Encoders ⍾ Page 44
-
DFS60A-S4AL08192
Performance: Pulses per revolution: 8,192 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interface …
-
-
-
-
-
-
-
DFS60A-S4AM50000
Performance: Pulses per revolution: 50,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± 0.03°; Inte …
-
DFS60A-S4AM65000
Performance: Pulses per revolution: 65,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± 0.03°; Inte …
-
-
DFS60A-S4AN65536
Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0.03°; Interfa …
-
DFS60A-S4CA02048
Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interface …
-
-
-
-
-
-
DFS60A-S4CA50000
Performance: Pulses per revolution: 50,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± 0.03°; Inte …
-
-
-
-
-
DFS60A-S4CK00256
Performance: Pulses per revolution: 256 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfaces: …
-
-
-
-
-
DFS60A-S4CL20480
Performance: Pulses per revolution: 20,480 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± 0.03°; Inte …
-
-
-
DFS60A-S4CM20000
Performance: Pulses per revolution: 20,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± 0.03°; Inte …
-
-
-
DFS60A-S4CZ00S86
Features: Special device: ✔; Specialty: Shaft 10 x 19 mm roundFace mount flange with M3 & M4 (details in dimensional drawing)Male connector, M23, 12-pin, radial, customized PIN as …
-
DFS60A-S4EA00180
Performance: Pulses per revolution: 180 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfa …
-
-
-
DFS60A-S4EA02048
Performance: Pulses per revolution: 2,048 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interface …
-
-
-
-
-
DFS60A-S4EA20000
Performance: Pulses per revolution: 20,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± 0.03°; Inte …
-
-
DFS60A-S4EA60000
Performance: Pulses per revolution: 60,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± 0.03°; Inte …
-
-
DFS60A-S4EC00720
Performance: Pulses per revolution: 720 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfa …
-
-
DFS60A-S4EC01024
Performance: Pulses per revolution: 1,024 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interface …
-
-
-
DFS60A-S4EC30000
Performance: Pulses per revolution: 30,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± 0.03°; Inte …
-
-
-
-
DFS60A-S4EK10362
Performance: Pulses per revolution: 10,362 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± 0.03°; Inte …
-
DFS60A-S4EK10833
Performance: Pulses per revolution: 10,833 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± 0.03°; Inte …
-
-
-
-
-
DFS60A-S4EL20000
Performance: Pulses per revolution: 20,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± 0.03°; Inte …
-
DFS60A-S4EL36000
Performance: Pulses per revolution: 36,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± 0.03°; Inte …
-
-
-
DFS60A-S4EM65536
Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0.03°; Interfa …
-
-
-
DFS60A-S4PB65536
Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0.03°; Interfa …
-
DFS60A-S4PC00S81
Features: Special device: ✔; Specialty: 5000 lines - HTL pre-programmed; Standard reference device: DFS60A-S4PC65536, 1036726; Performance: Pulses per revolution: 65,536 1); Measur …
-
DFS60A-S4PC00S82
Features: Special device: ✔; Specialty: 3000 lines - TTL - pre-programmed; Standard reference device: DFS60A-S4PC65536, 1036726; Performance: Pulses per revolution: 65,536 1); Mea …
-
DFS60A-S4PC65536
Incremental encoders DFS60/DFS60A-S4PC65536 feature a solid shaft face mount flange (10 mm x 19 mm with flat) and support a 4.5 V to 32 V communication interface with TTL/HTL progr …
-
DFS60A-S4PD65536
Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0.03°; Interfa …
-
DFS60A-S4PK02048
The DFS60 incremental encoder, model DFS60A-S4PK02048, features a robust solid shaft face mount flange design (10 mm x 19 mm). It offers flexible communication interfaces, supporti …
-
-
-
DFS60A-S4PL08192
Performance: Pulses per revolution: 8,192 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interface …
-
-
-
DFS60A-S4UA10000
Performance: Pulses per revolution: 10,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0.03°; Inte …
-
DFS60A-S4UA20000
Performance: Pulses per revolution: 20,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± 0.03°; Inte …
-
-
DFS60A-S4VA16384
Performance: Pulses per revolution: 16,384 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0.03°; Interfa …
-
DFS60A-S4VA65536
Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0.03°; Interfa …
-
DFS60A-S4WA00180
Performance: Pulses per revolution: 180 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0.03°; Interfa …
-
DFS60A-SZAC00S08
Features: Special device: ✔; Specialty: Shaft sealing: IP67 on the shaftFace mount flange, solid shaft Ø 10 x 25 mmStarting torque < 1 Ncm; Standard reference device: DFS60A-S4AC3 …
-
DFS60A-SZCK0-S02
Features: Special device: ✔; Specialty: Solid shaft face mount flange 3/8" x 19 mm; Standard reference device: DFS60A-S4CK16384, 1037600; Performance: Pulses per revolution: 16,384 …
-
DFS60A-T8AK10000
Performance: Pulses per revolution: 10,000 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.008°; Error limits: ± 0.03°; Inte …
-
DFS60A-TAEL28672
Performance: Pulses per revolution: 28,672 1); Measuring step: 90° electronically/ppr; Measuring step deviation at non binary number of lines: ± 0.002°; Error limits: ± 0.03°; Inte …
-
-
-
-
-
-
DFS60A-TBMA65536
Performance: Pulses per revolution: 65,536 1); Measuring step: 90° electronically/ppr; Measuring step deviation at binary number of lines: ± 0.0015°; Error limits: ± 0.03°; Interfa …
-