7005-15061-0000000 Murrelektronik ⍾ 7005150610000000
ADAPTOR M12 LITE MALE/ M12 LITE FEMALE 4 POLE; Form : 15061; Operating voltage : max. 250 V AC/DC; Rated surge voltage : 2.5 kV; Operating voltage (only UL listed) : max. 30 V AC/DC; Operating current per contact : max. 4 A; Locking of ports : Screw thread (M12×1 mm) recommended torque 0.6 Nm, self-securing; Protection : IP66K, IP67 inserted and tightened (EN 60529); Material : PUR; Locking material : PA; Temperature range : -25...+85 °C; Test isolation voltage : 0.8 kV eff/rms; eClass : 27279218; Packaging unit : 1
- Customs tariff number
- 85366990
- Weight
- 0.018 kg
- EAN
- 4048879446839
Related in Adapter ⍾ Page 1
-
333370
MSBL0-A-U BU.-ST.PIN 2AUF4/4AUF2 ADAPTER; Form : 333370; Operating voltage : max. 24 V AC/DC; Operating current per contact : max. 4 A; Locking of ports : Screw thread (M12×1 mm) r …
-
333576
M12-PANEL FEED THROUGH 5POLE A-COD; Operating voltage : max. 60 V AC/DC; Rated surge voltage : 1.5 kV; Operating current per contact : max. 4 A; Locking of ports : Screw thread (M1 …
-
341230
Adaptor M12 male 5p./M12 female 6p. shield Cube 67; Form : 341230; Operating voltage : max. 30 V AC/DC; Operating current per contact : max. 4 A; Locking of ports : Screw thread (M …
-
55584
PROFIBUS-PLUG-MALE (SUB-D) 180°; Operating voltage : 4.75...5.25 V DC (via the fieldbus device); Terminating resistor : integrated, switchable; Current consumption : max. 12.5 mA; …
-
55585
PROFIBUS-PLUG-MALE (SUB-D) 90°; Operating voltage : 4.75...5.25 V DC (via the fieldbus device); Terminating resistor : integrated, switchable; Current consumption : max. 12.5 mA; T …
-
55586
PROFIBUS-PLUG-MALE (SUB-D) 90° WITH PG; Operating voltage : 4.75...5.25 V DC (via the fieldbus device); Terminating resistor : integrated, switchable; Current consumption : max. 12 …
-
55760
CAN-PLUG-MALE (SUB-D) 90°; Terminating resistor : integrated, switchable; Transfer rate : max. 1 Mbit/s with switchable terminal resistors; Connection cross section : max. 1 mm²; P …
-
55762
PROFIBUS-PLUG-MALE (SUB-D) 90°; Operating voltage : 4.75...5.25 V DC (via the fieldbus device); Terminating resistor : integrated, switchable; Current consumption : max. 12.5 mA; T …
-
7000-15051-0000000
M12-M12 ADAPTER FOR CUBE67+; Form : 15051; Operating voltage : max. 30 V AC/DC; Operating voltage (only UL listed) : max. 30 V AC/DC; Rated surge voltage : 0.8 kV; Operating curren …
-
7000-15061-0000000
ADAPTOR M12 MALE/ M12 FEMALE 4-POL.; Form : 15061; Operating voltage : max. 250 V AC/DC; Operating voltage (only UL listed) : max. 30 V AC/DC; Rated surge voltage : 2.5 kV; Operati …
-
7000-40057-0000000
Adaptor M12 male / M12 male; Form : 40057; Operating voltage : max. 125 V AC/DC; Rated surge voltage : 1.5 kV; Operating current per contact : max. 4 A; No. of poles : 5; Material …
-
7000-41241-0000000
ADAPTOR M12MALE/M12FEMALE FOR DIAGNOSE CUBE67; Form : 41241; Operating voltage : max. 250 V AC/DC; Operating voltage (only UL listed) : 30 V AC/DC; Rated surge voltage : 2.5 kV; Op …