3AH3305-8NE40-0EA2 SIEMENS ⍾ 3AH33058NE400EA2
Vacuum circuit breaker 36 kV Distance between pole centers 350 mm 31.5 kA 4000 A operating mechanism EK Secondary equipment: switching cycle counter Switch case message 2 position switches f. signaling "Closing spring tensioned", Switch-on solenoid with varistor circuit in secondary circuit 2 shunt releases Voltage of the switch-on solenoid 110 V DC Voltage of the 1st release 110 V DC without 2nd trigger without 3rd trigger Voltage of the operating mechanism 110 V DC auxiliary switch 6 NO+6 NC Secondary connection 64-pole connector Nameplate and operating instructions in English, Frequency of the operating voltage 50 Hz
Related in 3AH ⍾ Page 2
-
3AH4305-4TK88-8KC2-Z E24
+E25 +F20 +F30 VACUUM CIRCUIT-BREAKER 36KV F.120.000 MECH.OPERATING CYCLES POLE-CENTRE DISTANCE 350MM 31.5KA 2000A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING …
-
3AH4305-6ME40-0EB2-Z A31
VACUUM CIRCUIT-BREAKER 36KV F.120.000 MECH.OPERATING CYCLES POLE-CENTRE DISTANCE 350MM 31.5KA 2500A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING …
-
3AH4305-6RE44-0ED2
Vacuum Circuit-Breaker 36kV f.120.000 mech.operating cycles pole-centre distance 350mm 31.5kA 2500A operatg.mechanis.EK secondary equipment: operating cycle counter breaker trippin …
-
3AH4305-6RF55-0FC2
VACUUM CIRCUIT-BREAKER 36KV F.120.000 MECH.OPERATING CYCLES POLE-CENTRE DISTANCE 350MM 31.5KA 2500A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING …
-
3AH4305-6RJ77-0JC2-Z F20
+F30 Vacuum Circuit-Breaker 36kV f.120.000 mech.operating cycles pole-centre distance 350mm 31.5kA 2500A operatg.mechanis.EK secondary equipment: operating cycle counter breaker trippin …
-
3AH4305-6RK88-0KE2-Z A26
+F20 Vacuum circuit breaker 36 kV for 120,000 mech. switching cycles Distance between pole centers 350 mm 31.5 kA 2500 A operating mechanism EK Secondary equipment: switching cycle coun …
-
3AH4305-6RV88-0KD2
Vacuum Circuit-Breaker 36kV f.120.000 mech.operating cycles pole-centre distance 350mm 31.5kA 2500A operatg.mechanis.EK secondary equipment: operating cycle counter breaker trippin …
-
3AH4305-7RK88-0KD2-Z E19
+E25 +F20 +F30 +Y09 Vacuum circuit breaker 36 kV for 120,000 mech. switching cycles Distance between pole centers 350 mm 31.5 kA 3150 A operating mechanism EK Secondary equipment: switching cycle coun …
-
3AH5103-1
Vacuum circuit breaker 12 kV; Distance between pole centers; 160 mm 20 kA 800 A; with 1st shunt release; With switch-on solenoid 220 V; DC; Voltage of the 1st release 220; V DC; Wi …
-
3AH5103-1MF50-1FB9-Z F20
+F30 +R1G Vacuum Circuit-Breaker 12kV pole-centre distance 160mm 20kA 800A with 1st shunt release with varistor circuitry with closing solenoid DC 220V voltage of 1st shunt release DC 220V w …
-
3AH5133-1MF50-5FJ2-Z E13
VACUUM CIRCUIT-BREAKER 12KV POLE-CENTRE DISTANCE 210MM 20KA 800A WITH 1ST SHUNT RELEASE WITH VARISTOR CIRCUITRY DC >= 60V WITH CLOSING SOLENOID DC 220V, VOLTAGE OF 1ST SHUNT RELEA …
-
3AH5135-2ME40-1EH2
VACUUM CIRCUIT-BREAKER 12KV POLE-CENTRE DISTANCE 210MM 31.5KA 1250A WITH 1ST SHUNT RELEASE WITH VARISTOR CIRCUITRY DC >= 60V WITH CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST SHUNT REL …