INT TECHNICS Industrial Automation Partner
  • About us
  • Select brand
    ABB BANNER Baumer BECKHOFF Danfoss ifm INNOMOTICS Keyence Murrelektronik OBO Omron Pepperl+Fuchs Phoenix Contact PILZ Schneider Electric SICK SIEMENS Telemecanique Turck Weidmüller WEINTEK Yaskawa
  • Contacts
  • English En English
    English Deutsch Español Polski
  • Add to RFQ RFQ
  1. Catalog
  2. SICK
  3. Encoders
Encoders Absolute encoders Incremental encoders Linear encoders Measuring wheel encoders Safety encoders Wire draw encoders Encoder accessories

Encoders Items 6337 - 6432 of 10132 ⍾ SICK ⍾ Last modified Jun 6, 2026

Catalog up Absolute encoders Incremental encoders Linear encoders Measuring wheel encoders Safety encoders Wire draw encoders Encoder accessories

Encoders ⍾ Page 67

  • « Previous page
  • 1
  • 22
  • 43
  • 64
  • 85
  • 106
  • » Next page
  • SICK DFS60E-S4WA01250 (1062158)
    Product details Add to RFQ Add to RFQ

    DFS60E-S4WA01250

    DFS60, Rotary. Electrical interface: 10 V ... 32 V, HTL/Push pull, 0-SET, Connector M23, 12-pin, radial.

  • SICK DFS60E-S4WA02000 (1059684)
    Product details Add to RFQ Add to RFQ

    DFS60E-S4WA02000

    DFS60, Rotary. Electrical interface: 10 V ... 32 V, HTL/Push pull, 0-SET, Connector M23, 12-pin, radial.

  • SICK DFS60E-S4WA02048 (1060162)
    Product details Add to RFQ Add to RFQ

    DFS60E-S4WA02048

    DFS60, Rotary. Electrical interface: 10 V ... 32 V, HTL/Push pull, 0-SET, Connector M23, 12-pin, radial.

  • SICK DFS60E-S4WB01024 (1062134)
    Product details Add to RFQ Add to RFQ

    DFS60E-S4WB01024

    DFS60, Rotary. Electrical interface: 10 V ... 32 V, HTL/Push pull, 0-SET, Connector M23, 12-pin, axial.

  • SICK DFS60E-T5AK02000 (1072006)
    Product details Add to RFQ Add to RFQ

    DFS60E-T5AK02000

    Performance: Pulses per revolution: 2,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfac …

  • SICK DFS60E-T7AK02048 (1085603)
    Product details Add to RFQ Add to RFQ

    DFS60E-T7AK02048

    Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-T7EN01000 (1091447)
    Product details Add to RFQ Add to RFQ

    DFS60E-T7EN01000

    Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfac …

  • SICK DFS60E-T8EM01024 (1069931)
    Product details Add to RFQ Add to RFQ

    DFS60E-T8EM01024

    Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TAEA00200 (1068193)
    Product details Add to RFQ Add to RFQ

    DFS60E-TAEA00200

    Performance: Pulses per revolution: 200 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TAEA01024 (1096116)
    Product details Add to RFQ Add to RFQ

    DFS60E-TAEA01024

    Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TAEC00250 (1073871)
    Product details Add to RFQ Add to RFQ

    DFS60E-TAEC00250

    Performance: Pulses per revolution: 250 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TBAK00100 (1073595)
    Product details Add to RFQ Add to RFQ

    DFS60E-TBAK00100

    Performance: Pulses per revolution: 100 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TBEC02048 (1087376)
    Product details Add to RFQ Add to RFQ

    DFS60E-TBEC02048

    Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TBEL02048 (1078780)
    Product details Add to RFQ Add to RFQ

    DFS60E-TBEL02048

    Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TBEM00720 (1069141)
    Product details Add to RFQ Add to RFQ

    DFS60E-TBEM00720

    Performance: Pulses per revolution: 720 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TCAK02048 (1089855)
    Product details Add to RFQ Add to RFQ

    DFS60E-TCAK02048

    Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TCEM01024 (1081116)
    Product details Add to RFQ Add to RFQ

    DFS60E-TCEM01024

    Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TDAC01024 (1077202)
    Product details Add to RFQ Add to RFQ

    DFS60E-TDAC01024

    Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TDAC02000 (1106640)
    Product details Add to RFQ Add to RFQ

    DFS60E-TDAC02000

    Performance: Pulses per revolution: 2,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfac …

  • SICK DFS60E-TDAC02048 (1067986)
    Product details Add to RFQ Add to RFQ

    DFS60E-TDAC02048

    Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TDAL00200 (1072464)
    Product details Add to RFQ Add to RFQ

