SIEMENS 3WL Circuit breakers Items 577 - 672 of 2388 ⍾ SIEMENS ⍾ Last modified
The Siemens 3WL circuit breakers catalog offers a range of fixed-mounted and withdrawable circuit breakers designed for various applications. These breakers are available in 3-pole and 4-pole configurations, with sizes ranging from I to III, and are rated for voltages up to 690V and currents from 800A to 4000A. They feature various connection options, including front and rear connections, and are compatible with different operating mechanisms and protective releases.
3WL Circuit breakers ⍾ Page 7
-
3WL1112-4CB35-4AN2-Z C22
+K07 Withdrawable circuit breaker without guide frame 3-pole, size I, IEC In=1250A to 690V, AC50/60Hz Icu=85kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protecti …
-
3WL1112-4CB36-1AA2-Z P23
+R21 +T40 Withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1250A to 690V, AC50/60Hz Icu=85kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection …
-
3WL1112-4CB36-1GA2-Z C26
+K07 +R10 +R15 +R21 Withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1250A to 690V, AC50/60Hz Icu=85kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection …
-
3WL1112-4CB62-1AJ2-Z F40
+T40 Fixed-mounted circuit breaker 3-pole, Size 1, IEC In=1250 A up to 690 V, 50/60 Hz AC Icu=85 kA at 500 V Rear horizontal connection Overcurrent release ETU 25 LSI protection adjusta …
-
3WL1112-4CB62-1FA2-Z A05
Fixed-mounted circuit breaker 3-pole, Size 1, IEC In=1250 A up to 690 V, 50/60 Hz AC Icu=85 kA at 500 V Rear horizontal connection Overcurrent release ETU 25 LSI protection adjusta …
-
3WL1112-4CB68-1GN2-Z A08
+K07 +R15 +R21 +T40 Draw-out circuit breaker with slide-in module frame 3-pole, Size 1, IEC In=1250 A up to 690 V, 50/60 Hz AC Icu=85 kA at 500 V with connecting flange Overcurrent release ETU 25 LSI …
-
3WL1112-4DG66-5FA4-Z C22
+K07 +R16 +R21 Draw-out circuit breaker with slide-in module frame 3-pole, Size 1, IEC In=1250 A up to 690 V, 50/60 Hz AC Icu=85 kA at 500 V Rear horizontal connection Overcurrent release ETU 27 …
-
3WL1112-4DG76-1AA2
Draw-out circuit breaker with slide-in module frame 4-pole, Size 1, IEC In=1250 A up to 690 V, 50/60 Hz AC Icu=85 kA at 500 V Rear horizontal connection Overcurrent release ETU 27 …
-
3WL1112-4EB34-1AN2-Z T40
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=85KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE ELECTRONIC TRIP UNIT ETU 45 LSIN PROT. ADJUST.B. 0.4-1 …
-
3WL1112-4EB65-4GS4
Draw-out circuit breaker Without guide frame 3-pole, Size 1, IEC In=1250 A up to 690 V, 50/60 Hz AC Icu=85 kA at 500 V Rear horizontal connection Overcurrent release ETU 45 LSIN pr …
-
3WL1112-4EB68-1AA2-Z F12
+F36 +R21 Draw-out circuit breaker with slide-in module frame 3-pole, Size 1, IEC In=1250 A up to 690 V, 50/60 Hz AC Icu=85 kA at 500 V with connecting flange Overcurrent release ETU 45 LSIN …
-
3WL1112-4EB68-4GA2-Z F12
+F36 +R21 Draw-out circuit breaker with slide-in module frame 3-pole, Size 1, IEC In=1250 A up to 690 V, 50/60 Hz AC Icu=85 kA at 500 V with connecting flange Overcurrent release ETU 45 LSIN …
-
3WL1112-4EG38-5FA4-Z C01
+C22 +R10 +R16 +R21 +R30 +R50 +S33 Withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1250A to 690V, AC50/60Hz Icu=85kA at 500V w. connection flange Overcurrent release ETU 45 LSING protection adju …
-
3WL1112-4NG36-4GN4
Withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1250A to 690V, AC50/60Hz Icu=85kA at 500V rear connection horizontal Overcurrent release ETU 76 LSING protectio …
-
3WL1116-2AA32-1FA2
Fixed-mount non-aut. circuit-b. 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal without overcurrent release With manual operating mechan …
-
3WL1116-2AA32-4AN2
Fixed-mount non-aut. circuit-b. 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal without overcurrent release Motorized/manual operating m …
-
3WL1116-2AA32-4GN2
Fixed-mount non-aut. circuit-b. 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal without overcurrent release Motorized/manual operating m …
-
3WL1116-2AA34-4GN2
