7MF4433-1CA22-2AC1-Z A01+Y01
SIEMENS ⍾ 7MF44331CA222AC1ZA01Y01
SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: PN 160 (MWP 2320 psi): 1 to 60 mbar (0.4015 to 24.09 inH2O), max. static pressure 160 bar Diaphragm stainless steel parts of measuring cell stainless steel Process connection: 1/4-18 npt mounting thread: 7/16-20 unf Die-cast aluminium housing, process flange bolts stainless steel International design english inscription documentation as cd None explosion protection Electric connection and cable inlet: cable gland 1/2-14 npt without visible digital indicator (digital display hidden, setting: mA) With steel mounting bracket Range (linear characteristic) specify in plain text: Y01:... to ...mBar,kpa,mpa,...
Related in 7mf4433 / Pressure transmiters DSIII ⍾ Page 1
-
7MF4433-1BA02-1AA1
SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: P …
-
7MF4433-1BA02-1AA6
SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: P …
-
7MF4433-1BA02-1AB1
SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: P …
-
7MF4433-1BA02-1AB6
SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEANING SPAN: PN 32 (M …
-
7MF4433-1BA02-1AD6
SITRANS P DS III / P410, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEANING SPAN: P …
-
7MF4433-1BA02-1BA6
SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEANING SPAN: PN 32 (M …
-
7MF4433-1BA02-1BB6
SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: P …
-
7MF4433-1BA02-1NC6
SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEANING SPAN: PN 32 (M …
-
7MF4433-1BA02-2AB0
SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: P …
-
7MF4433-1BA02-2AB1
SITRANS P DS III, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEANING SPAN: PN 32 (M …
-
7MF4433-1BA02-2BB1
SITRANS P DS III / P410, HART, 4-20 MA TRANSMITTER FOR DIFFERENTIAL PRESSURE AND FLOW PN 32/160 GAS 1/LIQUIDS 1 ART. 3.3 SEP MEASURING CELL FILLING SILICONE NORMAL CLEANING SPAN: P …
-
7MF4433-1BA03-1AA6
SITRANS P DS III / P410, HART, 4-20 mA transmitter for differential pressure and flow PN 32/160 gas 1/liquids 1 art. 3.3 sep Measuring cell filling silicone normal cleaning Span: P …