AS-Interface) : max. 250 mA; Bus voltage (AS-Interface) : 26.5...31.6 V DC; Profile (IO/ID/ID2 code) : S-7.0.E; Addressing : via built-in address …
-
56412
MASI67 INSTALLATION TECHNOLOGY; Bus voltage (AS-Interface) : 26.5...31.6 V DC; External supply : 1× aux power; Current via M12 port : max. 4 A; Total current : max. 8 A; Protection …
-
56413
MASI67 I/O MODULE; Bus voltage (AS-Interface) : 26.5...31.6 V DC; Profile (IO/ID/ID2 code) : S-0.A.2; Addressing : via built-in address port or master; Y-wiring : yes; Address rang …
-
56414
MASI67 I/O MODULE K3; Bus voltage (AS-Interface) : 26.5...31.6 V DC; Profile (IO/ID/ID2 code) : S-7.A.7; Addressing : via built-in address port or master; Address range : 1...62 (1 …
-
56415
MASI67 I/O MODULE K3; Bus voltage (AS-Interface) : 26.5...31.6 V DC; Profile (IO/ID/ID2 code) : 2× S-7.A.7; Addressing : via built-in address port or master; Address range : 1...62 …
-
56416
MASI67 INSTALLATION TECHNOLOGY; Bus voltage (AS-Interface) : 26.5...31.6 V DC; External supply : 2× separately aux power; Current via M12 port : max. 4 A; Total current : max. 2× 8 …
-
-