    DFS60E-TDAL00200

    Performance: Pulses per revolution: 200 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TDAL01000 (1077017)
    Product details Add to RFQ Add to RFQ

    DFS60E-TDAL01000

    Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfac …

  • SICK DFS60E-TDAN01024 (1067147)
    Product details Add to RFQ Add to RFQ

    DFS60E-TDAN01024

    Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TDCM01024 (1069805)
    Product details Add to RFQ Add to RFQ

    DFS60E-TDCM01024

    Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TDEC00314 (1072238)
    Product details Add to RFQ Add to RFQ

    DFS60E-TDEC00314

    Performance: Pulses per revolution: 314 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TDEC00500 (1076171)
    Product details Add to RFQ Add to RFQ

    DFS60E-TDEC00500

    Performance: Pulses per revolution: 500 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TDEC02000 (1069941)
    Product details Add to RFQ Add to RFQ

    DFS60E-TDEC02000

    Performance: Pulses per revolution: 2,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfac …

  • SICK DFS60E-TDEK00100 (1067516)
    Product details Add to RFQ Add to RFQ

    DFS60E-TDEK00100

    Performance: Pulses per revolution: 100 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TDEL00500 (1086150)
    Product details Add to RFQ Add to RFQ

    DFS60E-TDEL00500

    Performance: Pulses per revolution: 500 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TDEL01000 (1068589)
    Product details Add to RFQ Add to RFQ

    DFS60E-TDEL01000

    Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfac …

  • SICK DFS60E-TDEM02048 (1104064)
    Product details Add to RFQ Add to RFQ

    DFS60E-TDEM02048

    Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TDEN00500 (1051939)
    Product details Add to RFQ Add to RFQ

    DFS60E-TDEN00500

    Performance: Pulses per revolution: 500 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TDEN01024 (1104005)
    Product details Add to RFQ Add to RFQ

    DFS60E-TDEN01024

    Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TEAA02000 (1075696)
    Product details Add to RFQ Add to RFQ

    DFS60E-TEAA02000

    Performance: Pulses per revolution: 2,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfac …

  • SICK DFS60E-TEAK02048 (1077191)
    Product details Add to RFQ Add to RFQ

    DFS60E-TEAK02048

    Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TEAM02048 (1068924)
    Product details Add to RFQ Add to RFQ

    DFS60E-TEAM02048

    Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TECA00100 (1067385)
    Product details Add to RFQ Add to RFQ

    DFS60E-TECA00100

    Performance: Pulses per revolution: 100 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TECA01000 (1074076)
    Product details Add to RFQ Add to RFQ

    DFS60E-TECA01000

    Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfac …

  • SICK DFS60E-TECC01024 (1080819)
    Product details Add to RFQ Add to RFQ

    DFS60E-TECC01024

    Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TECK02048 (1090045)
    Product details Add to RFQ Add to RFQ

    DFS60E-TECK02048

    Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TECL00250 (1071634)
    Product details Add to RFQ Add to RFQ

    DFS60E-TECL00250

    Performance: Pulses per revolution: 250 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TECL01250 (1091276)
    Product details Add to RFQ Add to RFQ

    DFS60E-TECL01250

    Performance: Pulses per revolution: 1,250 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfac …

  • SICK DFS60E-TEEC00S03 (1103158)
    Product details Add to RFQ Add to RFQ

    DFS60E-TEEC00S03

    Features: Special device: ✔; Specialty: Statour coupling (4062430) premounted; Standard reference device: DFS60E-TEEC00360, 1065098; Performance: Pulses per revolution: 360 1); Mea …

  • SICK DFS60E-TEEL00250 (1071398)
    Product details Add to RFQ Add to RFQ

    DFS60E-TEEL00250

    Performance: Pulses per revolution: 250 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TEEL00S02 (1061094)
    Product details Add to RFQ Add to RFQ

    DFS60E-TEEL00S02

    Features: Special device: ✔; Specialty: Stator coupling 2059368 premounted; Standard reference device: DFS60E-TEEL00360, 1054197; Performance: Pulses per revolution: 360 1); Measur …

  • SICK DFS60E-TEEL02048 (1069459)
    Product details Add to RFQ Add to RFQ

    DFS60E-TEEL02048

    Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TEEM00100 (1100124)
    Product details Add to RFQ Add to RFQ

    DFS60E-TEEM00100

    Performance: Pulses per revolution: 100 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TEEM00512 (1067443)
    Product details Add to RFQ Add to RFQ

    DFS60E-TEEM00512

    Performance: Pulses per revolution: 512 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: C …

  • SICK DFS60E-TFEA00100 (1084868)
    Product details Add to RFQ Add to RFQ

    DFS60E-TFEA00100

    Performance: Pulses per revolution: 100 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TFEK00200 (1071481)
    Product details Add to RFQ Add to RFQ

