Turck Flow sensors / FCI Page 1 ⍾ Turck ⍾ Last modified
The Turck Flow sensors / FCI product line consists of inline flow sensors utilizing a calorimetric principle for flow measurement. These sensors feature integrated or separate processors, allowing for adjustment via potentiometer and status indication via LED bands. They are designed for both liquid and gaseous media and offer various output options including transistor, PNP, relay, and 4...20 mA analog signals. Some models are ATEX certified for use in hazardous environments.
FCI / Flow sensors ⍾ Page 1
-
FCI-D03A4P-NA
Flow sensor, inline sensor with separate processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer on processor. Status indicated via LED chain …
-
FCI-D04A4P-NA-H1141
Flow sensor, inline sensor with separate processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer on processor. Status indicated via LED chain …
-
FCI-D10A4P-NA-H1141
Flow sensor, inline sensor with separate processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer on processor. Status indicated via LED chain …
-
FCI-D04A4P-ARX-H1140
Flow sensor, inline sensor with integrated processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 0.01...1 l/min. …
-
FCI-D04A4P-LIX-H1141
Flow sensor, inline sensor with integrated processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 0.01...1 l/min. …
-
FCI-D06CTP-ARX-H1140
Flow sensor, inline sensor with integrated processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 0.02...3 l/min. …
-
FCI-D06CTP-LIX-H1141
Flow sensor, inline sensor with integrated processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 0.02...3 l/min. …
-
FCI-D10A4P-ARX-H1140
Flow sensor, inline sensor with integrated processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 0.1...6 l/min. 4 …
-
FCI-D10A4P-LIX-H1141
Flow sensor, inline sensor with integrated processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 0.1...6 l/min. 3 …
-
FCI-D15A4P-ARX-H1140
Flow sensor, inline sensor with integrated processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 3...20 l/min. 4- …
-
FCI-D15A4P-LIX-H1141
Flow sensor, inline sensor with integrated processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 3...20 l/min. 3- …
-
FCI-D20A4P-ARX-H1140
Flow sensor, inline sensor with integrated processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 4...30 l/min. 4- …
-
FCI-D20A4P-LIX-H1141
Flow sensor, inline sensor with integrated processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 4...30 l/min. 3- …
-
FCI-D04A4P-AP8X-H1141
Flow sensor, inline sensor with integrated processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 0.01...1 l/min. …
-
FCI-D06CTP-AP8X-H1141
Flow sensor, inline sensor with integrated processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 0.02...3 l/min. …
-
FCI-D10A4P-AP8X-H1141
Flow sensor, inline sensor with integrated processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 0.1...6 l/min. 3 …
-
FCI-D10A4P-ARX-H1140/A
Flow sensor, inline sensor with integrated processor. Flow sensor for gaseous media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 0.5...40 m/s. 4 …
-
FCI-D10A4P-LIX-H1141/A
Flow sensor, inline sensor with integrated processor. Flow sensor for gaseous media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 0.5...40 m/s. 3 …
-
FCI-D15A4P-AP8X-H1141
Flow sensor, inline sensor with integrated processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 3...20 l/min. 3- …
-
FCI-D20A4P-AP8X-H1141
Flow sensor, inline sensor with integrated processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 4...30 l/min. 3- …
-
FCI-34D10A4P-ARX-H1140
Flow sensor, inline sensor with integrated processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 0.1...6 l/min. S …
-
FCI-34D10A4P-LIX-H1141
Flow sensor, inline sensor with integrated processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 0.1...6 l/min. S …
-
FCI-D10A4P-AP8X-H1141/A
Flow sensor, inline sensor with integrated processor. Flow sensor for gaseous media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 0.5...40 m/s. 3 …
-
FCI-TCD04A4P-ARX-H1140
Flow sensor, inline sensor with integrated processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 1...200 ml/min. …
-
FCI-TCD04A4P-LIX-H1141
Flow sensor, inline sensor with integrated processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 1...200 ml/min. …
-
FCI-34D10A4P-AP8X-H1141
Flow sensor, inline sensor with integrated processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 0.1...6 l/min. S …
-
FCI-D03A4-NAEX-H1141/M12
Flow sensor, inline sensor with separate processor. ATEX category II 2 G, Ex Zone 1. Intrinsically safe flow sensor for liquid media. Calorimetric principle. Adjustment via potenti …
-
FCI-D03A4-NAEX-H1141/M16
Flow sensor, inline sensor with separate processor. ATEX category II 2 G, Ex Zone 1. Intrinsically safe flow sensor for liquid media. Calorimetric principle. Adjustment via potenti …
-
FCI-D09A4-NAEX-H1141/M16
Flow sensor, inline sensor with separate processor. ATEX category II 2 G, Ex Zone 1. Intrinsically safe flow sensor for liquid media. Calorimetric principle. Adjustment via potenti …
-
FCI-TCD04A4P-AP8X-H1141
Flow sensor, inline sensor with integrated processor. Flow sensor for liquid media. Calorimetric principle. Adjustment via potentiometer. LED band. Operating range 1...200 ml/min. …
-
FCI-D03A4-NA-H1141/M12
Flow Monitoring; Flow sensor for liquid media; Calorimetric principle; Adjustment via potentiometer on processor; Status indicated via LED chain on signal processor; Connector devi …
-
FCI-D03A4-NA-H1141/M16
Flow Monitoring; Flow sensor for liquid media; Calorimetric principle; Adjustment via potentiometer on processor; Status indicated via LED chain on signal processor; Connector devi …
-
FCI-D09A4-NA-H1141/M16
Flow Monitoring; Flow sensor for liquid media; Calorimetric principle; Adjustment via potentiometer on processor; Status indicated via LED chain on signal processor; Connector devi …
-
FCI-D10A4P-AP8X-H1141/D076
Flow Monitoring; Flow sensor for liquid media; Calorimetric principle; Adjustment via potentiometer; LED band; Operating range 0.1…6 l/min; DC 3-wire, 19.2…28.8 VDC; NO contact, PN …
-
FCI-TCD04A4P-AP8X-H1141/D077
Flow Monitoring; Flow sensor for liquid media; Calorimetric principle; Adjustment via potentiometer; LED band; Operating range 2…20 ml/min; Mechanical Connection: Barrel, 4 mm; DC …
-
FCI-TCD04A4P-AP8X-H1141/D084
Flow Monitoring; Flow sensor for liquid media; Calorimetric principle; Adjustment via potentiometer; LED band; Operating range 1…200 ml/min; Mechanical Connection: Tube, 6 mm, to c …
-
-
-
-
-
-
-