Fixed-mount non-aut. circuit-b. 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V frnt.conn. top/bot. dual-hole without overcurrent release Motorized/manual operatin …
-
3WL1116-2AA35-4GG4
Withdraw. non-aut. circuit-b. without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal without overcurrent release Motorized/ …
-
3WL1116-2AA45-4GA2
Withdraw. non-aut. circuit-b. without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal without overcurrent release Motorized/ …
-
3WL1116-2AA45-4GP2
Withdraw. non-aut. circuit-b. without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal without overcurrent release Motorized/ …
-
3WL1116-2BB32-1AJ2
Fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protection adjustable 0.5-1 …
-
3WL1116-2BB32-1GA2
Fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protection adjustable 0.5-1 …
-
3WL1116-2BB32-4AN2
Fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protection adjustable 0.5-1 …
-
3WL1116-2BB32-4GA2
Fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protection adjustable 0.5-1 …
-
3WL1116-2BB34-4AN2
Fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V frnt.conn. top/bot. dual-hole Overcurrent release ETU 15 LI protection adjustable 0.5 …
-
3WL1116-2BB34-4AN2-Z C22
Fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V frnt.conn. top/bot. dual-hole Overcurrent release ETU 15 LI protection adjustable 0.5 …
-
3WL1116-2BB34-4AN2-Z C22
+F31 Fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V frnt.conn. top/bot. dual-hole Overcurrent release ETU 15 LI protection adjustable 0.5 …
-
3WL1116-2BB35-6BA4-Z A61
+K07 Withdrawable circuit breaker without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protectio …
-
3WL1116-2BB35-6BA4-Z K07
Withdrawable circuit breaker without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protectio …
-
3WL1116-2BB35-6BB4-Z A61
+U01 Withdrawable circuit breaker without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 15 LI protectio …
-
3WL1116-2BB48-5FA2-Z K07
+R15 +T40 Withdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V w. connection flange Overcurrent release ETU 15 LI protection adjusta …
-
3WL1116-2BB62-1AA2
Fixed-mounted circuit breaker 3-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=55 kA at 500 V Rear horizontal connection Overcurrent release ETU 15 LI protection adjustab …
-
3WL1116-2BB62-1GA2
Fixed-mounted circuit breaker 3-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=55 kA at 500 V Rear horizontal connection Overcurrent release ETU 15 LI protection adjustab …
-
3WL1116-2BB62-4GA2
Fixed-mounted circuit breaker 3-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=55 kA at 500 V Rear horizontal connection Overcurrent release ETU 15 LI protection adjustab …
-
3WL1116-2BB62-6BA2
Fixed-mounted circuit breaker 3-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=55 kA at 500 V Rear horizontal connection Overcurrent release ETU 15 LI protection adjustab …
-
3WL1116-2BB63-4AJ2
Fixed-mounted circuit breaker 3-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=55 kA at 500 V Front connection top/bottom Single hole Overcurrent release ETU 15 LI protec …
-
3WL1116-2CB31-4AN2-Z C01
+C22 +K07 +K10 Fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 25 LSI protection adjustable 0.4-1 i …
-
3WL1116-2CB32-1AA2
Fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 …
-
3WL1116-2CB32-4AN2
Fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 …
-
3WL1116-2CB32-4AN2-Z C01
+C22 +K07 +K10 Fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 …
-
3WL1116-2CB32-4AN2-Z C11
+C22 +K07 Fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 …
-
3WL1116-2CB32-4AN2-Z C22
Fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 …
-
3WL1116-2CB32-4AN2-Z S01
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=1600A TO 690V, AC50/60HZ ICU=55KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJUST.B. 0.4-1 IN …
-
3WL1116-2CB32-4GA4-Z K07
Fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 …
-
3WL1116-2CB32-4GN2
Fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 …