    DFS60E-TFEK00200

    Performance: Pulses per revolution: 200 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TFEM01000 (1088079)
    Product details Add to RFQ Add to RFQ

    DFS60E-TFEM01000

    Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfac …

  • SICK DFS60E-TGAA00S21 (1086360)
    Product details Add to RFQ Add to RFQ

    DFS60E-TGAA00S21

    Features: Special device: ✔; Specialty: BEF-DS02DFS/VFS stator coupling, preassembled with customer-specific orientation in relation to M23 male connector connection; Standard refe …

  • SICK DFS60E-TGAA02048 (1102809)
    Product details Add to RFQ Add to RFQ

    DFS60E-TGAA02048

    Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TGCA00100 (1075493)
    Product details Add to RFQ Add to RFQ

    DFS60E-TGCA00100

    Performance: Pulses per revolution: 100 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TGCA02048 (1070132)
    Product details Add to RFQ Add to RFQ

    DFS60E-TGCA02048

    Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TGCC01000 (1067839)
    Product details Add to RFQ Add to RFQ

    DFS60E-TGCC01000

    Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfac …

  • SICK DFS60E-TGCC01024 (1069263)
    Product details Add to RFQ Add to RFQ

    DFS60E-TGCC01024

    Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TGCK02048 (1084630)
    Product details Add to RFQ Add to RFQ

    DFS60E-TGCK02048

    Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TGCL00100 (1081255)
    Product details Add to RFQ Add to RFQ

    DFS60E-TGCL00100

    Performance: Pulses per revolution: 100 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TGCL01000 (1071576)
    Product details Add to RFQ Add to RFQ

    DFS60E-TGCL01000

    Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfac …

  • SICK DFS60E-TGEA00S08 (1068237)
    Product details Add to RFQ Add to RFQ

    DFS60E-TGEA00S08

    Features: Special device: ✔; Specialty: Customized stator coupling (2047428) premounted; Standard reference device: DFS60E-TGEA01024, 1037732; Performance: Pulses per revolution: 1 …

  • SICK DFS60E-TGEC00200 (1101186)
    Product details Add to RFQ Add to RFQ

    DFS60E-TGEC00200

    Performance: Pulses per revolution: 200 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TGEC01000 (1079212)
    Product details Add to RFQ Add to RFQ

    DFS60E-TGEC01000

    Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfac …

  • SICK DFS60E-TGEK00512 (1073237)
    Product details Add to RFQ Add to RFQ

    DFS60E-TGEK00512

    Performance: Pulses per revolution: 512 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: C …

  • SICK DFS60E-TGEM00100 (1073753)
    Product details Add to RFQ Add to RFQ

    DFS60E-TGEM00100

    Performance: Pulses per revolution: 100 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TGEM00200 (1072399)
    Product details Add to RFQ Add to RFQ

    DFS60E-TGEM00200

    Performance: Pulses per revolution: 200 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TGEN00250 (1063822)
    Product details Add to RFQ Add to RFQ

    DFS60E-TGEN00250

    Performance: Pulses per revolution: 250 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TGEN01000 (1060918)
    Product details Add to RFQ Add to RFQ

    DFS60E-TGEN01000

    The DFS60 incremental encoder, model DFS60E-TGEN01000, features a robust mechanical design with a 14 mm hollow shaft and front clamp. It operates with a communication interface vol …

  • SICK DFS60E-THAA01250 (1073394)
    Product details Add to RFQ Add to RFQ

    DFS60E-THAA01250

    Performance: Pulses per revolution: 1,250 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfac …

  • SICK DFS60E-THAK02000 (1097837)
    Product details Add to RFQ Add to RFQ

    DFS60E-THAK02000

    Performance: Pulses per revolution: 2,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfac …

  • SICK DFS60E-THCC00500 (1075148)
    Product details Add to RFQ Add to RFQ

    DFS60E-THCC00500

    Performance: Pulses per revolution: 500 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-THCK01024 (1070136)
    Product details Add to RFQ Add to RFQ

    DFS60E-THCK01024

    Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-THCL01024 (1095621)
    Product details Add to RFQ Add to RFQ

    DFS60E-THCL01024

    Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-THEC00360 (1069886)
    Product details Add to RFQ Add to RFQ

    DFS60E-THEC00360

    Performance: Pulses per revolution: 360 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-THEM00500 (1079483)
    Product details Add to RFQ Add to RFQ

    DFS60E-THEM00500

    Performance: Pulses per revolution: 500 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TJAA02048 (1076175)
    Product details Add to RFQ Add to RFQ

    DFS60E-TJAA02048

    Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TJAC01024 (1075053)
    Product details Add to RFQ Add to RFQ

