SM2400 ifmSMK21XGXFRKG/US-100

Magnetic-inductive flow meter; Operating voltage [V] : 18...32 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 5; Inputs : counter reset; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; frequency signal; IO-Link; (configurable); Electrical design : PNP/NPN; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max. voltage drop switching output DC [V] : 2; Permanent current rating of switching output DC [mA] : 250; (per output); Number of analogue outputs : 1; Analogue current output [mA] : 4...20; (scalable); Max. load [Ω] : 500; Analogue voltage output [V] : 0...10; (scalable); Min. load resistance [Ω] : 2000; Pulse output : flow rate meter; Short-circuit protection : yes; Type of short-circuit protection : pulsed; Overload protection : yes; Frequency of the output [Hz] : 0.1...10000; Measuring range : 5...600 l/min: 0.3...36 m³/h; Display range : -720...720 l/min: -43.2...43.2 m³/h; Resolution : 0.5 l/min: 0.02 m³/h; Set point SP : 8...600 l/min: 0.5...36 m³/h; Reset point rP : 5...597 l/min: 0.3...35.8 m³/h; Analogue start point ASP : 0...480 l/min: 0...28.8 m³/h; Analogue end point AEP : 120...600 l/min: 7.2...36 m³/h; Low flow cut-off LFC : < 15 l/min: < 0.9 m³/h; In steps of : 0.5 l/min: 0.02 m³/h; Measuring dynamics : 1:120; Pulse value : 0.0001...600 x 10³ m³; In steps of : 0.0001 m³; Pulse length [s] : 0,008...2; Dynamic response T05 / T09 [s] : T09 = 3 (Q > 15 l/min); Response time [s] : 0.35; (dAP = 0); Delay time programmable dS, dr [s] : 0...50; Damping for the switching output dAP [s] : 0...5; Parameter setting options : Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/frequency/pulse output; start-up delay; display can be deactivated; Display unit; empty pipe detection; Communication interface : IO-Link; Transmission type : COM2 (38,4 kBaud); IO-Link revision : 1.1; SDCI standard : IEC 61131-9 CDV; Profiles : Smart Sensor: Process Data Variable; Device Identification; SIO mode : yes; Required master port type : A; Process data analogue : 3; Process data binary : 2; Min. process cycle time [ms] : 5; Supported DeviceIDs : Type of operation: DeviceID | Default: 389; Ambient temperature [°C] : -10...60; Storage temperature [°C] : -25...80; Materials : stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEI; FKM; PBT-GF20; TPE-U; Materials (wetted parts) : stainless steel (1.4404 / 316L); stainless steel (1.4571/316Ti ); PEEK; FKM; Process connection : threaded connection Rc 2 internal thread DN50; Items supplied : Label

Connection
Connector: 1 x M12; Contacts: gold-plated
No. of inputs/outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Current consumption
< 150 mA
Voltage supply
24 V
Display
Display unit: 6 x LED, green (l/min, m³/h, l, m³, 10³, °C) | switching status: 2 x LED, yellow | measured values: alphanumeric display, 4-digit | programming: alphanumeric display, 4-digit
Degree of protection
IP 65; IP 67
Weight
2740 g
Dimensions
Ø 23 / L = 142 mm