-
3WL1116-2CB32-4GS4-Z C11
+C22 +T40 FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=1600A TO 690V, AC50/60HZ ICU=55KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJUST.B. 0.4-1 IN …
-
3WL1116-2CB33-4AM2
Fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V frnt.conn. top/bot. single-hole Overcurrent release ETU 25 LSI protection adjustable …
-
3WL1116-2CB33-4AN2-Z C01
+C22 +K07 +S07 Fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V frnt.conn. top/bot. single-hole Overcurrent release ETU 25 LSI protection adjustable …
-
3WL1116-2CB34-1GN2
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=1600A TO 690V, AC50/60HZ ICU=55KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJUST.B. 0.4-1 …
-
3WL1116-2CB34-4AN2
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=1600A TO 690V, AC50/60HZ ICU=55KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJUST.B. 0.4-1 …
-
3WL1116-2CB34-4AN2-Z C11
+C22 +K07 FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=1600A TO 690V, AC50/60HZ ICU=55KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJUST.B. 0.4-1 …
-
3WL1116-2CB34-4AN2-Z C22
Fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V frnt.conn. top/bot. dual-hole Overcurrent release ETU 25 LSI protection adjustable 0. …
-
3WL1116-2CB34-6AJ2-Z K07
Fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V frnt.conn. top/bot. dual-hole Overcurrent release ETU 25 LSI protection adjustable 0. …
-
3WL1116-2CB35-4AN2
Withdrawable circuit breaker without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protecti …
-
3WL1116-2CB35-4AN2-Z K07
+S01 Withdrawable circuit breaker without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protecti …
-
3WL1116-2CB35-4GN4-Z K07
+R21 +T40 Withdrawable circuit breaker without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protecti …
-
3WL1116-2CB36-1AA2
Withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection …
-
3WL1116-2CB36-1GA2
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE I, IEC IN=1600A TO 690V, AC50/60HZ ICU=55KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJU …
-
3WL1116-2CB36-4AA4
Withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection …
-
3WL1116-2CB36-4AN2-Z C11
+C22 +K07 +P01 +R15 +R21 +T40 Draw-out circuit breaker with slide-in module frame 3-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=55 kA at 500 V Rear horizontal connection Overcurrent release ETU 25 …
-
3WL1116-2CB36-4GA4-Z K07
+R10 +R21 +S07 Withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection …
-
3WL1116-2CB36-4GG4-Z K07
+P61 +R16 +R55 +S07 WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE I, IEC IN=1600A TO 690V, AC50/60HZ ICU=55KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJU …
-
3WL1116-2CB36-4GN4-Z C22
+K07 +S01 Withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection …
-
3WL1116-2CB38-1AA2-Z K07
+R21 WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE I, IEC IN=1600A TO 690V, AC50/60HZ ICU=55KA AT 500V W. CONNECTION FLANGE ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJUST.B. …
-
3WL1116-2CB45-1AA2
Withdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protecti …
-
3WL1116-2CB46-6AN2
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 4-POLE, SIZE I, IEC IN=1600A TO 690V, AC50/60HZ ICU=55KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJU …
-
3WL1116-2CB61-1GA2
Fixed-mounted circuit breaker 3-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=55 kA at 500 V Rear vertical connection Overcurrent release ETU 25 LSI protection adjustabl …
-
3WL1116-2CB62-1AA2
Fixed-mounted circuit breaker 3-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=55 kA at 500 V Rear horizontal connection Overcurrent release ETU 25 LSI protection adjusta …
-
3WL1116-2CB64-1AA2-Z S33
Fixed-mounted circuit breaker 3-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=55 kA at 500 V Front connection top/bottom double hole Overcurrent release ETU 25 LSI prote …
-
3WL1116-2CB65-1AS2-Z C27