    DFS60E-TJAC01024

    Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TJAC02048 (1090118)
    Product details Add to RFQ Add to RFQ

    DFS60E-TJAC02048

    Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TJAK02048 (1089498)
    Product details Add to RFQ Add to RFQ

    DFS60E-TJAK02048

    Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60E-TJEC00360 (1075635)
    Product details Add to RFQ Add to RFQ

    DFS60E-TJEC00360

    Performance: Pulses per revolution: 360 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfaces …

  • SICK DFS60E-TJEC01000 (1069004)
    Product details Add to RFQ Add to RFQ

    DFS60E-TJEC01000

    Performance: Pulses per revolution: 1,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.2°; Error limits: ± 0.3°; Interfac …

  • SICK DFS60E-TJEK01024 (1078041)
    Product details Add to RFQ Add to RFQ

    DFS60E-TJEK01024

    Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.15°; Error limits: ± 0.3°; Interfaces: …

  • SICK DFS60I-BBAK10000 (1093911)
    Product details Add to RFQ Add to RFQ

    DFS60I-BBAK10000

    Performance: Pulses per revolution: 10,000 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± …

  • SICK DFS60I-BBEC00360 (1086932)
    Product details Add to RFQ Add to RFQ

    DFS60I-BBEC00360

    Performance: Pulses per revolution: 360 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0. …

  • SICK DFS60I-BBEC00900 (1086931)
    Product details Add to RFQ Add to RFQ

    DFS60I-BBEC00900

    Performance: Pulses per revolution: 900 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0. …

  • SICK DFS60I-BBEC01800 (1086930)
    Product details Add to RFQ Add to RFQ

    DFS60I-BBEC01800

    Performance: Pulses per revolution: 1,800 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ±  …

  • SICK DFS60I-BBNC01024 (1104088)
    Product details Add to RFQ Add to RFQ

    DFS60I-BBNC01024

    Performance: Periods per revolution: 1,024; Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; …

  • SICK DFS60I-BBPC65536 (1101235)
    Product details Add to RFQ Add to RFQ

    DFS60I-BBPC65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-BDMC65536 (1083941)
    Product details Add to RFQ Add to RFQ

    DFS60I-BDMC65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-BDPC32678 (1102681)
    Product details Add to RFQ Add to RFQ

    DFS60I-BDPC32678

    Performance: Pulses per revolution: 32,678 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± …

  • SICK DFS60I-BDPC65536 (1083944)
    Product details Add to RFQ Add to RFQ

    DFS60I-BDPC65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-BDPK65536 (1083943)
    Product details Add to RFQ Add to RFQ

    DFS60I-BDPK65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-BDPM65536 (1083942)
    Product details Add to RFQ Add to RFQ

    DFS60I-BDPM65536

    Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0. …

  • SICK DFS60I-BEEC00200 (1101452)
    Product details Add to RFQ Add to RFQ

    DFS60I-BEEC00200

    Performance: Pulses per revolution: 200 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0. …

  • SICK DFS60I-BEEC02048 (1104602)
    Product details Add to RFQ Add to RFQ

    DFS60I-BEEC02048

    Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03 …

  • SICK DFS60I-BEEC02500 (1082517)
    Product details Add to RFQ Add to RFQ

    DFS60I-BEEC02500

    Performance: Pulses per revolution: 2,500 1); Measuring step: 90° electric/pulses per revolution; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ±  …

« Prev page Next page »

SICK ⍾ Recently updated

MRA-F080-102D2 MICS3-AAAZ55AZ1P01 KTX-WP92141252ZZZZ KTX-WB9214225AZZZZ DOL-1204-G02MNI BEF-AP8-MPB YM2D24-C50PN1MRJA4 YG2A14-100VB3XLEAX YF8U14-100VA3XLEAX YF8U13-050VA1XLEAX
  • Home
  • About us
  • Privacy policy
  • Select brand
    ABB BANNER Baumer BECKHOFF Danfoss ifm INNOMOTICS Keyence Murrelektronik OBO Omron Pepperl+Fuchs Phoenix Contact PILZ Schneider Electric SICK SIEMENS Telemecanique Turck Weidmüller WEINTEK Yaskawa
  • Contacts
  • English en English
    English Deutsch Español Polski
  • Add to RFQ RFQ

© INT TECHNICS Sp. z o.o.

Żadna z przedstawionych w serwisie stron nie jest ofertą w rozumieniu Kodeksu Cywilnego. Jeśli w opisie prezentowanego produktu występuje cena, ma ona wyłącznie charakter orientacyjny. Loga i nazwy firm są własnością ich prawnych właścicieli i zostały użyte tylko w celach informacyjnych.

Spam kieruj na oumuamua@int-technics.pl