3VL2716-3SB33-0AD1 SIEMENS ⍾ 3VL27163SB330AD1
Circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU10, LI In=160A, rated current IR=64...160A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO); ;
- Kod taryfy celnej
- 85362010
- Kraj pochodzenia
- DE
- Waga
- 2.400 kg
SIEMENS 3VL2716-3SB33-0AD1 Karta katalogowa PDF (en) Rozmiar: 243 KB |
Pobierz |
Pozostałe z kategorii 3vl2716 / 3VL2 (50 ... 160 A) ⍾ Strona 1
-
3VL2716-1AA33-0AA0
Circuit breaker VL160N without Electronic Trip Unit standard breaking capacity Icu=55kA/415V AC, 3-pole In=< 160A, rated current without auxiliary release with box terminals for sw …
-
3VL2716-1AA36-0AA0
Circuit breaker VL160N without Electronic Trip Unit standard breaking capacity Icu=55kA/415V AC, 3-pole In=< 160A, rated current without auxiliary release with screw terminal conne …
-
3VL2716-1AA43-0AA0
Circuit breaker VL160N without Electronic Trip Unit standard breaking capacity Icu=55kA/415V AC, 4-pole In=< 160A, rated current without auxiliary release with box terminals f. swi …
-
3VL2716-1AA46-0AA0
CIRCUIT-BREAKER VL 160N WITHOUT ELECTRONIC TRIP UNIT STANDARD BREAKING CAPACITY ICU= 55KA / 415 V AC, 4-POLE IN= < 160 A, RATED CURRENT WITHOUT AUXILIARY RELEASE WITH SCREW CONNEC …
-
3VL2716-1AP33-0AB1
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, MOTOR/ GENERATOR PROTECTION OVERCURRENT RELEASE ETU10M, LI IN=160A, RATED CURRENT IR=64-160A, OVERLO …
-
3VL2716-1CN46-0AA0
CIRCUIT-BREAKER VL 160N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION ELECTRONIC TRIP UNIT LCD ETU42, LSIG IN=160A, RATED CURRENT IR=64-160A, OVERLOAD ISD= …
-
3VL2716-1DC33-0AA0
Circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=160A, rated current IR=125...160A, overload protection, II=800...160 …
-
3VL2716-1DC33-0AB1
Circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=160A, rated current IR=125...160A, overload protection, II=800...160 …
-
3VL2716-1DC33-0AD1
WYŁĄCZNIK KOMPAKTOWY VL160 DO OCHRONY INSTALACJI TM, 3-BIEGUNOWY, IN=160A, ICU=55 KA / 415V AC,; WYZWALACZ TERMOMAGNETYCZNY Z FUNKCJAMI OCHRONY LI: IR=0,8...1 x IN, Ii=5...10 x IN, …
-
3VL2716-1DC33-2JB1
CIRCUIT-BREAKER VL 160N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=160A, RATED CURRENT IR=125-160A, OVERLOAD II=800-1600A, …
-
3VL2716-1DC36-0AA0
Circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=160A, rated current IR=125...160A, overload protection, I …
-
3VL2716-1DC36-0AB1
WYŁĄCZNIK KOMPAKTOWY VL160 DO OCHRONY INSTALACJI TM, 3-BIEGUNOWY, IN=160A, ICU=55 KA / 415V AC,; WYZWALACZ TERMOMAGNETYCZNY Z FUNKCJAMI OCHRONY LI: IR=0,8...1 x IN, Ii=5...10 x IN, …