3VL3725-2SG36-0AA0 SIEMENS ⍾ 3VL37252SG360AA0
Circuit breaker VL250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU22, LSIG 3 phases/3 lines In=250A, rated current IR=100...250A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection without auxiliary release without auxiliary/alarm switch
- Customs tariff number
- 85362090
- Expected origin
- DE
- Weight
- 2.581 kg
SIEMENS 3VL3725-2SG36-0AA0 Datasheet PDF (en) Size: 179 KB |
Download |
Related in 3vl3725-2s / 3VL3 (200 ... 250 A) ⍾ Page 1
-
3VL3725-2SB36-0AD1
Circuit breaker VL250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU10, LI In=250A, rated current IR=100...250A, overload protection, II …
-
3VL3725-2SE36-0AB1
Circuit breaker VL250H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Trip Unit ETU20, LSI In=250A, rated current IR=100...250A, overload protection, ISD=1.5 to 1 …
-
3VL3725-2SF36-0AB1
Circuit breaker VL250H High switching capacity Icu=70 kA, 415V AC 3-pole, system protection Overcurrent release ETU12, LIG 3 phases/4 cables In=250 A, Rated current Ir=100...250 A, …
-
3VL3725-2SL36-0AB1
Circuit breaker VL250H High switching capacity Icu=70 kA, 415V AC 3-pole, system protection Overcurrent release ETU12, LIG 3 phases/3 cables In=250 A, Rated current Ir=100...250 A, …
-
3VL3725-2SP36-0AB1
Circuit breaker VL250H high breaking capacity Icu=70kA, 415V AC 3-pole, motor/generator prot. Electronic Trip Unit ETU10M, LI In=250A, rated current IR=100...250A, overload protect …
-
3VL3725-2SP36-8RD1
Circuit breaker VL250H high breaking capacity Icu=70kA, 415V AC 3-pole, motor/generator prot. Electronic Trip Unit ETU10M, LI In=250A, rated current IR=100...250A, overload protect …
-
3VL3725-1AA36-0AA0
Circuit breaker VL250N without Electronic Trip Unit standard breaking capacity Icu=55kA/415V AC, 3-pole In=< 250A, rated current with screw terminal connections for switching unit …
-
3VL3725-1AA46-0AA0
Circuit breaker VL250N without Electronic Trip Unit standard breaking capacity Icu=55kA/415V AC, 4-pole In=< 250A, rated current without auxiliary release with screw terminal conne …
-
3VL3725-1AP36-0AB1
CIRCUIT-BREAKER VL 250N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, MOTOR/ GENERATOR PROTECTION OVERCURRENT RELEASE ETU10M, LI IN=250A, RATED CURRENT IR=100-250A, OVER …
-
3VL3725-1DC33-0AA0
Circuit breaker VL250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=250A, rated current IR=200...250A, overload protection, I …
-
3VL3725-1DC33-0AB1
Circuit breaker VL250N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=250A, rated current IR=200...250A, overload protection, I …
-
3VL3725-1DC33-0AD1
CIRCUIT-BREAKER VL 250N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=250A, RATED CURRENT IR=200-250A, OVERLOAD II=1200-2500 …