3VL1708-1DD33-0AA0 SIEMENS ⍾ 3VL17081DD330AA0
Circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=80A, rated current Ir=63...80A, overload prot. II=1000A, short-circuit prot. without auxiliary release without auxiliary/alarm switch
- Customs tariff number
- 85362090
- Expected origin
- DE
- Weight
- 2.044 kg
SIEMENS 3VL1708-1DD33-0AA0 Datasheet PDF (en) Size: 197 KB |
Download |
Related in 3vl1708 / 3VL1 (16 ... 160 A) ⍾ Page 1
-
-
3VL1708-1DA33-0AA0
Circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=80A, rated current Ir=80A, overload protection II=1000A, short-c …
-
3VL1708-1DA33-8TD1
CIRCUIT-BREAKER VL160X N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=80A, RATED CURRENT IR=80A, OVERLOAD II=1000A, SHORT-CI …
-
3VL1708-1DA36-0AA0
CIRCUIT-BREAKER VL160X N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=80A, RATED CURRENT IR=80A, OVERLOAD II=1000A, SHORT-CI …
-
3VL1708-1DA36-2JB1
Circuit breaker VL160X N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=80 A, Rated current Ir=80A, Overload protection II=1 …
-
3VL1708-1DA36-2RB1
Circuit breaker VL160X N Standard switching capacity Icu=55 kA, 415V AC 3-pole, system protection Overcurrent release TM, LI In=80 A, Rated current Ir=80A, Overload protection II=1 …
-
3VL1708-1DD33-0AB1
CIRCUIT-BREAKER VL160X N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=80A, RATED CURRENT IR=63-80A, OVERLOAD II=1000A, SHORT …
-
3VL1708-1DD33-0AD1
Circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=80A, rated current Ir=63...80A, overload prot. II=1000A, short-c …
-
3VL1708-1DD33-2HB1
Circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=80A, rated current Ir=63...80A, overload prot. II=1000A …
-
3VL1708-1DD36-8RD1
Circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Electronic Trip Unit TM, LI In=80A, rated current Ir=63...80A, overload prot. II=1000A …
-
3VL1708-1EH43-0AA0
Circuit breaker VL160X N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Trip Unit TM, LI In=80A, rated current Ir=80A, overload protection II=1000A, short-c …
-
3VL1708-2DA33-0AD1
Circuit breaker VL160X H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=80A, rated current Ir=80A, overload protection II=1000A, short-circuit …