+S01 Draw-out circuit breaker Without guide frame 3-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=55 kA at 500 V Rear horizontal connection Overcurrent release ETU 25 LSI pro …
-
3WL1116-2CB66-4GA2-Z K07
+R15 +T40 Draw-out circuit breaker with slide-in module frame 3-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=55 kA at 500 V Rear horizontal connection Overcurrent release ETU 25 …
-
3WL1116-2CB66-4GN4-Z C22
+K07 +S01 Draw-out circuit breaker with slide-in module frame 3-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=55 kA at 500 V Rear horizontal connection Overcurrent release ETU 25 …
-
3WL1116-2CB66-4GS4-Z C22
+K07 +R15 Draw-out circuit breaker with slide-in module frame 3-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=55 kA at 500 V Rear horizontal connection Overcurrent release ETU 25 …
-
3WL1116-2CB68-1AA2-Z K07
Draw-out circuit breaker with slide-in module frame 3-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=55 kA at 500 V with connecting flange Overcurrent release ETU 25 LSI …
-
3WL1116-2CB72-1AA2
Fixed-mounted circuit breaker 4-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=55 kA at 500 V Rear horizontal connection Overcurrent release ETU 25 LSI protection adjusta …
-
3WL1116-2DG32-1AA2
Fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4 …
-
3WL1116-2DG35-1AA2
Withdrawable circuit breaker without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protec …
-
3WL1116-2DG35-1AA2-Z F40
+T40 Withdrawable circuit breaker without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protec …
-
3WL1116-2DG36-1AA2-Z F40
+P18 +R21 +T40 Withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protectio …
-
3WL1116-2DG36-1AA2-Z F40
+T40 Withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protectio …
-
3WL1116-2DG36-1AA2-Z R21
Withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protectio …
-
3WL1116-2DG36-1AA2-Z R21
+T40 Withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protectio …
-
3WL1116-2DG46-4GN2-Z C22
+F23 +K07 +R21 +T40 Withdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protectio …
-
3WL1116-2DG46-4GN2-Z C22
+R21 +R55 +T40 Withdrawable circuit breaker with guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protectio …
-
3WL1116-2DG66-5FF4-Z K07
Draw-out circuit breaker with slide-in module frame 3-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=55 kA at 500 V Rear horizontal connection Overcurrent release ETU 27 …
-
3WL1116-2EB31-1AA2-Z S05
Fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 …
-
3WL1116-2EB32-4GN4-Z T40
Fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protection adjustable 0.4- …
-
3WL1116-2EB35-4GA2
Withdrawable circuit breaker without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protect …
-
3WL1116-2EB38-4GA4-Z C22
+K07 +R10 +R21 +T40 Withdrawable circuit breaker with guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V w. connection flange Overcurrent release ETU 45 LSIN protection adjus …
-
3WL1116-2EB41-1AA2-Z S05
Fixed-mounted circuit breaker 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection vertical Overcurrent release ETU 45 LSIN protection adjustable 0.4-1 …
-
3WL1116-2EB45-5FA2
Withdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSIN protect …
-
3WL1116-2EB62-4GA4-Z F40
+K07 +K13 Fixed-mounted circuit breaker 3-pole, Size 1, IEC In=1600 A up to 690 V, 50/60 Hz AC Icu=55 kA at 500 V Rear horizontal connection Overcurrent release ETU 45 LSIN protection adjust …
-
3WL1116-2EG36-5FA4-Z K07
+R10 +R16 +R21 +S01 WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE I, IEC IN=1600A TO 690V, AC50/60HZ ICU=55KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 45 LSIN PROT ADJU …
-
3WL1116-2EG45-5FM4
Withdrawable circuit breaker without guide frame 4-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=55kA at 500V rear connection horizontal Overcurrent release ETU 45 LSING protec …
-
3WL1116-2FB32-4GA2-Z C22
+K07 +T40 FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=1600A TO 690V, AC50/60HZ ICU=55KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 45 LSIN PROT ADJUST. 0.4-1 IN WIT …