7MF4033-1GA00-2AB7-Z C11+C12+Y15+Y21 SIEMENS7MF40331GA002AB7ZC11C12Y15Y21

SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 4,0 ... 400 bar g (58.0 ... 5802 psi g), overload limit 600 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing International design english inscription and documentation as cd None explosion protection Electric connection and cable inlet: cable gland M20 x 1.5 Housing cover with window (digital indicator visible, customized adjustment supplement Y21 required) Quality inspection certificate (Factory calibration) to IEC 60770-2 Inspection certificate EN 10204-3.1: certificate pressurised parts Stainless steel tag plate (measuring point description) Max.16 character, specify in plain text: Adjustment digital indicator specify plain text Y21: mBar, bar, kpa, mpa,...