Fluid sensors Items 4801 - 4896 of 6009 ⍾ SICK ⍾ Last modified
Fluid sensors ⍾ Page 51
-
-
PFT-SCP315SGDSEAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Compound pressure; Pressure unit: psi; Measuring range: –30 inHg ... 300 psi; Process temperature: –40 °C ... +125 °C; Output sign …
-
PFT-SRB010AG1SEAALSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 10 bar; Process temperature: –40 °C ... +125 °C; Output signal: 4 m …
-
PFT-SRB010AG1SSAALSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 10 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 m …
-
PFT-SRB010AG1SSAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 10 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 m …
-
PFT-SRB010AG1SSAVMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 10 bar; Process temperature: –30 °C ... +100 °C; Output signal: 0 V …
-
PFT-SRB010AG2SSAUMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 10 bar; Process temperature: –30 °C ... +100 °C; Output signal: 0 V …
-
-
PFT-SRB010AGDSSAALSSZ
Pressure transmitter. Measuring range: 0 bar ... 10 bar. Output signal: 4...20 mA. Process connection: G 1/2 B according to EN 837. Connection type: L-connector (DIN EN 175301-803 …
-
-
PFT-SRB010AN1SSAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 10 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 m …
-
PFT-SRB010SG1SEAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 10 bar; Process temperature: –40 °C ... +125 °C; Output signal: 4 m …
-
PFT-SRB010SG1SSAALSSZ
Pressure transmitter. Measuring range: 0 bar ... 10 bar. Output signal: 4...20 mA. Process connection: G 1/4 A according to DIN 3852-E. Connection type: L-connector DIN EN 175301-8 …
-
-
-
-
-
PFT-SRB010SGDSEAA3SSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 10 bar; Process temperature: –40 °C ... +125 °C; Output signal: 4 m …
-
PFT-SRB010SGDSEAALSSZ
Pressure transmitter. Measuring range: 0 bar ... 10 bar. Output signal: 4...20 mA. Process connection: G 1/2 B according to EN 837. Connection type: L-connector (DIN EN 175301-803 …
-
PFT-SRB010SGDSEAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 10 bar; Process temperature: –40 °C ... +125 °C; Output signal: 4 m …
-
PFT-SRB010SGDSSAALSSZ
Pressure transmitter. Measuring range: 0 bar ... 10 bar. Output signal: 4...20 mA. Process connection: G 1/2 B according to EN 837. Connection type: L-connector (DIN EN 175301-803 …
-
PFT-SRB010SGDSSAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 10 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 m …
-
PFT-SRB010SM2SEAALSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 10 bar; Process temperature: –40 °C ... +125 °C; Output signal: 4 m …
-
PFT-SRB010SN1SSAALSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 10 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 m …
-
PFT-SRB010SN1SSAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 10 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 m …
-
PFT-SRB016AG1SSAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 16 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 m …
-
PFT-SRB016AGDSEAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 16 bar; Process temperature: –40 °C ... +125 °C; Output signal: 4 m …
-
PFT-SRB016SG1SEAU1SSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 16 bar; Process temperature: –40 °C ... +125 °C; Output signal: 0 V …
-
PFT-SRB016SG1SSAA5SSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 16 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 m …
-
PFT-SRB016SGDSEAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 16 bar; Process temperature: –40 °C ... +125 °C; Output signal: 4 m …
-
PFT-SRB016SGDSEAVMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 16 bar; Process temperature: –40 °C ... +125 °C; Output signal: 0 V …
-
PFT-SRB016SGDSSAALSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 16 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 m …
-
PFT-SRB016SGDSSAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 16 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 m …
-
PFT-SRB016SGDSSAVLSSZ
Pressure transmitter. Measuring range: 0 bar ... 16 bar. Output signal: 0...10 V, 3-wire. Process connection: G 1/2 B according to EN 837. Connection type: L-connector (DIN EN 1753 …
-
-
PFT-SRB016SN1SSAALSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 16 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 m …
-
PFT-SRB025AG2SSAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 25 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 m …
-
PFT-SRB025AN1SEAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 25 bar; Process temperature: –40 °C ... +125 °C; Output signal: 4 m …
-
-
PFT-SRB025SG1SSAALSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 25 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 m …
-
-
-
-
-
PFT-SRB025SGDSSAALSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 25 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 m …
-
PFT-SRB025SGDSSAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 25 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 m …
-
PFT-SRB025SGDSSAVLSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 25 bar; Process temperature: –30 °C ... +100 °C; Output signal: 0 V …
-
-
