3VL4740-2TN46-0AA0 SIEMENS ⍾ 3VL47402TN460AA0
Circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 4-pole, line protection trip unit ETU12, LIG In=400A, rated current IR=160...400A, overload protection, II=1.25 to 11xIN, short-circuit protection N protected without auxiliary release without auxiliary/alarm switch
- Customs tariff number
- 85362090
- Expected origin
- DE
- Weight
- 7.830 kg
SIEMENS 3VL4740-2TN46-0AA0 Datasheet PDF (en) Size: 207 KB |
Download |
Related in 3vl4740-1 / 3VL4 (200 ... 400 A) ⍾ Page 1
-
3VL4740-1AA36-0AA0
Circuit breaker VL400N without Electronic Trip Unit standard breaking capacity Icu=55kA/415V AC, 3-pole In=< 400A, rated current without auxiliary release with screw terminal conne …
-
3VL4740-1AA46-0AA0
Circuit breaker VL400N without Electronic Trip Unit standard breaking capacity Icu=55kA/415V AC, 4-pole In=< 400A, rated current without auxiliary release with screw terminal conne …
-
3VL4740-1CN46-0AA0
CIRCUIT-BREAKER VL 400N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION ELECTRONIC TRIP UNIT LCD ETU42, LSIG IN=400A, RATED CURRENT IR=160-400A, OVERLOAD IS …
-
3VL4740-1DC36-0AA0
Circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit TM, LI In=400A, rated current IR=320...400A, overload protection, II=2000...40 …
-
3VL4740-1DC36-0AB1
Circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit TM, LI In=400A, rated current IR=320...400A, overload protection, II=2000...40 …
-
3VL4740-1DC36-0AD1
Circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit TM, LI In=400A, rated current IR=320...400A, overload protection, II=2000...40 …
-
3VL4740-1DC36-2HB1
Circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit TM, LI In=400A, rated current IR=320...400A, overload protection, II=2000...40 …
-
3VL4740-1DC36-2HD1
Circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit TM, LI In=400A, rated current IR=320...400A, overload protection, II=2000...40 …
-
3VL4740-1DC36-8TB1
CIRCUIT-BREAKER VL 400N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=400A, RATED CURRENT IR=320-400A, OVERLOAD II=2000-4000A …
-
3VL4740-1DC36-8TD1
Circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection trip unit TM, LI In=400A, rated current IR=320...400A, overload protection, II=2000...40 …
-
3VL4740-1DE36-0AA0
Circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, non-auto. air circ. br. trip unit magnetic In=400A, rated current II=4000A, short-circuit protection wit …
-
3VL4740-1DE36-0AD1
Circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 3-pole, non-auto. air circ. br. trip unit magnetic In=400A, rated current II=4000A, short-circuit protection wit …