SIEMENS Continuous gas analyzers / 7MB2023 Page 1 ⍾ SIEMENS ⍾ Last modified
The SIEMENS Continuous gas analyzers / 7MB2023 catalog features ULTRAMAT/OXYMAT 6 gas analyzers, designed as 19" rack units for cabinet installation. These analyzers are configured for the combined measurement of infrared-absorbing gases and oxygen, utilizing a non-flow-type compensation branch constructed from stainless steel. They typically include a 6 mm outer diameter pipe and operate with a 5% reference gas pressure of 3000 hPa, although some models utilize an external pump with a pressure of 100 hPa.
7MB2023 / Continuous gas analyzers ⍾ Page 1
-
7MB2023-0AA00-1CE1
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 0.5% reference gas pres …
-
7MB2023-0CB40-0NR1
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 2% reference gas pressu …
-
7MB2023-0EA00-0AJ1
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressu …
-
7MB2023-0EA00-0AM1
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressu …
-
7MB2023-0EA00-1AD1
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressu …
-
7MB2023-0EA00-1AM1
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressu …
-
7MB2023-0EA00-1AP1
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressu …
-
7MB2023-0EA00-1DM1
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressu …
-
7MB2023-0EA00-1NR1
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressu …
-
7MB2023-0EA23-1CR1
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressu …
-
7MB2023-0EB40-1NR1
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressu …
-
7MB2023-0EB47-1NR1
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressu …
-
7MB2023-1AA00-0CR1
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 1/4" outer diameter 0.5% reference gas pres …
-
7MB2023-1EA20-0AF1
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 1/4" outer diameter 5% reference gas pressu …
-
7MB2023-0EA00-1AM1-Z Y11
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressu …
-
7MB2023-0EA00-1NR1-Z A26
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressu …
-
7MB2023-0EA07-1NH1-Z Y11
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressu …
-
7MB2023-0FA20-1NE1-Z Y17
ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressu …
-
7MB2023-1DA43-0PF1-Z Y17
Ultramat/OXYMAT 6 gas analyzer 19"" unit for installation in cabinets pressure equipment directive f. gas 1/liquids 1 art. 3.3 sep Gas connection for sample gas and reference gas, …
-
7MB2023-0AA13-1ND1-Z Y12
+Y17 ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 0.5% reference gas pres …
-
7MB2023-0EA00-1NE1-Z A26
+Y11 ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressu …
-
7MB2023-0EA00-1NR1-Z A26
+Y11 ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressu …
-
7MB2023-0EA23-1ND1-Z Y12
+Y17 ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressu …
-
-
7MB2023-0FA21-1ND1-Z Y12
+Y17 ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressu …
-
7MB2023-0EA83-1NG2-Z A26
+B01 +B04 ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressu …
-
7MB2023-0EA83-1NP3-Z A26
+B01 +B04 ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 6 mm outer diameter 5% reference gas pressu …
-
7MB2023-1AA00-1CB1-Z A26
+A31 +Y11 ULTRAMAT/OXYMAT 6 gas analyzer, 19" rack unit for installation in cabinets for combined measurement of IR absorbing gas and O2 Pipe with 1/4" outer diameter 0.5% reference gas pres …