3VA5225-5EC61-0AA0 SIEMENS ⍾ 3VA52255EC610AA0
Circuit breaker 3VA5 UL Frame 250 breaking capacity class M 35 kA @ 480 V 2-pole, line protection TM230, FTAM, In=250 A overload protection Ir=250 A permanently set short-circuit protection Ii=5...10 x In without connection
SIEMENS 3VA5225-5EC61-0AA0 Datasheet PDF (en) Size: 1.07 MB |
Download |
Related in 3va52 / 3VA4/3VA5 ⍾ Page 1
-
3VA5210-1BB31-0AA0
MOLDED CASE SWITCH 3VA5 UL FRAME 250 MAX SHORT CIRCUIT CURR. RATING 100KA @ 480 V 3-POLE, LINE PROTECTION MCS110, IN=100A WITHOUT OVERLOAD PROTECTION SELF PROTECTION II=16 X IN W/O …
-
3VA5210-1BB61-0AA0
MOLDED CASE SWITCH 3VA5 UL FRAME 250 MAX SHORT CIRCUIT CURR. RATING 100KA @ 480 V 2-POLE, LINE PROTECTION MCS110, IN=100A WITHOUT OVERLOAD PROTECTION SELF PROTECTION II=16 X IN W/O …
-
3VA5210-5EC31-0AA0
Circuit breaker 3VA5 UL frame 250 breaking capacity class M 35kA @ 480 V 3-pole, line protection TM230, FTAM, In=100A overload protection Ir=100A fixed short-circuit protection Ii= …
-
3VA5210-5EC31-1AA0
CIRCUIT BREAKER 3VA5 UL FRAME 250 BREAKING CAPACITY CLASS M 35KA @ 480 V 3-POLE, LINE PROTECTION TM230, FTAM, IN=100A OVERLOAD PROTECTION IR=100A FIXED SHORT CIRCUIT PROTECTION I …
-
3VA5210-5EC61-0AA0
Circuit breaker 3VA5 UL Frame 250 breaking capacity class M 35 kA @ 480 V 2-pole, line protection TM230, FTAM, In=100 A overload protection Ir=100 A permanently set short-circuit p …
-
3VA5210-5ED31-0AA0
Circuit breaker 3VA5 UL Frame 250 breaking capacity class M 35 kA @ 480 V 3-pole, line protection TM210, FTFM, In=100 A overload protection Ir=100 A permanently set short-circuit p …
-
3VA5210-5ED31-1AA0
CIRCUIT BREAKER 3VA5 UL FRAME 250 BREAKING CAPACITY CLASS M 35KA @ 480 V 3-POLE, LINE PROTECTION TM210, FTFM, IN=100A OVERLOAD PROTECTION IR=100A FIXED SHORT CIRCUIT PROTECTION I …
-
3VA5210-6EC31-0AA0
Circuit breaker 3VA5 UL Frame 250 breaking capacity class H 65 kA @ 480 V 3-pole, line protection TM230, FTAM, In=100 A overload protection Ir=100 A permanently set short-circuit p …
-
3VA5210-6ED31-0AA0
Circuit breaker 3VA5 UL Frame 250 breaking capacity class H 65 kA @ 480 V 3-pole, line protection TM210, FTFM, In=100 A overload protection Ir=100 A permanently set short-circuit p …
-
3VA5212-5EC31-0AA0
Circuit breaker 3VA5 UL frame 250 breaking capacity class M 35kA @ 480 V 3-pole, line protection TM230, FTAM, In=125A overload protection Ir=125A fixed short-circuit protection Ii= …
-
3VA5212-5EF31-0AA0
Circuit breaker 3VA5 UL Frame 250 breaking capacity class M 35 kA @ 480 V 3-pole, line protection TM240, ATAM, In=125 A overload protection Ir=100 A...125 A short-circuit protectio …
-
3VA5212-5GF41-0AA0
Circuit breaker 3VA5 UL frame 250 breaking capacity class M 35kA @ 480 V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=100A...125A short-circuit protection Ii …