SD5100 ifmSDR14DGXFPKG/US-100

Flow rate meter for gases; Measuring range [m³/h] : 0.08...24.04; Display range [m³/h] : 0...28.84; Resolution [m³/h] : 0.02; Set point SP [m³/h] : 0.22...24.04; Reset point rP [m³/h] : 0.12...23.94; Analogue start point ASP [m³/h] : 0...19.24; Analogue end point AEP [m³/h] : 4.8...24.04; In steps of [m³/h] : 0.02; Measuring range [m³/h] : 0.04...14.36; Display range [m³/h] : 0...17.24; Set point SP [m³/h] : 0.14...14.36; Reset point rP [m³/h] : 0.08...14.3; Analogue start point ASP [m³/h] : 0...11.48; Analogue end point AEP [m³/h] : 2.88...14.36; Measuring range [m³/h] : 0.04...15; Display range [m³/h] : 0...18; Set point SP [m³/h] : 0.14...15; Reset point rP [m³/h] : 0.08...14.94; Analogue start point ASP [m³/h] : 0...12; Analogue end point AEP [m³/h] : 3...15; Operating voltage [V] : 18...30 DC; (according to EN 50178 SELV/PELV); Protection class : III; Reverse polarity protection : yes; Power-on delay time [s] : 1; Total number of outputs : 2; Output signal : switching signal; analogue signal; pulse signal; IO-Link; (configurable); Electrical design : PNP; Number of digital outputs : 2; Output function : normally open / normally closed; (parameterisable); Max. voltage drop switching output DC [V] : 2; Permanent current rating of switching output DC [mA] : 250; (per output); Number of analogue outputs : 1; Analogue current output [mA] : 4...20; (scalable); Max. load [Ω] : 500; Pulse output : consumed quantity meter; Short-circuit protection : yes; Type of short-circuit protection : pulsed; Overload protection : yes; Low flow cut-off LFC [m³/h] : < 0.26; Measuring dynamics : 1:300; Pulse value : 0.001...1 000 000 m³; In steps of : 0.001...1000 m³; Pulse length [s] : 0,062...2; Accuracy [K] : ± 2; (medium flow in the limit area of the flow measurement range); Response time [s] : 0.1; (dAP = 0); Damping for the switching output dAP in steps [s] : 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1; Parameter setting options : Flow monitoring; quantity meter; Preset counter; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; medium selection; Communication interface : IO-Link; Transmission type : COM2 (38,4 kBaud); IO-Link revision : 1.1; SDCI standard : IEC 61131-9; Profiles : Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis; SIO mode : yes; Required master port type : A; Process data analogue : 3; Process data binary : 2; Min. process cycle time [ms] : 4.1; Supported DeviceIDs : Type of operation: DeviceID | Default: 263; Ambient temperature [°C] : 0...60; Storage temperature [°C] : -20...85; Max. relative air humidity [%] : 90; Materials : PBT-GF20; PC; PC; stainless steel (1.4301 / 304); FKM; Materials (wetted parts) : stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM; aluminium anodised; Process connection : threaded connection G 1/4 DN8; Display unit : Nl/min; Nm³/h; Nm³; °C