PFT-SRB025SN1SEAUMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 25 bar; Process temperature: –40 °C ... +125 °C; Output signal: 0 V …
-
PFT-SRB040AG1MSAULSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 40 bar; Process temperature: –30 °C ... +100 °C; Output signal: 0 V …
-
PFT-SRB040AG1SEAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 40 bar; Process temperature: –40 °C ... +125 °C; Output signal: 4 m …
-
-
PFT-SRB040AR1SSAV3SSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 40 bar; Process temperature: –30 °C ... +100 °C; Output signal: 0 V …
-
-
-
-
-
-
-
PFT-SRB040SGDSEAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 40 bar; Process temperature: –40 °C ... +125 °C; Output signal: 4 m …
-
PFT-SRB040SGDSSAALSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 40 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 m …
-
PFT-SRB040SN1SSAVMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 40 bar; Process temperature: –30 °C ... +100 °C; Output signal: 0 V …
-
PFT-SRB060AG1MSAULSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 60 bar; Process temperature: –30 °C ... +100 °C; Output signal: 0 V …
-
PFT-SRB060AG1NSAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 60 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 m …
-
PFT-SRB060AGDSEAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 60 bar; Process temperature: –40 °C ... +125 °C; Output signal: 4 m …
-
PFT-SRB060AGDSSAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 60 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 m …
-
PFT-SRB060SG1SEAALSSF
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 60 bar; Process temperature: –40 °C ... +125 °C; Output signal: 4 m …
-
PFT-SRB060SG1SEAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 60 bar; Process temperature: –40 °C ... +125 °C; Output signal: 4 m …
-
PFT-SRB060SG1SSAALSSZ
Pressure transmitter. Measuring range: 0 bar ... 60 bar. Output signal: 4...20 mA. Process connection: G 1/4 A according to DIN 3852-E. Connection type: L-connector (DIN EN 175301- …
-
-
PFT-SRB060SG1SSAVLSSZ
Pressure transmitter. Measuring range: 0 bar ... 60 bar. Output signal: 0...10 V, 3-wire. Process connection: G 1/4 A according to DIN 3852-E. Connection type: L-connector (DIN EN …
-
PFT-SRB060SG1SSAVMSSZ
Pressure transmitter. Measuring range: 0 bar ... 60 bar. Output signal: 0...10 V, 3-wire. Process connection: G 1/4 A according to DIN 3852-E. Connection type: M12 x 1, 4-pin, IP 6 …
-
PFT-SRB060SG2SSAVMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 60 bar; Process temperature: –30 °C ... +100 °C; Output signal: 0 V …
-
-
PFT-SRB100AN1SSAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 100 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 …
-
PFT-SRB100SG1MSAVMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 100 bar; Process temperature: –30 °C ... +100 °C; Output signal: 0 …
-
PFT-SRB100SG1NSAVMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 100 bar; Process temperature: –30 °C ... +100 °C; Output signal: 0 …
-
PFT-SRB100SG1SEAALSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 100 bar; Process temperature: –40 °C ... +125 °C; Output signal: 4 …
-
PFT-SRB100SG1SEAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 100 bar; Process temperature: –40 °C ... +125 °C; Output signal: 4 …
-
PFT-SRB100SG1SSAALSSZ
Pressure transmitter. Measuring range: 0 bar ... 100 bar. Output signal: 4...20 mA. Process connection: G 1/4 A according to DIN 3852-E. Connection type: L-connector (DIN EN 175301 …
-
-
PFT-SRB100SG1SSAVLSSZ
Pressure transmitter. Measuring range: 0 bar ... 100 bar. Output signal: 0...10 V, 3-wire. Process connection: G 1/4 A according to DIN 3852-E. Connection type: L-connector (DIN EN …
-
-
PFT-SRB100SG2SSAALSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 100 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 …
-
-
-
PFT-SRB100SGDSSAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 100 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 …
-
PFT-SRB100SM2SSAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 100 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 …
-
PFT-SRB160AG2SEAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 160 bar; Process temperature: –40 °C ... +125 °C; Output signal: 4 …
-
PFT-SRB160SG1SSAVMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 160 bar; Process temperature: –30 °C ... +100 °C; Output signal: 0 …
-
PFT-SRB160SG2SSAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 160 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 …
-
PFT-SRB160SGDSSAALSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 160 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 …
-
PFT-SRB160SGDSSAVMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 160 bar; Process temperature: –30 °C ... +100 °C; Output signal: 0 …
-
PFT-SRB1X0AG1SSAA5SSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 1 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 mA …
-
PFT-SRB1X0AG1SSAAMSSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 1 bar; Process temperature: –30 °C ... +100 °C; Output signal: 4 mA …
-
PFT-SRB1X0AG1SSAU3SSZ
Features: Medium: Liquid, gaseous; Pressure type: Gauge pressure; Pressure unit: bar; Measuring range: 0 bar ... 1 bar; Process temperature: –30 °C ... +100 °C; Output signal: 0 V …